18-29-607.2 Hot or tempered water supply to fixtures.

The developed length of hot or tempered water piping, from the source of hot water to the fixtures that require hot or tempered water, shall not exceed 50 feet (15 240 mm). Recirculating system piping and heat-traced piping shall be considered to be sources of hot or tempered water. (Amend Coun. J. 10-14-21, p. 37722, Art. VI, § 27)