Chapter 6 — Water Supply and Distribution (18-29-601 et seq.)
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026), Chicago, IL · 185 sections. Independent public-information project, not the official City of Chicago website.
- § 18-29-601.1 — Scope
- § 18-29-601.2 — Inspections and notices
- § 18-29-601.3 — Access for inspections
- § 18-29-601.4 — Solar energy utilization
- § 18-29-602.1 — General
- § 18-29-602.1.1 — Obligations of water consumers
- § 18-29-602.1.2 — Obligations of water consumers - Private water mains on private property
- § 18-29-602.2 — Potable water required
- § 18-29-602.4 — Reserve water supply
- § 18-29-602.4.1 — Installation of line valves or taps
- § 18-29-602.4.2 — Dual meter settings
- § 18-29-603.1 — Size of water service pipe and water meter
- § 18-29-603.1.1 — Meter spreader connection
- § 18-29-603.1.2 — Water service for fire protection systems
- § 18-29-603.1.3 — Permit required
- § 18-29-603.2 — Separation of water service and building sewer/drain
- § 18-29-603.2.1 — Water supply systems installed near a sewer structure
- § 18-29-603.2.3 — Backfill
- § 18-29-603.3 — Metered service
- § 18-29-603.3.1 — Authority
- § 18-29-603.3.2 — Connection to metered service
- § 18-29-603.3.3 — Licensed and bonded contractor
- § 18-29-603.3.4 — Location
- § 18-29-603.3.5 — Construction of meter vaults
- § 18-29-603.3.6 — Installation of taps
- § 18-29-603.3.7 — Plans accompany permit application
- § 18-29-603.3.8 — Notification of wrecking buildings for terminating water service
- § 18-29-604.1 — General
- § 18-29-604.2 — System interconnection
- § 18-29-604.3 — Water distribution system design criteria
- § 18-29-604.4 — Maximum flow and water consumption
- § 18-29-604.4.1 — WaterSense compliance
- § 18-29-604.5 — Size of fixture supply
- § 18-29-604.5.1 — Minimum size
- § 18-29-604.6 — Variable street pressures
- § 18-29-604.7 — Inadequate water pressure
- § 18-29-604.8 — Water pressure reducing valve or regulator
- § 18-29-604.8.2 — Repair and removal
- § 18-29-604.9 — Water hammer
- § 18-29-604.9.1 — Air chambers
- § 18-29-604.10 — Size of water supply pipes
- § 18-29-604.10.1 — Minimum sizes of branch distributing pipes for fixtures and appliances
- § 18-29-604.10.1.1 — Demand load
- § 18-29-604.10.1.2 — Size of piping
- § 18-29-604.10.1.3 — Available pressure
- § 18-29-604.10.2 — Procedures for calculating sizing
- § 18-29-604.11 — Individual pressure balancing in-line valves for individual fixture fittings
- § 18-29-605.1 — Water compatibility
- § 18-29-605.2 — Soil and ground water
- § 18-29-605.3 — Lead content of water supply pipe and fittings
- § 18-29-605.3.1 — Lead content of drinking water pipe and fittings
- § 18-29-605.4 — Water service pipe
- § 18-29-605.4.1 — Materials for supply pipes and fittings
- § 18-29-605.5 — Water distribution pipe
- § 18-29-605.6 — Fittings
- § 18-29-605.7 — Valves
- § 18-29-605.8 — Manufactured pipe nipples
- § 18-29-605.9 — Prohibited joints and connections
- § 18-29-605.10 — Flexible water connectors
- § 18-29-605.12 — Brass
- § 18-29-605.12.1 — Brazed joints
- § 18-29-605.12.2 — Mechanical joints
- § 18-29-605.12.3 — Threaded joints
- § 18-29-605.12.4 — Welded joints
- § 18-29-605.13 — Gray iron and ductile iron joints
- § 18-29-605.14.4 — Threaded joints
- § 18-29-605.14.5 — Welded joints
- § 18-29-605.15 — Copper tubing
- § 18-29-605.15.1 — Brazed joints
- § 18-29-605.15.2 — Flared joints
- § 18-29-605.15.3 — Grooved and shouldered mechanical joints
- § 18-29-605.15.4 — Mechanical joints
- § 18-29-605.15.5 — Press-connect joints
- § 18-29-605.15.6 — Soldered joints
- § 18-29-605.15.7 — Push-fit fitting joints
- § 18-29-605.16 — CPVC plastic
- § 18-29-605.16.1 — Mechanical joints
- § 18-29-605.16.2 — Solvent cementing
- § 18-29-605.16.3 — Threaded joints
- § 18-29-605.17 — Steel
- § 18-29-605.17.1 — Threaded joints
- § 18-29-605.17.2 — Mechanical joints
- § 18-29-605.21 — Joints between different materials
- § 18-29-605.21.1 — Copper or copper-alloy tubing to galvanized steel pipe
- § 18-29-605.22 — Protection for pipes and fixtures
- § 18-29-605.23 — Hydrants and non-freeze hydrants protection
- § 18-29-605.24 — Water supply pipe protection
- § 18-29-605.25 — Refrigerant condensers
- § 18-29-605.26 — Dead-ends prohibited
- § 18-29-605.27 — Air conditioning and refrigeration systems
- § 18-29-605.28 — Permissible exceptions
- § 18-29-606.1 — Location of full-open valves
- § 18-29-606.2 — Location of shutoff valves
- § 18-29-606.3 — Access to valves
- § 18-29-606.4 — Valve identification
- § 18-29-606.5 — Water pressure booster systems
- § 18-29-606.5.1 — Hydropneumatic system, booster pump system, gravity tank
- § 18-29-606.5.1.1 — Requirements
- § 18-29-606.5.1.1.1 — Pressure relief valve
- § 18-29-606.5.1.1.2 — Compression tank
- § 18-29-606.5.1.1.3 — Sludge drain pipe
- § 18-29-606.5.1.2 — Booster pump system
- § 18-29-606.5.1.2.1 — Gravity tanks
- § 18-29-606.5.1.2.2 — Total pressure
- § 18-29-606.5.1.2.3 — Low pressure cutoff
- § 18-29-606.5.2 — Surge tank for pumps
- § 18-29-606.5.3 — Check valves required
- § 18-29-606.5.3.1 — Approval required
- § 18-29-606.5.4 — Equipment required for tanks receiving city water
- § 18-29-606.5.4.1 — Sludge drain pipe
- § 18-29-606.5.4.2 — Size
- § 18-29-606.5.4.3 — Covers and support
- § 18-29-606.5.5 — Recycling system for vehicle wash installations
- § 18-29-606.5.6 — Potable water inlet control and location
- § 18-29-606.5.7 — Tank drain pipes
- § 18-29-606.5.8 — Prohibited location of potable supply tanks
- § 18-29-606.5.9 — Pressure relief valve requirements
- § 18-29-606.5.10 — Pressure relief valves for hydropneumatic tanks
- § 18-29-606.6 — Test of distribution pipes
- § 18-29-607.1 — Where required
- § 18-29-607.1.1 — Temperature limiting means
- § 18-29-607.1.2 — Tempered water temperature control
- § 18-29-607.2 — Hot or tempered water supply to fixtures
- § 18-29-607.2.1 — Circulation systems and heat trace systems for maintaining heated water temperature in distribution systems
- § 18-29-607.2.1.1 — Pump controls for hot water storage system
- § 18-29-607.2.1.2 — Demand recirculation controls for distribution systems
- § 18-29-607.2.2 — Piping for recirculation systems having temperature-actuated mixing valves
- § 18-29-607.3 — Thermal expansion control
- § 18-29-607.4 — Flow of hot water to fixtures
- § 18-29-607.5 — Insulation of piping
- § 18-29-607.6 — Expansion joints
- § 18-29-608.1 — General
- § 18-29-608.2 — Plumbing fixtures
- § 18-29-608.3 — Water supply pipes
- § 18-29-608.3.1 — Special equipment, water supply protection
- § 18-29-608.5 — Secondary water
- § 18-29-608.6 — Prohibited use of secondary water
- § 18-29-608.6.1 — Private water supplies
- § 18-29-608.7 — Stop-and-waste valves prohibited
- § 18-29-608.8 — Identification of potable and nonpotable water
- § 18-29-608.9 — Re-utilization prohibited
- § 18-29-608.10 — Reuse of piping
- § 18-29-608.11 — Painting of water tanks
- § 18-29-608.12 — Pumps and other appliances
- § 18-29-608.13 — Backflow protection
- § 18-29-608.13.1 — Air gap
- § 18-29-608.13.2 — Reduced pressure principle backflow preventers
- § 18-29-608.13.3 — Backflow preventer with intermediate atmospheric vent
- § 18-29-608.13.4 — Barometric loop
- § 18-29-608.13.5 — Atmospheric-type vacuum breakers
- § 18-29-608.13.6 — Double check-valve assemblies
- § 18-29-608.14 — Location of backflow preventers
- § 18-29-608.15 — Protection of potable water outlets
- § 18-29-608.16 — Connections to the potable water system
- § 18-29-608.16.1 — Beverage carbonator
- § 18-29-608.16.1.1 — Backflow preventer
- § 18-29-608.16.2 — Steam boilers
- § 18-29-608.16.2.1 — High-pressure
- § 18-29-608.16.2.2 — Low-pressure
- § 18-29-608.16.3 — Connections to automatic fire sprinkler systems and standpipe systems
- § 18-29-608.16.4 — Fire protection equipment, risers, standpipes, tanks to be drained and flushed
- § 18-29-608.16.5 — Fire-extinguishing equipment cross-connection
- § 18-29-608.16.5.1 — Prohibitions
- § 18-29-608.16.6 — Chemical or petroleum pressure vessels
- § 18-29-608.16.6.1 — Chemical or petroleum pressure vessels
- § 18-29-608.16.6.2 — Water flushing or cooling
- § 18-29-608.16.6.3 — Chemical, contaminated water, or sewage lines or vessels
- § 18-29-608.16.8 — Portable cleaning equipment
- § 18-29-608.16.9 — Dental pump equipment
- § 18-29-608.17 — Private water supplies
- § 18-29-608.17.1 — Well locations
- § 18-29-608.17.1.1 — Distances
- § 18-29-608.17.1.2 — Direct connections
- § 18-29-609.1 — General
- § 18-29-609.1.1 — Where required
- § 18-29-609.2 — Water service
- § 18-29-609.3 — Hot water
- § 18-29-609.4 — Vacuum breaker installation
- § 18-29-609.5 — Prohibited water closet and clinical sink supply
- § 18-29-609.6 — Clinical, hydrotherapeutic and radiological equipment
- § 18-29-609.7 — Condensate drain trap seal
- § 18-29-609.8 — Valve leakage diverter
- § 18-29-610.1 — Scope
- § 18-29-611.1 — Design
- § 18-29-611.2 — Reverse osmosis systems
