§ 8-1-4-304.4 — Amendment to Section 304.4 of the UMC

Salina Code, City of Salina, Kansas (Codified through Ordinance No. 26-11299 adopted August 24, 2026. (Supp. No. 19)) · Salina Municipal Code § 8-1-4-304.4

Corpus is an independent public-information project, not the official City of Salina website. Stable reference: corpuslaw.us/code/82641fea-f964-42be-a9f1-8117dff365c3

Sec. 8-1-4-304.4. - Amendment to Section 304.4 of the UMC.

Section 304.4 of the UMC is amended to read as follows: Sec. 304.4 Appliances in Attics and Under-Floor Spaces. An attic or under floor space in which an appliance is installed shall be accessible through an opening and passageway not less than 22 inches by 30 inches (559 mm by 762 mm). 304.4.1 Length of Passageway. Where the height of the passageway is less than 6 feet (1829 mm), the distance from the passageway access to the appliance shall not exceed 20 feet (6096 mm) measured along the center line of the passageway. [NFPA 54:9.5.1.1] 304.4.2 Width of Passageway. The passageway shall be unobstructed and shall have solid flooring not less than twenty-four inches (610 mm) wide from the entrance opening to the appliance. [NFPA 54:9.5.1.2] 304.4.3 Work Platform. A level working platform not less than thirty inches by thirty inches (762 mm by 762 mm) shall be provided in front of the service side of the appliance. [NFPA 54:9.5.2] Exception: A working platform need not be provided when the furnace is capable of being serviced from the required access opening. The furnace service side shall not exceed 12 inches (305 mm) from the access opening. 304.4.4 Lighting and Convenience Outlet. A permanent 120V receptacle outlet and a lighting fixture shall be installed near the appliance. The switch controlling the lighting fixture shall be located at the entrance to the passageway. [NFPA 54:9.5.3] Exception: Neither an outlet nor a light shall be required for furnaces installed above a lay-in ceiling when tiles immediately adjacent to the furnace can be removed.

(Ord. No. 25-11269, § 1, 12-8-25)

Ask a question about Salina law

Corpus searches the Salina sections it holds and shows the ones that match, with their citations. Free, no sign-in.