Sec. 8-1-4-802.3.6. - Amendment to Section 802.3.6 of the UMC.

Section 802.3.6 of the UMC is amended to read as follows: Sec. 802.3.6 Above-Ceiling or Nonducted Air Handling System. Where a venting system passes through an above-ceiling air space or other nonducted portion of an air-handling system, it shall conform to one of the following requirements: 1. The venting system shall be a listed special gas vent, other system serving a Category III or Category IV appliance, or other positive pressure vent, with joints sealed in accordance with the appliance or vent manufacturer's instructions. 2. The vent system shall be installed such that no fittings or joints between sections are installed in the above-ceiling space. 3. The venting system shall be installed in a conduit or enclosure with joints between the interior of the enclosure and the ceiling space sealed. [NFPA 54:12.4.5.2] Exception: The change-out of an existing 80% efficiency above-ceiling furnace is allowed when the change-out is like-for-like.

(Ord. No. 25-11269, § 1, 12-8-25)