§ 405 — GREASE AND GRIT TRAPS

Comprehensive Development Regulations for the City of Flowood; partial · Flowood Development Regulations § 405

Corpus is an independent public-information project, not the official City of Flowood website. Stable reference: corpuslaw.us/code/6be3b724-c16d-44cd-978f-62c6bfcb53fc

SECTION 405 GREASE AND GRIT TRAPS

405.1 Discharge from Fats Oils and Greases (FOG) are governed by the Flowood Grease Interceptor Ordinance. The purpose of this ordinance is to:

a. Prevent the introduction of wastewater containing oil and grease and/or solids in amounts which may cause stoppages or obstruction of flow, or in any other way prevent or inhibit operation of the sanitary sewer collection system.

b. Protect the environment, and the health, safety, and welfare of the public and the City of Flowood.

c. Set forth basic requirements for the application of grease traps, grit traps, interceptors, and separators.

405.2 General Requirements:

a. Commercial establishments that generate grease and/or grit will be required to have traps, interceptors and/or separators.

b. Grease or grit trap/interceptor must be sized in accordance to plumbing code or engineer design and the minimum shall be 750 gallons, whichever is greater.

c. Secondary interceptors for car washes with a pressure washer must be sized in accordance to plumbing code or engineer design and the minimum shall be 750 gallons, whichever is greater.

d. Secondary interceptors for carwashes without a pressure washer must be sized in accordance to plumbing code or engineer design and the minimum shall be 500 gallons, whichever is greater.

e. Primary and/or secondary traps shall be interceptor style, such as rectangular with a baffling system. No septic tank configuration or round tanks will be allowed.

f. Traps shall be designed and constructed to prevent fats, oils, or grease from entering the sanitary sewer in concentrations greater than 100 mg/l (or as local limits are amended).

g. Traps shall be easily accessible for cleaning, maintenance, and inspection.

h. Sample port/well will be required for al200l grease and grit traps/interceptors on the discharge side and be accessible for sampling.

i. Plumbing plan must show how the interior building lines will be routed to the grease trap/interceptor.

j. Sanitary sewer/Utility plan must show how grease or grit trap/interceptor will connect to the existing sanitary sewer system.

k. Details of grease and grit trap/interceptor must be shown on plans, provide model type and size.

l. Detail of sample port/well must be shown on plans.

m. Commercial/industrial establishments that generate wastewater from processes to be discharged to sanitary sewer will require prior approval and possible pretreatment.

n. Listed above are just a portion of the requirements of grease and grit traps that are to be installed in the City. For additional and more detailed information, see the Flowood Grease Interceptor Ordinance. Should there be a discrepancy between the information shown herein and the Grease Interceptor Ordinance, the Grease Interceptor Ordinance shall govern.