§ 410 — CULVERT MATERIALS & INSTALLATION
Comprehensive Development Regulations for the City of Flowood; partial · Flowood Development Regulations § 410
Corpus is an independent public-information project, not the official City of Flowood website. Stable reference: corpuslaw.us/code/3a25340d-f37c-4f31-a5f7-4b48a2bdcc73
SECTION 410 CULVERT MATERIALS & INSTALLATION
410.1 Concrete pipe materials
a. All concrete pipes shall conform to ASTM C-76 and be Class III minimum, standard
strength, bell and spigot or tongue and groove.
b. All Portland cement shall conform to ASTM C150, Type 1.
c. All sand shall conform to ASTM C-33.
d. All mortar shall consist of one part cement, two parts sand, and 15 percent lime (weight of cement).
e. Rubber gaskets shall be used on all round concrete pipes and conform to the requirements of ASTM C- 443.
f. Filter fabric shall be laid around all RCP pipe joints and the joints located at all drainage structure/pipe connections.
g. Geotextile fabric shall be Type V as specified in the Mississippi Standard Specifications for Road and Bridge Construction, Latest Edition.
410.2 Concrete pipe installation
a. Any materials delivered to a job site defective, damaged, or not meeting code, shall be rejected by the city, and shall not be used for construction, and shall be removed from the job site at once. If installed prior to detecting substandard material, it shall be removed, and approved material installed at the developer's expense.
b. All concrete pipe, catch basins, curb inlets and headwalls shall be installed in strict accordance with the manufacturer's recommendations and/or all applicable provisions of the Mississippi Standard Specifications for Road and Bridge Construction, Latest Edition.
c. All pipes shall be laid to alignment and grade with the use of a laser.
d. No more trenches shall be opened than can effectively utilized in a day. Excavations to be left open during non-working hours shall be kept to a minimum. Such openings shall be adequately protected or marked to prevent injury.
e. All lifting holes shall be plugged with and approved manufactured lifting hold plug and covered with Type V Geotextile Fabric.
f. Rubber gaskets shall be used on all round concrete pipe joints and conform to the requirements of ASTM C-443. All joints are to be wrapped in a Type V Geotextile Fabric, 24-inch, minimum in width.
g. Filter fabric shall be laid around all RCP pipe joints and the joints located at all drainage structure/pipe connections.
h. Mortar for connections to other drainage structures shall be composed of one part of volume of Portland Cement and two parts to mortar sand. Just enough clean, potable
water will be added to make the mix of such consistency that it can be easily handled and spread with a trowel. Any mortar that is not used within 45 minutes after water has been added will be wasted. Retempering of mortar will not be permitted.
i. Backfilling shall be as follows:
1. The contractor shall do trench bracing, sheathing or shoring as necessary to perform and protect the excavation and shall remove such materials as backfill progresses. The backfill material shall be as approved by the engineer.
2. Great care shall be used to obtain thorough compaction under the haunches and along the sides and to the top of the pipe.
3. In areas under streets, walks, parking lots, or curbs, the backfill shall be placed in loose lifts, not exceeding eight inches in depth and compacted to 98 percent standard Proctor density by ASTM D-698 using mechanical devices designed for that purpose.
4. In all other areas the backfill may be placed in 12-inch; loose lifts compacted to 90 percent standard Proctor density by ASTM D-698.
410.3 High-Performance polypropylene pipe materials
a. Twelve through 30-inch (300 to 750 mm) pipe shall have a smooth interior and annular exterior corrugations and meet or exceed ASTM F2736 and AASHTO M330.
b. Thirty-six through 60-inch (900 to 1,500 mm) pipe shall have a smooth interior and annular exterior corrugations and meet or exceed ASTM F2881 and AASHTO M330.
c. Pipe shall be joined with a gasketed integral bell & spigot joint meeting the requirements of ASTM F2736 or F2881, for the respective diameters.
d. Twelve through 60-inch (300 to 1,500 mm) shall be watertight according to the requirements of ASTM D3212. Spigots shall have gaskets meeting the requirements of ASTM F477. The gasket shall be installed by the pipe manufacturer and covered with a removable, protective wrap to ensure the gasket is free from debris. A joint lubricant available from the manufacturer shall be used on the gasket and bell during assembly.
e. Fittings shall conform to ASTM F2736, ASTM F2881 and AASHTO M330, for the respective diameters. Bell & spigot connections shall utilize a spun-on, welded or integral bell and spigot with gaskets meeting ASTM F477. Bell & spigot fittings joint shall meet the watertight joint performance requirements of ASTM D3212. Corrugated couplings shall be split collar, engaging at least two full corrugations.
f. Polypropylene compound for pipe and fitting production shall be impact modified copolymer meeting the material requirements of ASTM F2736, Section 4, ASTM F2881, Section 5 and AASHTO M330, Section 6.1, for the respective diameters.
410.4 High-Performance polypropylene pipe installation
a. Any materials delivered to a job site defective, damaged, or not meeting code, shall be rejected by the city, and shall not be used for construction, and shall be removed from the job site at once. If installed prior to detecting substandard material, it shall be removed, and approved material installed at the developer's expense.
b. All pipes shall be laid to alignment and grade with the use of a laser.
c. No more trenches shall be opened than can effectively utilized in a day. Excavations to be left open during non-working hours shall be kept to a minimum. Such openings shall be adequately protected or marked to prevent injury.
d. Installation shall be in accordance with ASTM D2321, and manufacturer recommended installation guidelines, with the exception that minimum cover in all areas for 12- through 48-inch (300 to 1200 mm) diameters shall be one foot. (0.3 m) and for 60-inch (1500 mm) diameters, the minimum cover shall be two feet. (0.6 m) in single run applications. Backfill for minimum cover situations shall consist of Class 1, Class 2 (minimum 90 percent SPD) or Class 3 (minimum 95 percent) material as defined in ASTM D2321.
e. Class IV material as defined by ASTM D2321 will not be allowed as bedding or initial backfill material.
f. Note: If any conflicts arise between these specifications and the manufacturer's recommendations or ASTM D2321, the more stringent requirements shall govern.
410.5 Storm Drain Structures (Curb, Grate Inlets, Junction Boxes, etc.)
a. All storm drain structures shall be installed per the City’s standard details and the latest edition of the MDOT Standard Specifications
b. Storm drain structures located in public or private ROW in a development shall be precast or poured in place.
c. Storm drain structures that are located outside the street ROW on private commercial or industrial lots may be Nyloplast PVC inlets or equal product rated for the proposed application. In such cases, these structures shall be maintained by the owner in perpetuity.
d. Junction boxes shall be placed at all changes in pipe size, alignment, and grade except where storm inlets or catch basins may be beneficial.
e. All drainage structures shall allow for access to the storm drainage system with a grate or manhole ring and cover capable of being removed. The cover shall be flush with the final grade and provide sufficient opening for cleaning, maintenance and inspection.
f. Storm drain culverts shall be cut flush with the walls of the drainage structure.
410.6 Precast Structures
a. Concrete shall have compressive strength of 4,000 psi at 28 days.
b. Precast structures shall conform to the City’s standard details and shall meet the requirements of ASTM C 913 and MDOT Standards Specifications.
410.7 Poured in place Structures
a. Concrete materials shall be as required in the latest edition of the MDOT Standard Specifications.
b. Form material shall be as required in the latest edition of the MDOT Standard Specifications.
c. Provide ¾” chamfer on all exposed corners.
d. Reinforcing bars shall conform to ASTM A 615, Grade 60
e. Welded wire fabric shall conform to ASTM A 185 & ASTM A 82. All joints shall be sealed with flexible plastic gaskets for joint conduit, AASHTO Specification M-198 or MDOT Specifications.
f. All joints shall be sealed with non-shrink grout on the inside and outside of the structure.
g. The construction of poured in place structures shall be in compliance with the City’s standard details and MDOT Standard Specifications.
410.8 Storm drain castings
a. Storm Drain Castings shall conform to the City’s standard details and shall have a minimum opening of 24” and shall manufactured and tested in accordance with AASHTO M-306-07, ASTM standard A 48/A 48M, Standard Specification for Gray Iron Castings.
b. Storm drain castings shall read “DUMP NO WASTE – DRAINS TO RIVER” or similar.