25.06.780 IRC Section 1502.4.2 Amended; Duct Installation.

Section 1502.4.2 of the 2021 International Residential Code is hereby amended to read as follows: Exhaust ducts shall be supported at intervals not to exceed 10 feet and be secured in place. The insert end of the duct shall extend into the adjoining duct or fitting in the direction of airflow. Ducts shall not be joined with screws or similar fasteners that protrude into the inside of the duct. Where dryer exhaust ducts are enclosed in wall or ceiling cavities, such cavities shall allow the installation of the duct without deformation. Exhaust ducts shall be sealed in accordance with Section M1601.4.1. (: Ord. 20526 §97, August 21, 2017).

(Ord. 21815 §71; December 15, 2025; Ord. 21113 §48; August 23, 2021)