25.06.870 IRC Section M1701.1 Amended; Combustion Air.

Section M1701.1 of the International Residential Code is amended to read as follows: Combustion air shall be provided to all fuel burning appliances according to Section 304 of the 2021 International Fuel Gas Code. Air handling systems or ducting installed in newly constructed residences shall bring in outside air when furnaces or water heating appliances using interior combustion air and/or open face fireplaces are installed. The outside air shall be 4 inch minimum round but not less than 50% of flue size of vents serving furnaces and/or water heaters. The outside air duct may be run in insulated flex piping but must terminate with galvanized metal within 6 feet of the appliances served or into the return air system at a point where interior air is directly mingled with the outside air. Hoods serving outside air ducts must be installed 12 inches minimum above grade. Exception: Existing Building: When fuel-burning appliances are installed in an existing building containing other fuel-burning appliances, the room or space shall be provided combustion air as required by this chapter for all fuel-burning appliances contained therein. Additional floor area can be used for combustion air requirements of a replacement furnace when all of the following conditions are met: (1) 1. The structure is a single-family dwelling. (2) 2. The communicating high-low combustion grills between the mechanical space and adjoining areas must constitute at least 50% of the required cubic feet for combustion air for the total BTU’s in the space. (3) 3. A blower type furnace is being installed. (4) 4. A grill equivalent to one square inch free air per 4000 BTU input rating of all appliances shall be installed on the supply duct or plenum. (5) 5. The grill shall not have shutters and shall be labeled with at least 1/2-inch letters of metal, plastic, or other approved materials and read: “Combustion Air Grill--Do Not Cover. If covered, may cause illness or death.” (6) 6. The combustion grill cannot be on the plenum or supply duct, within the furnace room, if the furnace room area is less than 25% of the required cubic feet. (: Ord. 20526 §109, August 21, 2017).

(Ord. 21815 §84; December 15, 2025; Ord. 21113 §67; August 23, 2021)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.