25.06.800 IRC Section M1503.6 Amended; Makeup Air Required.
Section M1503.6 of the 2021 International Residential Code is amended to read as follows: M1503.6 Makeup air required. Residential kitchen exhaust may exceed 400 cfm provided makeup air is provided into the structure. The makeup air shall be controlled by a motorized damper that is electrically interlocked to open with operation of the kitchen exhaust fan. The makeup air shall be conditioned to within 10 degrees F of the space designed temperature during the winter heating mode. The makeup air may be conditioned by circulation with a forced air furnace system or by other means approved by the Building Official. Kitchen exhaust exceeding 400 cfm will not require make up air in homes with no open flues or use of interior combustion air. (: Ord. 20526 §99, August 21, 2017).
(Ord. 21815 §73; December 15, 2025; Ord. 21113 §50; August 23, 2021)