25.06.865 IRC Section M1602.2 Amended; Return Air Openings.
Section M1602.2 of the 2021 International Residential Code is amended to read as follows: Outdoor and return air for a forced-air heating or cooling system shall not be taken from the following locations: (1) 1. Closer than 10 feet (3048 mm) to an appliance open combustion chamber, draft hood, or vent outlet, a vent opening from a plumbing drainage system, or the discharge outlet of an exhaust fan, unless the outlet is 3 feet (914 mm) above the outside air inlet. (2) 2. Where flammable vapors are present; or where located less than 10 feet (3048 mm) above the surface of any abutting public way or driveway; or where located at grade level by a sidewalk, street, alley, or driveway. (3) 3. A room or space, the volume of which is less than 25 percent of the entire volume served by the system. Where connected by a permanent opening having an area sized in accordance with ACCA Manual D, adjoining rooms or spaces shall be considered as a single room or space for the purpose of determining the volume of the rooms or spaces. (4) 4. A bathroom, toilet room, garage, mechanical room, boiler room, furnace room, unconditioned attic, or other dwelling unit. Exception: A bathroom large in comparison may have a return air inlet. Exception: Where return air intakes are located not less than 10 feet from cooking appliances and serve the kitchen area only, taking return air from a kitchen shall not be prohibited. Exception: Dedicated forced-air systems serving only a garage shall not be prohibited from obtaining return air from the garage. (5) 5. A room or space containing a fuel-burning appliance where such room or space serves as the sole source of return air. Exceptions: (1) 1. The fuel-burning appliance is a direct-vent appliance not requiring a vent in accordance with Section M1801.1 or Chapter 24 of the 2021 International Residential Code. (2) 2. The room or space complies with the following requirements: (1) 2.1 The return air shall be taken from a room or space having a volume exceeding 1 cubic foot for each 10 Btu/h (9.6 L/W) of combined input rating of all fuel-burning appliances therein. (2) 2.2 The volume of supply air discharged back into the same space shall be approximately equal to the volume of return air taken from the space. (3) 2.3 Return-air inlets shall not be located within 10 feet (3048 mm) of a draft hood in the same room or space or the combustion chamber of any atmospheric-burner appliance in the same room or space. (3) 3. Rooms or spaces containing solid-fuel burning appliances, if return-air inlets are located not less than 10 feet (3048 mm) from the firebox of those appliances. (6) 6. An unconditioned crawl space by means of direct connection to the return side of a forced air system. Transfer openings in the crawl space enclosure shall not be prohibited. (: Ord. 20526 §108, August 21, 2017).
(Ord. 21815 §83; December 15, 2025; Ord. 21113 §66; August 23, 2021)
Ask a question about Lincoln law
Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.