§ 25.06.825 — IRC Table M1601.1.1 Amended; Duct Construction Minimum Sheet Metal Thickness for Single Dwelling Units

Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 25.06.825

Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/40825936-5e75-4a22-a70c-ebad536433da

25.06.825 IRC Table M1601.1.1 Amended; Duct Construction Minimum Sheet Metal Thickness for Single Dwelling Units.

Table M1601.1.1 of the International Residential Code is amended to read as follows: TABLE M1601.1.1 - Revised GAGES OF METAL DUCTS AND PLENUMS USED FOR HEATING OR COOLING DUCT SIZE | GALVANIZED 8 inches or less | 30 25 inches or less | 28 Over 25 inches | 26 For SI 1 inch = 25.4 mm (1) For duct gages and reinforcement requirements at static pressures of ½ inch, 1 inch, and 2 inches w.g., SMACNA Duct Construction Standard, Tables 2-1; 2-2 and 2-3 shall apply. ().

(Ord. 21113 §58; August 23, 2021)