Sec. 32-106. - Retention/detention pond design.

(a) The use of on-site detention/retention is required for the purpose of limiting the initial ten percent chance and major one percent chance storm runoff rates to historical levels. The type of design for each facility is subject to approval by the public works director. (b) Detention/retention pond facilities should be designed using a storage outflow relationship for the facility and a flood hydrograph routing procedure. For drainage basins smaller than one acre (.4047 ha), only retention ponds shall be used, detention or retention ponds may be used only for developments larger than one acre (.4047 ha). (c) For drainage basins larger than one acres (.4047 ha), a flood hydrograph routing method will be required. (d) Off-site runoff entering the development may occur in the drainage basin, and if this is the case, the analysis for the detention facility must take the flows into account. Off-site runoff should be analyzed as outlined herein. Off-site flows may be routed around the detention facility. However, entrance and exit points of storm runoff shall not be altered nor shall the post development peak flow exceed that historic peak flow for both one percent and ten percent chance rain events. (e) Those developments immediately adjacent to specific major drainage ways may have the detention requirements waived, subject to approval by the public works director. These areas must be thoroughly analyzed to show that no additional hazards will be created downstream and that downstream facilities (channels and/or detention/retention areas) can safely handle the increased flow rates or volumes. The city's stormwater management policy plan must be adhered to as well. This document requires the controlling and maintaining of major arroyos without damaging or affecting habitat, recreation, or open space values of these arroyos. (f) For any detention/retention facility design, a soils report shall be included. This report shall include but not be limited to soil boring logs, water table elevations and soil classifications. Sufficient and representative soil borings and tests shall be required to illustrate suitability for intended purpose and percolation characteristics. (g) Compliance with the city's stormwater management policy plan must be completed as a supplement to this design standard.

(Ord. No. 949, § 3.1F, 9-8-87; Ord. No. 1224, § 1, 3-18-91; Ord. No. 1929, §§ I, II, 8-5-02; Ord. No. 2187, 4-4-05)

Ask a question about Las Cruces law

Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.