For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 32-107 — On lot ponding; minimum pad elevations

Municipal Code of the City of Las Cruces, New Mexico (Supp. No. 34: codified through Ordinance No. 3114, adopted June 1, 2026) · Las Cruces Development Code § 32-107

Corpus is an independent public-information project, not the official City of Las Cruces website. Stable reference: corpuslaw.us/code/e5585c7c-4d5f-423f-b89e-b5787ca1db0c

Sec. 32-107. - On lot ponding; minimum pad elevations.

(a) One common manner in which post development runoff is controlled at or below pre-developed conditions is by way of on-lot ponding. When this approach is used there shall be restrictive covenants filed on record at the county to convey drainage requirements from seller to purchaser. When on-lot ponds are proposed a ponding icon shall be shown on all plats to indicate that the lot requires a pond and is the responsibility of the property owner to maintain. When on-lot ponding is proposed all lots shall have on-lot ponds and the percent credit shall be as follows: _____ Lot Size | % Credit ft 2 | ac | (m 2 ) | (ha) 0—8,300 | 0—0.1905 | (0—771.1) | 0—0.077 | 10 8,300—10,890 | 0.1906—0.250 | (771.2—1011.7) | 0.077—0.101 | 40 10,891—21,780 | 0.25—0.500 | (1011.7—2023) | 0.101—0.202 | 70 21,780—43,560 | 0.500—1.00 | (2023—4047) | 0.202—0.405 | 85 43,560+ | 1.00+ | (4047+) | 0.405+ | 100 Required ponding volume ≥ Credit * volume of lot ponds + volume of regional pond. Example: A ten-lot subdivision, with 0.2 acre lots, is determined to require 5,000 cubic feet of on-site volume. The engineer decides to place 600 cubic foot ponds on each lot. The regional pond will be required to hold 2,600 cubic feet. 5,000 - ((10 × 600) × 0.40) = 2,600 cubic feet required in regional pond. _____ (b) There will not be a minimum pad elevation for houses on lots in the five-mile ETZ. However, the grading plan must reflect pad elevations in relationship to the center of the street and have been stamped by a professional engineer licensed in the state which would certify the drainage plan as workable. (c) An area of two feet (0.609 m) out from the perimeter of the house must be a maximum two percent slope away from the pad of the structure. (d) All required ponding must be constructed at time of initial grading and must not be deferred until home construction is started and must not be altered during home construction without an engineered solution. (e) Many different ponding configurations can serve the foundation of detaining/retaining stormwater runoff. However, the city will limit the types of ponding areas that can be used and has further described them as follows: The type and design for each facility is subject to approval by the public works director and facilities director for type C pond. Three specific types of stormwater ponding areas will be permitted. The ownership, operation and maintenance responsibilities affect the design of the ponding area. Type "A" - Private Type "B" - City (drainage facility) Type "C" - City (park/dual use facility) The following parameters shall be used to guide the design of the three types of ponding facilities: _____ Element | Type A - Private | Type B - Drainage Facility | Type C - Park / Dual use Operation and maintenance | Private | City streets section | City parks section Size | Any | One acre minimum (0.405 ha) | 2.5 acres min. (1.01 ha) (or as directed by the minimum park size) Shape | Any | Rectangular preferred | Any Depth* | 18" minimum (0.457 m) 4 feet maximum (1.21 m)* | Same as type "A" | Same as type "A" Capacity | As needed to hold generated runoff | As needed to hold generated runoff plus an additional equivalent volume to provide a regional benefit | Same as type "A" Side slopes** | > 4:1 erosion control measures 2:1—3:1 stepped or grouted rock (slope stabilization) | 8:1 with natural slopes As steep as 4:1 when erosion control and access ramp are provided | Same as "B" Access | Optional | Must have improved access road with 8:1 maximum slope | Same as "B" Outlet | Must lead to drainage way, right of way (approval needed), or drainage easement | Same as type "A" | Same as type "A" Storage time | Must drain or percolate within 24 hours | Same as type "A" | Same as type "A" Landscape (when landscaped) | To be approved by the city landscape architect (see CLC stormwater management policy plan)*** | Low maintenance perimeter buffer to be approved by public works dept. | To be approved by the city landscape architect and parks department Fencing/railing | Optional - Unless hazard exists to those using public property | Required - Maintenance access gate also required | Same as type "A" Park fee credits | Case by case | None | Same as type "A" * Ponds deeper than four feet will be considered, when additional safety measures are taken. ** Sandy soil may require erosion protection with slopes flatter than 6:1, slopes steeper than 2:1 are not allowable. *** Nonresidential only. _____

(Ord. No. 949, § 3.1G, 9-8-87; Ord. No. 2187, 4-4-05)

Ask a question about Las Cruces law

Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.