§ 32-137 — Definitions
Municipal Code of the City of Las Cruces, New Mexico (Supp. No. 34: codified through Ordinance No. 3114, adopted June 1, 2026) · Las Cruces Development Code § 32-137
Corpus is an independent public-information project, not the official City of Las Cruces website. Stable reference: corpuslaw.us/code/a18e5920-4b10-46aa-a5d1-4677f0cef1e3
Sec. 32-137. - Definitions.
The following words, terms and phrases, when used in this division, shall have the meanings ascribed to them in this section and are part of the LCMC. Building/construction permit is an official document or certificate issued by the building official authorizing performance of a specific activity as defined in LCMC, chapter 30, article II, division 2, sections 30-171 through 30-722. City is the City of Las Cruces administrative government which encompasses all lands within the city's corporate boundary as designated by the present city limit location(s) plus the addition of lands outside city limits which are either leased or annexed. City of Las Cruces design values are listings of various engineering design values that amend the soil engineering properties in the IBC. When no site-specific soil properties have been identified through exploration and laboratory testing, these amended values shall be used. City project review is conducted to confirm that engineering principles are applied in conformance with both city design standards and the IBC. Collapse zone is the area around the wall or fence that would be affected by a potential wall or fence failure. If the wall or fence were to fail, it could fall straight out and could hit the ground similar to that of a falling tree. It is measured along the ground perpendicular to the wall or fence at a distance equal to the height of the wall or fence. Common yard wall. An artificially constructed barrier or structure along a property line between two or more properties owned by two or more separate property owners. Compaction is the process of making a soil denser through the application of dynamic impact to the soil mass. Specific minimum requirements are found within the current city construction specifications (standard specifications for road construction). Concrete masonry units (CMUs) are preformed concrete blocks typically used to construct retaining walls, yard walls, or building walls. They typically are available at most building supply and home improvement stores. Control measures (CMs) are preferred defensive mechanisms designed to reduce soil erosion from surface storm water. (See Stormwater Pollution Prevention Plan (SWPPP). Decorative retaining wall (segmented retaining wall). See garden retaining walls. Engineer (professional) is a person licensed by the New Mexico State Board of Licensure who is legally allowed to represent himself to the public as an engineer and is allowed to perform engineering design or construction of private and public works. Engineering site review is a surficial review of a site to determine its preliminary engineering capability based on exposed indicators that include historical site stability and past development(s). This investigation is performed under the direction of an engineer. Erosion control. See Stormwater Pollution Prevention Plan (SWPPP). Expansion joint is a designed break within a concrete or masonry structure to allow movement from both shrinkage (concrete curing) and thermal expansion/shrinkage. Expansive soils are soils that contain a high concentration of clay-sized particles that, when wetted, will expand in size and lose strength, or, when dried, will shrink and form a hard cemented layer. These soils are typically restrictive to the water passage. Fence is any artificially constructed access barrier consisting of posts, wire, wood, steel, cable or similar material to enclose or screen areas of land. Included within this definition are prefabricated fence panels (wood, plastic, or metal) that are typically sold at building supply stores. Garden walls (segmented walls) are walls constructed but not limited to using commercially available stacked concrete blocks to form its face. Typically, such walls are used to support raised planting beds for landscaping purposes. See LCMC, chapter 38, article VI, section 38-60 for additional wall information. Geotechnical soils investigation is an engineering investigation of the subsurface soils at a specific location to establish their unique engineering design properties. Investigations are documented with all findings, location(s), investigation equipment listing, with field crew names, and responsible engineer included. Geotechnical soils report is a written summary report containing all information obtained from a geotechnical soils investigation, a discussion of the findings and their evaluation(s), and a summary of specific engineering design recommendations, parameters, or designs. This document is signed and sealed by an engineer. Good engineering is the correct application of the current scientific principles to the evaluation, design, and construction of structural engineering projects. All projects must meet the minimum standards as adopted by the city. All designs are based on health, safety, convenience, and general welfare of the public. Ground water is free water/moisture located beneath the ground surface in soil pore spaces and rock fractures. Typically, it represents seepage from the ground surface or adjacent water sources. International Building Code (IBC) is the model building code developed by the International Code Council (ICC). This code has been adopted by the city for construction within the city exempting one- and two-family dwellings. International Residential Code (IRC) a comprehensive, stand-alone residential code which contains minimum regulations for one- and two-family dwellings and townhouses up to three stories. It brings together all building, plumbing, mechanical, fuel gas, energy and electrical provisions for one- and two-family residences. Landscape architect is an individual registered under the Landscape Architects Practice Act to practice landscape architecture in the state. Nothing contained in this definition shall be construed as authorizing a landscape architect to engage in the practice of architecture, engineering, or land surveying as defined by New Mexico Administrative Code, Title 16, Chapter 44, Landscape Architects. Mechanically stabilized earth (MSE) retaining walls are a style of retaining walls that appear similar to garden walls but are typically internally reinforced by geotextile/geogrid layers extending into their retained backfills from their block facings. These walls are designed by engineers. No disturbance zone (Figure A) is part of the designed foundation zone downslope of a retaining wall foundation. This zone develops the passive resistance to prevent the horizontal forces from the retained fill from moving the wall. Typically, this zone is a minimum width equivalent to the depth of the retained soil. [image omitted; see the official code] NPDES is the Federal National Pollutant Discharge Elimination System. This national law is the basis for the city Stormwater Management Plan (SWMP). Open landscape walls (segmented walls). See garden walls. Passive zone is the zone located immediately downslope of a retaining wall foundation that is specifically designed to prevent the wall from sliding from the pressure of the retained soil (see no disturbance zone.) Poorly drained soil is a soil gradation that contains a high percentage of silt and clay-sized particles that act to restrict water passage. Practice of engineering is any creative or engineering work that requires engineering education, training, and experience in the application of special knowledge of the mathematical, physical and engineering sciences to such creative work as consultation, investigation, forensic investigation, evaluation, planning and design of engineering works and systems, expert technical testimony, engineering studies and the review of construction for the purpose of assuring substantial compliance with drawings and specifications; any of which embrace such creative work, either public or private, in connection with utilities, structures, buildings, machines, equipment, processes, work systems, projects and industrial or consumer products or equipment of a mechanical, electrical, hydraulic, chemical, pneumatic, environmental or thermal nature, insofar as they involve safeguarding life, health, or property, including such other professional services as may be necessary to the planning, progress, and completion of any engineering work. Presumptive soil bearing capacity is a general soil bearing capacity value based only on the soil classification. City adopted presumptive soil bearing values shall be used if no site specific soil properties have been developed from a site investigation (see table for city design values in section 32-138, fences, walls, retaining walls, and slope protection). Alternate soil bearing capacity values may be used for design if based on a site-specific geotechnical investigation and laboratory soil testing. Private-to-private yard wall construction is the construction of a yard wall or garden wall on private land that does not have any impact on public lands or utilities. Retained fill depth (grade differential) is the fill depth retained by a retaining wall as measured by the soil surface elevation difference immediately adjacent to both sides of the wall. Retaining wall is a designed wall constructed of but not limited to brick, block, rock, concrete, MSE, or reinforced concrete, to retain over 24 inches of soil or surcharge. Retaining walls must be designed to resist the sum of all specific forces with a predetermined safety factor. Retaining wall system is a combination of retaining walls and slope protection designed and constructed to retain and protect a single large slope. Review for building permit application is the city's review of proposed development plans, documents, and specifications to insure compliance with all local, state, and federal applicable codes, standards, and ordinances. This review does not approve professional engineering design(s) but ensures only that reasonable engineering standards-of-practice have been employed in the design process. Rock wall (rubble stone) is a wall construction style composed of roughly fractured stones laid without regularity of coursing and bonded with cement grout forming consistent joints and high internal strength. Such construction can be used for either yard or retaining walls. Safety factor is a reasonable engineering design factor increasing a force or load to cover unknown factors/forces that may impact it. Typically such factors are in the range of 1.5—2.0 (min.) for retaining walls and may extend much higher for other specific engineered designs. Setback is the right-angle distance from an adjacent structure to a point on a property line. For more information see LCMC, chapter 38, article VI, section 38-62 and article VII, sections 38-70 through 38-73. Slope protection is a surface added to a slope to provide erosion protection. Typically it is composed of loose or cemented rock on slopes that are below their angle of internal friction, or part of a retaining wall system for slopes above their retained soil angle of internal friction. Specification is an explicit set of requirements to be satisfied by a material, product, or service. Stone masonry is the profession and skill used in building rock walls. Stone masonry, when properly designed, utilizes carefully fitted stones in a matrix of cement mortar to form a strong, durable, and stable structure. Stormwater Pollution Prevention Plan (SWPPP) is an engineered plan to combat potential pollutant sources at a construction site by presenting appropriate measures to prevent or control the pollution of stormwater runoff. It is based on the National Pollutant Discharge Elimination System (NPDES) laws and regulations. Minimum compliance to the SWPPP plan will identify and place best management practices (BMPs) and CMs that are locally available and have been proven successful at specific locations within/around the construction site. Structural fill is a fill designed by a professional engineer to have high strength that can support a structure without settlement or displacement. Such fills consist of soils that are both layer placed and compacted to high compaction levels. Typically, this construction is inspected and tested to ensure that the designed minimum compaction levels are achieved. Wall is an artificially constructed barrier of solid material such as brick, block, rock, concrete (or reinforced concrete), used to enclose or screen an area. Wall foundation zone (Figure B) is the zone that supplies the structural support for a wall and may include resistance to its lateral movement. This is the zone immediately below the foundation and includes the prepared subgrade it rests on. Wall height (cumulative) is the physical height of a wall measured vertically from the top of lowest adjacent finished grade to the top of the wall structure. [image omitted; see the official code] Wall height (retaining) is the difference of finished grade from opposite sides of the wall. Wall height (yard) is the physical height of a wall measured vertically from the top of highest adjacent finished grade to the top of the wall structure. Well-drained soil is a mixture of sand and rock with only minor amounts of silt and no clay component. Word terminology. Whenever construction permit documents contain the words "adopted," "reasonable," "suitable," "acceptable," "properly," "satisfactory," or words like "effect" and "import", unless otherwise specified herein, shall mean adopted, reasonable, suitable, acceptable, proper, or satisfactory in the judgment of the city and its engineer or designee. This acceptance refers only to the compliance with existing city codes and specifications and does not infer the acceptance of the responsibility for the accompanying design or construction. Yard wall is a wall constructed of, but not limited to, brick, block, rock, concrete or reinforced concrete, erected to enclose or screen yard areas. A yard wall may retain a grade differential of up to 24 inches and may be located on a property line with ownership shared between adjacent property owners. However, at the discretion of the chief development engineer or designee this grade differential may be extended up to 30" based on proposed design, loading and soil conditions. The decision of the chief development engineer or designee shall be final.
(Ord. No. 2804, §§ I, II(Exh. A), 2-6-17)
Ask a question about Las Cruces law
Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.
