Sec. 32-140. - Geotechnical soils investigation.
A geotechnical soils investigation shall explore and identify the type and structure of the subsurface soils at a specific site. A. Specific tests and activities shall be conducted to identify at a minimum: 1. Soil type, color, moisture-content, gradation, and index properties. 2. Changes in soil type with depth. 3. Soil strength tests at specific depths including zones of weakness. 4. Ground water table (GWT), its elevation, and the sampling date if encountered in the exploration. 5. Actual bottom-of-hole (BOH) elevation based on topographic site map to locate various soil strata and bearing capacity. B. Sampling: All laboratory testing shall come from undisturbed soil samples. C. Equipment information: 1. Describe the field exploration company, equipment, sampler size, operator and who logged hole. 2. Document weather, site, exploration hole location on site map, hole number, and the top-of-hole elevation/location. 3. Log all information onto field soil boring log sheets including field testing/sampling and its depth, the site, sign field log sheet. D. Ponds: Site investigation subsurface exploration depth below the designed bottom-of-pond (BOP) elevation with percolation tests to define the infiltration zone shall be: 1. Yard ponds. Exploration at least five feet (min.) below the designed bottom-of-pond (BOP) elevation for at least 20 percent of ponds in a development. Exploration points shall be equally spaced across proposed pond locations. 2. Community ponds. One exploratory hole at least ten feet below BOP (min.) for each pond. 3. City ponds. One exploratory hole at least 20 feet below BOP (min.) for each pond. 4. Soil samples shall be undisturbed samples for laboratory classification and permeability testing. Other parameters may be required to support specific pond requirements. They may include, but are not limited to, the following: a. Additional permeability tests at specific depths. This testing may be required for impoundments that are designed to permeate water into GWT during a specific time period. b. Installation of subsurface instrumentation required for engineering design or monitoring.
(Ord. No. 2804, §§ I, II(Exh. A), 2-6-17)
Ask a question about Las Cruces law
Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.