§ 32-144 — Walls
Municipal Code of the City of Las Cruces, New Mexico (Supp. No. 34: codified through Ordinance No. 3114, adopted June 1, 2026) · Las Cruces Development Code § 32-144
Corpus is an independent public-information project, not the official City of Las Cruces website. Stable reference: corpuslaw.us/code/743993a9-a03b-495d-a047-edee9114c939
Sec. 32-144. - Walls.
A. General design requirements: 1. Construction plans for proposed walls shall show property address, property lines, adjacent structures, surveyed location with setbacks, and setbacks in sufficient details to complete the construction. Construction plan details shall include surface drainage and surcharge load designations. Access portals through any wall shall be fully designed to insure retention of backfill. 2. The permittee is responsible for the location of all property lines affected by a proposed wall and shall be responsible for the location of footings and walls with respect to those boundaries. 3. Walls shall be set on stable soil. Areas identified by the city as having a history of instability shall be either stabilized as part of the wall design or the wall setback onto an adjacent stable site. Specific site investigation and design may be required. Figure C shows the differences in the three wall types. [image omitted; see the official code] 4. No items shall be attached to any wall unless included in the initial wall design. The design of additional attachments shall be signed and sealed by an engineer. 5. Reinforcing bars placed within all concrete structures shall be placed on chairs or tied prior to the placing of the concrete. Stabbing dowels into wet concrete is not allowed (see ACI 318). 6. Rock walls shall be constructed with no voids in their structure and contain large interlocking stones which overlap both horizontally and vertically. Material other than concrete mortar and rock is not allowed within a rock wall unless approved by the design engineer. The presence of unapproved material within a rock wall will be the basis for rejection of construction. 7. Minimum construction temperature. For both concrete and mortar construction is 40°F and rising for both air and ground temperatures for concrete sections under 12 inches thick. No ice shall be present within the materials (mixing sand and water) to be added to fresh mortar/concrete. Temperature projections for the four days immediately following placement shall remain above 40°F or the construction shall be covered and heated to 55°F (min.) for the same period (see ACI 306R-88). 8. Maximum concrete temperature. For concrete placement, the maximum maintained allowable temperature is 90°F. If concrete is to be cooled by the addition of ice, after-placement-slump tests are to be taken to ensure that the water/cement ratio remains within design tolerances. If outside the allowed water content, the specific truck of concrete is rejected and all its concrete is to be removed from the work site. 9. Once mixed, concrete and cement mortar shall not be retempered by the addition of water or sand and shall only be placed while in a workable condition. Once the mortar has started to "set," it shall not be used and must be removed from the construction site by the contractor. 10. Cement shall not be stockpiled on the work site. Sand may be stockpiled on the work site provided it is protected from moisture and adjacent contamination. All loose material shall be stored away from streets and storm drains. Approved silt fencing, or filtration medium, to prevent siltation, shall be used to protect all on-site storm drain systems. 11. Only walls designed and constructed by the city for public projects shall be constructed on city property per their approved construction plans. No private wall shall be constructed within city right-of-way. 12. Common yard wall. Private-to-private yard wall six feet or under in height from the finished grade and is not a retaining wall will require no building permit or public inspection but shall require a wall and fence zoning certificate. The integrity of the construction is the sole responsibility of the property owner. Private to public yard wall. Walls that abut public property or whose collapse zones are within public property shall be subject to building permit and public inspection. (See also section 32-1441, yard walls.) 13. Any wall that will help restrain wind or water erosion within a lot or area may be constructed during the project's initial construction phase. This designation shall be identified as part of the site design by the engineer and verified by the city prior to the construction permit issuance. B. Concrete: 1. All concrete shall have a minimum tested compressive strength of 3,000 psi after a 28-day cure for wall construction. All concrete mix designs shall be forwarded to the city for approval prior to start of construction (mix design documentation is typically available from concrete plant mix supplier). 2. All concrete quantities over one cubic yard shall be plant mixed with a minimum strength of 3,000 psi after a 28-day cure. Concrete quantities less than one cubic yard may be site mixed but shall have a minimum compressive strength of 3,000 psi after a 28-day cure. 3. Portland cement shall conform to ASTM C150/C150M and shall be Type I or Type II. C. Mortar: 1. Mortar for all retaining walls shall have a minimum compressive strength of 1,800 psi. Yard walls shall comply with ASTM C270-12. Mortar cubes shall be cured and tested in accordance with AASHTO T 106. 2. Required proportioning shall be determined from the mix design by a testing laboratory and signed by an engineer. Mortar for rock wall, retaining wall, and slope protection shall be Type S prepared per ASTM C270 and tested in accordance with ASTM C780, using procedure A1 or A3. All mix design certification shall be forwarded to the city for approval prior to start of construction. 3. Mortar mixing may be by hand or a rotating paddle-mixing machine. Mortar shall be sampled in accordance with ASTM C172. 4. Mortar shall only be placed while in a "workable" condition with no signs of it starting to "set". If a rock is moved once the mortar has started to set, the mortar shall be removed and replaced with fresh mortar before the rock is replaced. 5. It is intended that the mortar width between the rocks should be uniform in appearance. The minimum joint width should be no less than one-half inch wide. Rock that comes into contact with an adjacent rock (i.e. no joint) will not be allowed. All mortar joints shall be filled to within one-quarter inch of the wall face with a smooth finish. For nonstandard mortar joint architecture, alternative designs shall be submitted for review and approval by the city. 6. Portland cement for mortar shall conform to ASTM C150M and shall be Type I or Type II. 7. Sand for site-mixed mortar shall be commercially washed and supplied. 8. Sand shall only be stored on-site when separated from underlying ground surface and protected from all adjacent contamination. 9. Mortar joints on rock walls may have small pieces of rock (shards) placed into their exposed surfaces for appearance provided that the following is achieved: a. After the mortar has been placed to within one-quarter inch of the exterior wall surface, the rock shards may be installed. b. All shards shall be both clean and moist when inserted into the grout surface. D. Rock: 1. Rock for wall construction shall be placed with all surfaces clean and damp for good mortar adhesion. 2. Rocks for wall construction shall be of size and shape, and laid in a manner, that they "overlap" both horizontally and vertically within the wall. 3. Rocks grouted onto the outer face(s) of a wall in a "veneer" fashion, shall include a "tie" structure extending into the wall. Such "tie" structure shall be designed by an engineer. 4. All rock for wall construction shall be of a quality such that it will not flake or disintegrate. E. Wall foundation: 1. All wall footings shall bear on a compacted cohesionless (sand/crushed gravel) subgrade soil a minimum of eight inches thick and not on a cohesive (silt, clay, or caliche) soil. All foundation soils shall be compacted to 95 percent of ASTM D1557-12 or AASHTO T 180 test standards, at a moisture content of plus or minus two percent of optimum. 2. All footings (except garden wall) shall be constructed of concrete with vertical faces on all four lateral sides. Locations where the soil will not hold a vertical face the foundation faces will be formed. 3. Unless differing engineering recommendations with calculations have been developed, the following shall apply: a. Footing thickness shall be 12 inches of concrete (min.). b. Minimum footing reinforcement is two #4 deformed bars (continuous) with 14 fourteen inches (min.) lateral spacing and #4 cross-bars at 24 inches spacing (max.). Footing continuous reinforcing shall comply with ACI 318, with a minimum steel ratio of 0.0014. c. Concrete covering over all reinforcing bars and their ends shall be three inches thick (min.). All reinforcing bars shall be supported by chairs to insure three inches of concrete cover. d. Soil cover over the top of wall footing shall be six inches (min.). e. First course of rock above the footing shall have an average diameter between eight inches and 16 inches with a six-inch (min.) embedment into the foundation concrete. F. Final cleanup: 1. All exposed wall surfaces, and adjacent ground surfaces, shall be cleaned of splattered mortar left from construction. All debris and removed mortar shall be removed from the construction site by contractor. 2. All adjacent disturbed soil shall be constructed to designed shape and contour per final design. All adjacent soil surface shall be planted for erosion prevention or designed landscaping. G. No disturbance zone (see Figure A): 1. Construction/disturbance plans within a no disturbance zone shall be designed by an engineer and approved by the city. 2. Design documentation shall include: a. Geotechnical soils report signed and sealed by and engineer. b. Project specific construction drawings and supporting design calculations. c. Building permit application shall include both a and b. 3. Ground surfaces down-slope of the no-disturbance zone shall be no steeper than 3:1 (H:V). 4. The no-disturbance zone shall not extend onto adjacent property except within a permanent retaining wall easement for both slope stability and maintenance. H. Garden walls may be constructed without an engineered design or a city building permit provided they meet the following criteria (1—4): 1. Garden walls shall be constructed using the manufacturer's design and construction specifications and have a grade differential of not more than 24 inches. 2. Any garden wall retaining over 24 inches high shall be considered to be a retaining wall and shall require a review by the city for adequacy, zoning, and ordinance compliance prior to issuance of a construction permit. 3. Garden walls may be constructed along property lines if within their height restrictions, have a level backfill, and must totally remain on the wall owner's property. 4. Private garden walls shall not be located on city property. 5. Garden walls 48 inches high and under may be designed by a landscape architect registered in the state. Such walls shall have no backfill reinforcement, have a level backfill, and no additional surcharge. Design drawings shall be signed and sealed by a state registered landscape architect. 6. Garden walls over 48 inches high with reinforced backfill, or backfill surcharge above level shall be signed and sealed by an engineer. I. Yard walls—Reinforced concrete, masonry, or rock/mortar (Figures D and E under section 32-145, retaining wall design standards). Yard walls may be constructed without an engineered design provided they meet all of the following design criteria: 1. Yard wall may have a maximum grade differential of 24 inches between its front and back. Deviations to this provision may be considered on a case by case basis by the chief development engineer. 2. Yard wall foundation zone shall have a history of stability or be constructed as a structural fill. 3. Yard walls separating individual lots may be constructed as part of the individual lot development(s). 4. Yard wall height shall be no more than eight feet high (max.) as measured from the top of the lowest adjacent grade to the top-of-wall. 5. Yard wall footing width shall have the following minimum widths: • Reinforced concrete and reinforced masonry wall: 20 twenty inches (min.). • Mortared rock wall: 20 inches (min.). 6. Yard wall expansion joints are required for both concrete masonry units (CMUs) and reinforced concrete walls and shall be spaced 16 feet (max.) along each wall segment. These joints shall extend from the foundation to the top-of-the-wall. 7. Yard wall thickness (min.): • Reinforced masonry: six inches (min.). • Mortared rock: 16 inches (min.). • Reinforced concrete: six inches (min.). 8. Yard wall reinforcement (min.): • Reinforced concrete: #4 rebar vertically and horizontally at 18 inches on center (max.) with #4 footing dowel at 36 inches. • Reinforced masonry: #4 rebar vertically at 24 inches (max.) with #4 footing dowel at 48 inches and #4 rebar horizontally in an eight- inch (max.) bond beams at the top of the wall and at 48 inches (max.). • Mortared rock: Mortared rock walls shall not contain steel reinforcement except in its concrete footing. 9. Any yard wall that does not meet the above specifications shall be designed by an engineer.
(Ord. No. 2804, §§ I, II(Exh. A), 2-6-17)
Ask a question about Las Cruces law
Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.
