Sec. 32-143. - Slope protection.
The following applies to all slope protection applications: A. All slope protection designs steeper than 3:1 shall be designed by a license professional engineer and reviewed by the city prior to issuance of a construction permit. B. Mortar for rock slope protection shall be Type M and shall have a minimum compressive strength of 2,500 psi at 28 days as determined by the AASHTO T 106 test. A mix design certification for the mortar mixture shall be forwarded to the city for compliance review and approval prior to use. C. Rock and mortar slope protection shall be both internally and externally drained to expel collected water to designed collection point(s). D. Internal drainage of slope protection shall: 1. Use two-inch diameter (min.) high-density polyethylene (HDPE) pipes (or better) extending through the slope protection. 2. Drainage pipe inlet ends shall have a single layer of geotextile gravel drain zone (drainage) over them. 3. Horizontal spacing of the drainage pipes shall be 20 feet (nominal). 4. Additional rows of drainage pipes shall be spaced every ten feet of slope distance. 5. Drainage pipe locations shall be staggered from adjacent row locations. 6. Pipes shall be sloped to drain onto slope protection surface. 7. Drainage pipes shall have a secured geotextile (drainage) covering over their inlet ends if draining a sand retained back-fill. E. The downslope edge of slope protection shall include a stable foundation structure to prevent movement. F. The downslope edge shall be graded to drain collected water to designated areas as designed. G. The unprotected soil adjacent to slope protection shall not be steeper than four to one (4H:1V) unless otherwise recommended by a geotechnical soils report and designed by an engineer. Adjacent slopes shall drain surface water away from the slope protection. H. Prior to placing slope protection, the fill slopes shall be constructed as a structural fill including both layer placement and compaction. Compaction testing is defined in the City of Las Cruces Standard Specifications for Road Construction, latest Edition. I. Cut slope construction (undisturbed soil) shall have its exposed surface compacted in accordance with the City of Las Cruces Standard Specifications for Road Construction, latest Edition. J. Rock and mortar slope protection shall have a six-inch thick mortar bed (min.) with rocks embedded three to four inches into the mortar. The joints between rocks shall be tightly packed with mortar. The mortar shall extend to within one-quarter inch of the rock surface. The minimum joint width should be no less than one-half inch wide. Rock that comes into contact with an adjacent rock (i.e. no joint) will not be allowed. Rock and mortar slope protection shall be constructed with no voids in their structure. Material design elements other than concrete, mortar and rock is not allowed within a rock and mortar slope protection system unless approved by the design engineer. The presence of unapproved material will be the basis for rejection of construction. Alternative designs for any slope protection will be considered by the community development department. K. Rock used in slope protection construction shall meet the size as specified in the latest Edition of the New Mexico Department of Transportation (NMDOT) Standard Specifications for Highway and Bridge Construction. All rock for slope protection shall be of a quality such that it will not flake or disintegrate. L. Slope protection using planted vegetation is encouraged. Its design shall be in compliance with the city landscape design standards and shall include an adequate watering system, plant maintenance plan, and meet the following specifications: 1. Plants specified shall be suitable for the Chihuahuan Desert climate. Native plants are preferred but other suitable plants will be considered for approval by the city landscape architect. 2. All seed planting shall be covered with a securing blanket to protect seeds to full germination. 3. Planting and irrigation plans must be stamped by a landscape architect licensed to practice in the state. 4. A varied planting is more effective than a monoculture on a slope, and therefore, is desired by the city. 5. Use of plastic sheeting under a mulch layer is not allowed. 6. Organic mulch (i.e., straw mats, tacked clean straw, bark-mulch, or similar) are recommended for use with newly planted vegetation. 7. Slopes steeper than 4:1 shall not be used for planting slope protection. 8. United States Department of Agriculture (USDA) Natural Resources Conservation Service (NRCS) practice standards shall be met for slope protection planting as presented in the following guidelines: a. Reference NRCS Conservation Practice Standard, Conservation Cover, Code 327. b. Reference NRCS Conservation Practice Standard, Critical Area Planting, Code 342. c. Reference NRCS Conservation Practice Standard, Mulching, Code 484. d. Reference NRCS Conservation Practice Standard, Runoff Management System, Code 570.
(Ord. No. 2804, §§ I, II(Exh. A), 2-6-17)
Ask a question about Las Cruces law
Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.