§ 32-138 — Fences, walls, retaining walls, and slope protection
Municipal Code of the City of Las Cruces, New Mexico (Supp. No. 34: codified through Ordinance No. 3114, adopted June 1, 2026) · Las Cruces Development Code § 32-138
Corpus is an independent public-information project, not the official City of Las Cruces website. Stable reference: corpuslaw.us/code/429adf78-b5c1-4d68-ae9c-5de05cae8b1d
Sec. 32-138. - Fences, walls, retaining walls, and slope protection.
The following shall be applied to all fences, walls, retaining walls, and slope protection designs and construction: A. Construction permit applications, when applicable, shall include all structural calculations, investigative reports, and design documentation. B. All fences, walls, retaining walls, and slope protection within the city shall be designed and constructed per LCMC, chapter 32 and in accordance with the latest city-adopted edition of the IBC for both private and public construction. The zoning code height restriction that shall be applied is stated in LCMC, chapter 38, article VI, section 38-60. C. The exposed face(s) of a fence, yard wall, or a yard/retaining wall combination shall be designed to resist 90 mph winds acting perpendicularly against front and back wall exposures. Use the design criteria specified in ASCE 7-10. D. The following design values shall be used when no geotechnical site-specific investigation and subsequent laboratory test values have been developed: City of Las Cruces Design Values Ø | 28° | a Soil Angle of Internal Friction (max.) γs | 120 PCF | a Compacted (dry) Soil Density (min.) γ'w | 43.3 PCF | c Active Equivalent Fluid Pressure (min.) K | (Only Soil Test Value) | b Soil Permeability Coefficient P use | 2,000 PSF | a Useable foundation bearing capacity (IBC max) F y | 60 KSI | Rebar, yield strength (min.) S 28 | 3,000 PSI | Concrete compressive strength, 28 days (min.) S 28 | Based on ASTM C270 design for (yard walls only) | Mortar use type S cement, designed per ASTM C270, and field tested per ASTM C780 procedure A1 & A3 S 28 | 1,800 PSI (retaining walls only) | Mortar use type S cement, compressive strength (min.) γc | 150 PCF | Density of concrete (min.) γRW | 135 PCF | Density of rock masonry wall (min.) ∫ | 0.25 | Coefficient of friction for soil/concrete (IBC) (max.) a Site specific soil properties gained from a geotechnical investigation and subsequent soil laboratory testing shall be used when available. b Published soil permeability data typically relate poorly to local stratigraphy and soil structure, therefore only site-specific field/laboratory permeability tests shall be used. c Based on 120 PCF and ø = 28° E. Proposed excavation of existing ground surface immediately downslope of a structure (wall/building), known as the "no disturbance zone," shall not be undertaken unless a specific engineering analysis and design determines that the structure will remain stable during and after the excavation. Such design documents shall be signed and sealed by an engineer and meet all requirements as listed in OSHA Trenching and Excavation Standards, 29 CFR, Part 1926.650. If this zone extends onto adjacent property, it shall be within a maintenance easement signed by the adjacent property owner of record. F. It shall be the property developer/owner's responsibility to ensure that their development does not extend onto, or impact, adjacent lots, properties, or developments. An engineer shall provide full design documentation with signature and seal for all development plans. G. All development shall prevent drainage impacts on adjacent slopes and structures. H. Walls and fences in a special flood hazard area (SFHA). All walls and fences located in a SFHA as determined by the Federal Emergency Management Agency (FEMA) shall obtain a building permit and meet requirements of city flood plain administration. I. Any retaining wall foundation or its "no disturbance zone," shall not extend into a special flood hazard area (SFHA), floodplain, or on-lot ponds without a geotechnical engineering design to ensure its continued foundation stability under flood saturation or erosion. All such designs shall be based on an established base flood elevation from a 100-year event (one percent chance of occurrence). Documentation shall include a hydrologic evaluation to confirm full compliance with CFR, Title 44 and LCMC, chapter 34. These engineered designs must include all documentation with signature and seal. J. Reserved. K. The minimum upslope setback for any wall from the top edge(s) of a soil bank/slope is typically two times the wall height as measured from the top of the stable portion of the bank to the closest edge of the wall foundation. This value may be modified by an engineer based on a geotechnical soils investigation and associated design. Additional setback distance adjustments may be added by the city's engineering staff or the community development department if the stability of a soil slope(s) or the soil bearing capacity could become compromised from flooding, stability, or if it has a history of instability.
(Ord. No. 2804, §§ I, II(Exh. A), 2-6-17)
Ask a question about Las Cruces law
Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.