For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7.0.3 — GENERAL RULES OF APPLICABILITY

Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Zoning Code, art. 7, § 7.0.3

Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/4a22006a-7a37-4f60-a2f1-ffb4bafe6a63

7.0.3. - GENERAL RULES OF APPLICABILITY

A. Applicability The following general rules of applicability apply to all Form Districts, except the South Waterfront District. ![Figure: AppB-7-0-3-B.png](https://figures.74-208-44-221.nip.io/knoxville/497059/0103cffe6153320173c4b46f8de59b45c5d0340395a2df7b342413f8bf340755-AppB-7-0-3-B.png) B. Lot Width Lot width is the distance between the 2 side lot lines measured at the primary street property line along a straight line or along the chord of the property line on a curvilinear lot. C. Building Setbacks 1. There are 4 types of building setbacks—primary street, side street, side interior and rear. ![Figure: AppB-7-0-3-C.png](https://figures.74-208-44-221.nip.io/knoxville/497059/85cf148853f74195836854c5cf90a9536332dfe88c3bd67baa55230488fe22a3-AppB-7-0-3-C.png) 2. Primary and side street setbacks are measured from the edge of the right-of-way. 3. Primary and side streets are designated in each specific Form District. 4. Side interior setbacks are measured from the side property line. 5. Rear setbacks are measured from the rear property line or the edge of the right-of-way where there is an alley. 6. When the side interior or rear setback is 0 or 5 feet, the building or structure must be placed on the side or rear property line or be placed a minimum of 5 feet from the side or rear property line. 7. For developments on corner lots, the building must be located as to provide for adequate sight distance as approved by the City of Knoxville, Department of Engineering. D. Build-To Zone (BTZ) 1. The build-to zone is the area on the lot where a certain percentage of the front building façade must be located, measured as a minimum and maximum setback range from the edge of the right-of-way. 2. The required percentage specifies the amount of the front building façade that must be located in the build-to zone, measured based on the width of the building divided by the width of the lot. ![Figure: AppB-7-0-3-D1.png](https://figures.74-208-44-221.nip.io/knoxville/497059/ed0773e791ce2c911044a4787243763cc8ffadda9ecef309ad66269b03052ddd-AppB-7-0-3-D1.png) 3. On a corner lot, a building façade must be placed within the build-to zone for the first 30 feet along the street extending from the block corner, measured from the intersection of the 2 right-of-way lines. ![Figure: AppB-7-0-3-D2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/5f5d582dba4bf5eacee86e6430a817913ecf785b45716a3aa24a0c8ef5ccecdc-AppB-7-0-3-D2.png) 4. Outdoor seating and dining areas may qualify as building façade for the purpose of meeting the build-to requirement provided that the following standards are met: a. The front building façade is located no more than 10 feet behind the maximum street setback; b. The outdoor seating and dining area is no more than 2/3 the width of the building; c. The outdoor seating and dining area is no more than 16 feet deep; and d. The seating area is separated from the sidewalk by a wall or fence no higher than 4 feet above the sidewalk. ![Figure: AppB-7-0-3-D3.png](https://figures.74-208-44-221.nip.io/knoxville/497059/71ed397af2affea799019f88422394aeaf152551fad0de017694007637f10d5d-AppB-7-0-3-D3.png) E. Setback Encroachments All buildings and structures must be located at or behind required setbacks, except as listed below. Unless specifically stated no building or structure can extend into a required easement or public right-of-way. 1. Building Features a. Porches, stoops, balconies, galleries and awnings/canopies can extend into a required setback under Sec. 7.2.4. b. Chimneys or flues may extend up to 4 feet, provided that such extension is at least 2 feet from the vertical plane of any lot line. c. Building eaves, roof overhangs and light shelves may extend up to 4 feet, provided that such extension is at least 2 feet from the vertical plane of any lot line. d. Bay windows, entrances and similar features that are less than 10 feet wide may extend up to 4 feet, provided that such extension is at least 2 feet from the vertical plane of any lot line. e. Unenclosed fire escapes or stairways may extend up to 4 feet into a required side or rear setback, provided that such extension is at least 5 feet from the vertical plane of any lot line. f. Unenclosed patios, decks or terraces may extend up to 4 feet into a required side setback, or up to 8 feet into a required rear setback, provided that such extension is at least 5 feet from the vertical plane of any lot line. g. Outdoor seating and dining areas may extend into a primary or side street setback. h. Cornices, belt courses, sills, buttresses, or other similar architectural features may project up to 1½ feet. i. Handicap ramps may encroach to the extent necessary to perform their proper function. j. Building features below and covered by the ground may encroach into any required setback. k. Habitable space or structured parking may encroach over an existing or proposed alley with approval of an encroachment agreement by the City, provided that the alley remains public and a minimum clear height of 16 feet is maintained for vehicles. ![Figure: AppB-7-0-3-E.png](https://figures.74-208-44-221.nip.io/knoxville/497059/fbec3ef425c4a082608843f16d976699142b83321083e04d00064830aa7ced94-AppB-7-0-3-E.png) 2. Mechanical Equipment and Utility Lines a. Mechanical equipment associated with residential uses, such as HVAC units and security lighting, may encroach into a required rear or side setback, provided that such extension is at least 3 feet from the vertical plane of any lot line. b. Solar panels, wind turbines and rainwater collection or harvesting systems less than 10 feet in height may encroach into a required rear setback, provided that such extension is at least 5 feet from the vertical plane of any lot line. c. Minor structures accessory to utilities (such as hydrants, manholes, and transformers and other cabinet structures) may encroach into a required rear or side setback d. Mechanical equipment and utility lines below and covered by the ground may encroach into any required setback. F. Parking Setbacks 1. There are 4 types of parking setbacks—primary street, side street, side interior and rear. 2. On-site surface and structured parking must be located behind the parking setback line. This requirement is not intended to restrict on-street parking. 3. Primary and side street parking setbacks are measured from the edge of the right-of-way. 4. Side interior setbacks are measured from the side property line. 5. Rear setbacks are measured from the rear property line or the edge of the right-of-way if there is an alley. 6. When the side interior or rear parking setback is 0 or 5 feet, parking spaces must be placed on the side or rear property line or be placed a minimum of 5 feet from the side or rear property line. G. Outdoor Amenity Space 1. Outdoor amenity space must be provided on the lot and must be available for use by the occupants of the development. 2. Outdoor amenity space may be met in a contiguous open area or in multiple open areas on the lot; however, to receive credit the area must be at least 10 feet in width and length. 3. Outdoor amenity space may be located at or above grade. 4. Outdoor amenity space provided at grade cannot be built, parked or driven upon, except for emergency access and permitted temporary events. 5. Outdoor amenity space provided above grade may be roofed but cannot be enclosed. ![Figure: AppB-7-0-3-G.png](https://figures.74-208-44-221.nip.io/knoxville/497059/ea1212fb54aa7dbb3277dfcf9ea14652d4be0cf501c51eba8a466941bcae9d34-AppB-7-0-3-G.png) H. Building Height 1. Building height is measured in both the number of stories and in feet. Building height is the vertical distance from average grade to the average height of the highest roof. For roofs with less than a 4 in 12 pitch, height is measured to the highest point of the roof. ![Figure: AppB-7-0-3-H1.png](https://figures.74-208-44-221.nip.io/knoxville/497059/4fec79fa2922e63e99da0349b55330f3585d4a8a4db48ca5891543bf8c3c1533-AppB-7-0-3-H1.png) 2. Average grade is determined by calculating the average of the highest and lowest elevation along natural or improved grade (whichever is more restrictive) along the front of the building parallel to the primary street setback line. ![Figure: AppB-7-0-3-H2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/6ed350e55524efd85a799387f8f1c3dfa7cbcea63237f6b89c9bd30e5ccae747-AppB-7-0-3-H2.png) 3. Where a lot slopes downward from the front property line, 1 story that is additional to the specified maximum number of stories may be built on the lower, rear portion of the lot. ![Figure: AppB-7-0-3-H3.png](https://figures.74-208-44-221.nip.io/knoxville/497059/31f8c0c8a0f50ee7c6ead085d9e7f1d4ab1403e560ac9a2f00313d2809c82598-AppB-7-0-3-H3.png) 4. An attic does not count as a story where 50% or more of the attic floor area has a clear height of less than 7½ feet; measured from the finished floor to the finished ceiling. ![Figure: AppB-7-0-3-H4.png](https://figures.74-208-44-221.nip.io/knoxville/497059/6bf9de2b779b8f4d596903d72b0e00258066ec6a9302575158558f05a0bb5f37-AppB-7-0-3-H4.png) 5. A basement with 50% or more of its perimeter wall area surrounded by natural grade is not considered a story. I. Height Encroachments Any height encroachment not specifically listed is expressly prohibited except where the Administrator determines that the encroachment is similar to a permitted encroachment listed below. 1. The maximum height limits do not apply to spires, belfries, cupolas, domes not intended for human occupancy; monuments, water tanks/towers or other similar structures which, by design or function, must exceed the established height limits. 2. The following accessory structures may exceed the established height limits, provided they do not exceed the maximum building height by more than 6 feet: a. Chimney, flue or vent stack; b. Deck, patio, shade structure; c. Flagpole; d. Garden, landscaping, green roof; e. Parapet wall; and f. Solar panels, wind turbines and rainwater collection or harvesting systems. 3. The following accessory structures may exceed the established height limits, provided they do not exceed the maximum building height by more than 10 feet, do not occupy more than 25% of the roof area, and are set back at least 10 feet from the street-side edge of the roof: a. Amateur communications tower; b. Cooling tower; c. Elevator penthouse or bulkhead; d. Greenhouse; e. Mechanical equipment; f. Skylights; and g. Elevator or stairway access to roof. 4. An accessory structure located on the roof must not be used for any purpose other than a use incidental to the principal use of the building. J. Story Height 1. Story height is measured from the top of the finished floor to the ceiling above. 2. Minimum ground story height applies to the first 20 feet of the building measured inward from the street facing façade. 3. At least 80% of each upper story must meet the minimum upper story height provisions. ![Figure: AppB-7-0-3-J.png](https://figures.74-208-44-221.nip.io/knoxville/497059/e74179054ebfa17020335d77bf24cdcbce6560e3950662c33648893d80786bce-AppB-7-0-3-J.png) K. Ground Floor Elevation 1. Ground floor elevation is measured from the highest point of the abutting sidewalk to the highest point of the finished ground floor. 2. Minimum ground floor elevation applies to the first 20 feet of the lot measured from the right-of-way line. ![Figure: AppB-7-0-3-K.png](https://figures.74-208-44-221.nip.io/knoxville/497059/d2a589fce1122a3adc5a881f417320b4cf44b3b6ec0c4ec6341872a03864f665-AppB-7-0-3-K.png) 3. On slopes greater than 6%, the ground floor elevation may not be located more than 3 feet above grade or 1 foot below grade on street-facing façades. L. Transparency 1. Transparency is the minimum percentage of windows and doors that must cover a ground or upper story façade. 2. The transparency requirement on ground story façades is measured between 2 and 10 feet above the adjacent sidewalk. 3. The transparency requirement on upper story façades is measured from the top of the finished floor to the top of the finished floor above. When there is no floor above, upper story transparency is measured from the top of the finished floor to the top of the wall plate. 4. Glass is considered transparent where it has a transparency higher than 80% and external reflectance of less than 15%. 5. Transparency applies to primary and side street-facing façades only. ![Figure: AppB-7-0-3-L.png](https://figures.74-208-44-221.nip.io/knoxville/497059/fe8751a74067bf24c84a59e1ffa11844d25ddf1aac8294287f5be66e82da88b8-AppB-7-0-3-L.png) M. Blank Wall Area 1. "Blank wall area" means a portion of the exterior façade of the building that does not include: windows or doors; columns, pilasters or other articulation greater than 12 inches in depth; or a substantial material change (paint color is not considered a substantial change). ![Figure: AppB-7-0-3-M.png](https://figures.74-208-44-221.nip.io/knoxville/497059/640e9df56ef70d81bb57e804c88778dd6cf40aedad6b0c56ea47bb7c9fb9b7bc-AppB-7-0-3-M.png) 2. Blank wall area applies in both a vertical and horizontal direction. 3. Blank wall area applies only to ground and upper story street-facing façades. N. Building Entrances 1. An entrance providing both ingress and egress, operable to residents at all times or to customers during normal business hours, is required to meet the street facing entrance requirements. Additional entrances are allowed. 2. The entrance separation requirements must be met for each development, but are not applicable to adjacent (existing) development. ![Figure: AppB-7-0-3-N.png](https://figures.74-208-44-221.nip.io/knoxville/497059/48d279c4e819ca194d06daf0b894d4c66df76b51a241b9c4eea2fec4a6483eb0-AppB-7-0-3-N.png) 3. An angled (clipped corner) entrance may be provided at any corner of a building along the street to meet the street entrance requirements, provided the applicable entrance spacing requirements can still be met. O. Building Materials 1. Applicability The requirements of this Section apply to all street-facing façades of a building. 2. Primary Materials Primary material changes must occur only at inside corners. The following materials are required for not less than 75% of the building wall surface area on each façade: a. Brick and tile masonry; b. Stone (or synthetic equivalent); c. Wood—clapboard or shingles; d. Glass curtain wall; e. Cementitious siding; and f. Stucco (cementitious finish). 3. Accent Materials The following materials may make up 25% of the building wall surface area on each façade: a. Pre-cast masonry (for trim and cornice elements only); b. External Insulation Finishing System—EIFS (for trim and cornice elements only); c. Gypsum Reinforced Fiber Concrete (GFRC—for trim elements only); d. Metal (for beams, lintels, trim elements and ornamentation only); e. Split-faced block (for piers, foundation walls and chimneys only); f. Wood—clapboard or shingles; g. Cementitious siding; and h. Glass block. 4. Alternate Materials Alternate building materials may be approved by the Administrator. New materials must be considered equivalent or better than the materials listed above, and regionally-available materials are preferred.

Ask a question about Knoxville law

Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.