For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7.1.8 — MARINA STANDARDS

Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Zoning Code, art. 7, § 7.1.8

Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/46bdc676-3a03-4b2e-9819-160d093b0cf7

7.1.8. - MARINA STANDARDS

![Figure: AppB-7-1-8.png](https://figures.74-208-44-221.nip.io/knoxville/497059/d1f0d8ec783a23111eb1b96ee0370e8885dd0764c7f198c60c53fd14a059f57f-AppB-7-1-8.png) A. Vision and Intent To establish minimum requirements for the siting, design, construction, and operation of marinas to serve the needs of boaters, while properly managing the State's natural resources, and protecting public health. B. Siting 1. Marina Types Permitted uses include marinas as accessories to mixed use development, for mooring boats and/or for fueling boats. 2. Marina Siting Satisfy TVA, USACE, and State of Tennessee requirements. Marina must minimize adverse effects on flow of water, commercial boat traffic and recreational rowing, minimize dredging and minimize accumulation of sediments. 3. Marina Size As a guide, the riverside width of marina shall not project past the TVA and USACE assessment line as shown on the regulating plan. Minimum clear distance of fairway aisle between finger float ends shall be minimum 1.5 times the length of the longest finger float but not less than 40'. Marina length may be no longer than the property it serves. 4. Marina Depth Minimum 6 feet of water at normal low pool, max no deeper than river channel. If excavation is required to accomplish the minimum depth, TVA, USACE, or the State of Tennessee may require sediment testing to determine environmental impact of any potential dredging. 5. Permitted Uses Marinas as accessories to mixed use development, for mooring boats and/or for fueling boats. 6. Non-Permitted Uses Dry boat maintenance, dry lifts, dry boat storage, residential boat houses, covered moorings, in-water maintenance such as pressure washing or hull scraping. C. Dimensions 1. Gangway Gangways shall have a minimum clear width of 3 feet and at least one gangway slope must meet ADA requirements. Gangways shall be aluminum with guardrails, handrails and kick plate. Gangways shall be hinged at one end and sliding at the other. Gangways shall be capable of disconnecting and stowing during flood events. 2. Top Landing Top landing shall have a minimum of 5 feet by 5 feet platform with guardrail and lockable gate. 3. Utilities All utilities servicing floats shall have a shut off and/or emergency disconnect adjacent to the top of the gangway. Potable water and fire suppression lines shall not be combined. 4. Main Floats Main floats shall be not less than 5 feet in unobstructed width. 5. Finger Floats Finger floats shall be not less than 3 feet unobstructed in width. In-River Marina Configuration #1 ![Figure: AppB-7-1-8C-1.png](https://figures.74-208-44-221.nip.io/knoxville/497059/15da790208f74ac1dd218522c84b5a157648f20ea1bf0de377e762bf5ecfa291-AppB-7-1-8C-1.png) In-River Marina Configuration #2 ![Figure: AppB-7-1-8C-2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/ad78a68e143a8d55c0d0b3661c6ce67a845b37811d3fe7b0c30c40efd27f0ea2-AppB-7-1-8C-2.png) In-Bank Marina Configuration ![Figure: AppB-7-1-8C-3.png](https://figures.74-208-44-221.nip.io/knoxville/497059/3bf04545be5c98b0facdb6d6d75aac1324b6381ce7e116fdfcae9b43e11c62d1-AppB-7-1-8C-3.png) D. General Standards 1. Structural Loads a. Debris Deflection Locate float systems and/or breakwater to deflect floating debris around marina. b. Flotation Materials Timber logs and wood flotation shall not be used. Concrete, steel, polyethylene, encapsulated foam, pontoon systems may be used and all floats used for fuel docks shall be concrete impervious to fuel spillage. c. Impact Loads Waterfront structures shall be designed for impact loads from vessels and floating debris up to a 1 in 100 year flood. d. Flotation and Anchoring Steel guide piles or hinged steel arms must enable marina to float up to 1:100 year flood elevations plus freeboard. Fixed Marinas are not permitted. 2. Environmental Considerations a. Sewage Management No sewer discharge to any waters. One fixed-point collection system at centrally located pumpout station to discharge to city sewer. b. Fuel Management If fuel facilities are proposed, only land based underground storage tank out of floodway is permitted. 3. On-Shore Components a. Off Street Parking Not required for marinas as an accessory to residential buildings. b. Loading Area Allow service vehicle access to top of gangway landing. c. Signs Signs other than for navigation and regulation are not permitted.

Ask a question about Knoxville law

Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.