§ 7.2.9 — SITE LIGHTING

Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Zoning Code, art. 7, § 7.2.9

Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/36c2e9b7-3ce7-45ab-9ac6-fc81a2b5dc8f

7.2.9. - SITE LIGHTING

A. Applicability 1. General a. No permit for the construction, reconstruction, extension, or alteration of any building, structure, or use of land, and no building or land, or any part of any building or land, may be occupied or used until lighting has been provided in accordance with the requirements of this Code. b. The installation of site lighting, replacement of site lighting, and changes to existing light fixture wattage, type of fixture, mounting, or fixture location must be made in compliance with this Code. Routine maintenance, including changing the lamp, ballast, starter, photo control, fixture housing, lens and other required components, is allowed for all existing fixtures. c. This Section does not apply to lighting installed in the public right-of-way. 2. Additions a. When a building or site is renovated, any new or replaced outdoor light or lighting fixture must conform to the requirements of this Code. b. When the gross floor area or improved site area is increased, the additional floor or site area must conform to the lighting requirements of this Code. c. When the gross floor area or improved site area is increased by more than 50% cumulatively, both the existing use and the additional floor or site area must conform to the lighting requirements of this Code. 3. Change in Use A change in use does not trigger application of this Section. B. Light Level Measuring 1. Light levels are specified, calculated and measured in footcandles. All footcandles values are maintained footcandles. 2. Measurements are to be made at ground level, with the light-registering portion of the meter held parallel to the ground pointing up. C. Prohibited Sources The following light fixtures and sources cannot be used: 1. Cobra-head-type fixtures having dished or drop lenses or refractors, which contain sources that are not incandescent; 2. Temporary searchlights and other high-intensity narrow-beam fixtures; and 3. Light sources that lack color correction or do not allow for uniform site lighting. D. Design and Installation Requirements 1. The maximum light level of any light fixture cannot exceed 2.0 footcandles measured at the right-of-way line of a street. 2. Lighting must not be oriented onto adjacent properties, streets or sidewalks. 3. Service connections for all freestanding lighting fixtures must be installed underground. E. Parking and Pedestrian Areas 1. Light fixtures within parking and vehicular display areas may be no higher than 30 feet. 2. Light fixtures within pedestrian areas may be no higher than 15 feet. ![Figure: AppB-7-2-9E2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/417533b8833ce2bcb1d25962e987b528081dd2039e13477eb23809fdde3bd01e-AppB-7-2-9E2.png) 3. Light fixtures located within 50 feet of the property line of a residential district may be no higher than 15 feet. 4. All light fixtures must be full cutoff, except as listed in paragraph 6. below. ![Figure: AppB-7-2-9E4.png](https://figures.74-208-44-221.nip.io/knoxville/497059/4122e55ab75ca90d4730b51424b830c34143ff7f5f222c0090ae570a0182a840-AppB-7-2-9E4.png) 5. Non-cutoff (unshielded) fixtures can be used when the maximum initial lumens generated by each fixture is less than 9500 initial lamp lumens. These fixtures generally feature globes or vertical glass planes and must be coated with an internal white frosting to diffuse light. ![Figure: AppB-7-2-9E5.png](https://figures.74-208-44-221.nip.io/knoxville/497059/e90c00a64cee06d79d737fe3b21b822afbaec279660746eed24eef9e63d294b3-AppB-7-2-9E5.png) F. Flood Lights and Flood Lamps 1. Flood light fixtures must either be aimed down at least 45 degrees from vertical, or the front of the fixture shielded so that no portion of the light bulb extends below the bottom edge of the shield. ![Figure: AppB-7-2-9F1.png](https://figures.74-208-44-221.nip.io/knoxville/497059/de27037cb0701eb0af6216a68546138fba6efa7e1acf11d350493a389c10e4af-AppB-7-2-9F1.png) 2. Any flood light fixture located within 50 feet of a street right-of-way must be mounted and aimed perpendicular to the right-of-way, with a side-to-side horizontal aiming tolerance not to exceed 15 degrees. ![Figure: AppB-7-2-9F2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/04b7f999629e28e93793d7e6b7593e74859fc954718b471d7d0b2202917089cc-AppB-7-2-9F2.png) 3. All flood lamps emitting 1,000 or more lumens must be aimed at least 60 degrees down from horizontal, or shielded so that the main beam is not visible from adjacent properties or the street right-of-way. ![Figure: AppB-7-2-9F3.png](https://figures.74-208-44-221.nip.io/knoxville/497059/588739474b18a996a96ad7776d364b564ec86d5b9cb78a862aee3f6c93cf8fc8-AppB-7-2-9F3.png) G. Vehicular Canopies Lighting under vehicular canopies must be less than 24 maintained footcandles, and be designed to prevent glare off-site. Acceptable lighting designs include the following: 1. Recessed fixture incorporating a lens cover that is either recessed or flush with the bottom surface of the canopy; ![Figure: AppB-7-2-9G1.png](https://figures.74-208-44-221.nip.io/knoxville/497059/535bf010c54da04bf4b7a62d13591a607a2b79c176510b5d065a8f6df34f0714-AppB-7-2-9G1.png) 2. Light fixture incorporating shields, or is shielded by the edge of the canopy itself, so that light is restrained to 5 degrees or more below the horizontal plane; ![Figure: AppB-7-2-9G2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/71b98eeadedea8c5e343b40591538565265c19cb63e8212a3a3fbe53ff03b5ec-AppB-7-2-9G2.png) 3. Surface mounted fixture incorporating a flat glass that provides a cutoff design or shielded light distribution; or ![Figure: AppB-7-2-9G3.png](https://figures.74-208-44-221.nip.io/knoxville/497059/4a8aef622136118bb851b0a346f894dcdf5cd8dc7396972362bdc6c519ad7864-AppB-7-2-9G3.png) 4. Indirect lighting where light is beamed upward and then reflected down from the underside of the canopy, provided the fixture is shielded so that direct illumination is focused exclusively on the underside of the canopy. ![Figure: AppB-7-2-9G4.png](https://figures.74-208-44-221.nip.io/knoxville/497059/b24827dfccf62508bc647a742888acee651bcc1df2a353da325389f2adb15489-AppB-7-2-9G4.png) H. Building Lighting 1. Lighting fixtures must be selected, located, aimed, and shielded so that direct illumination is focused exclusively on the building façade, plantings, and other intended site features and away from adjoining properties and the street right-of-way. 2. All wall pack fixtures must be full cutoff fixtures. ![Figure: AppB-7-2-9H2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/31d3bed245c35fbbee4e7ed57cadfda5b062d61584c1122128d59003d8a30eaa-AppB-7-2-9H2.png) a. Only lighting used to accent architectural features, landscaping or art may be directed upward, provided that the fixture is located, aimed or shielded to minimize light spill into the night sky.

Ask a question about Knoxville law

Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.