For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7.2.3 — LOT CONFIGURATION

Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Zoning Code, art. 7, § 7.2.3

Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/9eb3577e-bb16-4adf-8b65-60a709e3feaf

7.2.3. - LOT CONFIGURATION

A. Lake Avenue (CU-1) The following lot configuration standards apply within the Lake Avenue (CU-1) district. 1. Lot ![Figure: AppB-7-2-3-A1.png](https://figures.74-208-44-221.nip.io/knoxville/497059/b82718d85bb35bda6271f393aa7dfd8a57c7d93d2ac424f0ea5623b954126075-AppB-7-2-3-A1.png) Lot Standards | Ⓐ Lot width (min) | 16' Building Setbacks | Ⓑ Primary street (min) | 5' Ⓒ Side street (min) | 5' Ⓓ Side interior (min) | 0' or 5' Ⓔ Rear (min) | 10' Ⓕ Rear alley (min) | 5' 2. Placement ![Figure: AppB-7-2-3-A2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/16c7a32dd1b6f38e130e0c95a11ee241b3fc8492508ff154f168124da5e0594e-AppB-7-2-3-A2.png) Build-to Zone (BTZ) | Ⓐ Primary street (min/max) | 5'/15' Ⓑ Building in primary street BTZ (min % of lot width) | 70% Ⓒ Side street (min/max) | 5'/10' Ⓓ Building in side street BTZ (min % of lot width) | 35% Parking Setbacks | Ⓔ Primary street (min) | 10' Ⓕ Side street (min) | 10' Ⓖ Side interior (min) | 0' or 5' Ⓗ Rear (min) | 10' Ⓗ Rear alley (min) | 0' or 5' Outdoor Amenity Space | Ⓘ % of outdoor amenity space (min) | 15% 3. Height ![Figure: AppB-7-2-3-A3.png](https://figures.74-208-44-221.nip.io/knoxville/497059/b69eb4b48f50685ca751f89df0a0a2a206d6eaece00858beb2fb76c0f3a33f05-AppB-7-2-3-A3.png) Building Height | Ⓐ Building height (max) | 120'/10 stories Ⓑ Building height (min) | 24'/2 stories Building Mass | Ⓒ Stepback above 2nd or 3rd story (min) | 10' OR | Ⓓ Façade length without offset (max) | 50' Ⓔ Wall offset depth (min) | 4' Ⓕ Wall offset length (min) | 8' Story Height | Ⓖ Ground story height, floor to ceiling | Residential (min) | 9' Nonresidential (min) | 10' Ⓗ Upper story height, floor to ceiling (min) | 9' Ground Floor Elevation | Ⓘ Residential (min) | 2' Ⓘ Nonresidential (min) | 0' 4. Activation ![Figure: AppB-7-2-3-A4.png](https://figures.74-208-44-221.nip.io/knoxville/497059/90d907b2b713121d779637e8c29b868672b0cd24e4de1682c17c41c25d38f119-AppB-7-2-3-A4.png) Transparency | Ⓐ Ground story (min) | 40% Ⓑ Upper story (min) | 20% Ⓒ Blank wall area (max) | 30' Building Entrances | Ⓓ Primary street facing entrance | Required Ⓔ Entrance spacing (max) | 100' Allowed Building Elements | Porch | yes Stoop | yes Balcony | yes Gallery | yes Awning/canopy | yes Forecourt | yes B. Cumberland Avenue (CU-2) The following lot configuration standards apply within the Cumberland Avenue (CU-2) district. 1. Lot ![Figure: AppB-7-2-3-B1.png](https://figures.74-208-44-221.nip.io/knoxville/497059/73380a8f02303472a5c4c2760315f8587fb986c01c648d145117c087098b264a-AppB-7-2-3-B1.png) Lot Standards | Ⓐ Lot width (min) | 25' Building Setbacks | Ⓑ Primary street (min) | 0' Ⓒ Side street (min) | 0' Ⓓ Side interior (min) | 0' or 5' Ⓔ Rear (min) | 10' Ⓕ Rear alley (min) | 5' 2. Placement ![Figure: AppB-7-2-3-B2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/559c05b6161bf78834f7c8aa6a14d550fa79e18b490bb9425fd42ac8062ed8ee-AppB-7-2-3-B2.png) Build-to Zone (BTZ) | Ⓐ Primary street (min/max) | 0'/10' Ⓑ Building in primary street BTZ (min % of lot width) | 80% Ⓒ Side street (min/max) | 0'/10' Ⓓ Building in side street BTZ (min % of lot depth) | 40% Parking Setbacks | Ⓔ Primary street (min) | 30' Ⓕ Side street (min) | 10' Ⓖ Side interior (min) | 0' or 5' Ⓗ Rear (min) | 10' Ⓗ Rear alley (min) | 0' or 5' Outdoor Amenity Space | Ⓘ % of outdoor amenity space (min | 10% 3. Height ![Figure: AppB-7-2-3-B3.png](https://figures.74-208-44-221.nip.io/knoxville/497059/1b5356fa9c51fd82f8ba86710987fc2d45d521ba3517a3bd5b06d582c823585c-AppB-7-2-3-B3.png) Building Height | Ⓐ Building height (max) | 90'/8 stories Ⓑ Building height (min) | 24'/2 stories Building Mass | Ⓒ Stepback above 2nd or 3rd story (min) | 10' Story Height | Ⓓ Ground story height, floor to ceiling (min) | 12' Ⓔ Upper story height, floor to ceiling (min) | 9' Ground Floor Elevation | Ⓕ Residential (min) | N/A Ⓕ Nonresidential (min) | 0' 4. Activation ![Figure: AppB-7-2-3-B4.png](https://figures.74-208-44-221.nip.io/knoxville/497059/1aa8f903825cabe6e4434cd3ddca000aa415d195ec24fb5537308ac8740f407c-AppB-7-2-3-B4.png) Transparency | Ⓐ Ground story (min) | 75% Ⓑ Upper story (min) | 20% Ⓒ Blank wall area (max) | 20' A minimum of 60% of the ground floor windows must allow views into the ground story for a depth of at least 8 feet. Windows cannot be made opaque by window treatments (except operable sunscreen devices within the conditioned space). | Building Entrances | Ⓓ Primary street facing entrance | Required Ⓔ Entrance spacing (max) | 50' Allowed Building Elements | Porch | no Stoop | no Balcony | yes Gallery | yes Awning/canopy | yes Forecourt | yes C. White Avenue/Hospital (CU-3) The following lot configuration standards apply within the White Avenue/Hospital (CU-3) district. 1. Lot ![Figure: AppB-7-2-3-C1.png](https://figures.74-208-44-221.nip.io/knoxville/497059/9db11925db2555c5df48c387161c082d71ba379e35924656e99865f926a44961-AppB-7-2-3-C1.png) Lot Standards | Ⓐ Lot width (min) | 16' Building Setbacks | Ⓑ Primary street (min) | 5' Ⓒ Side street (min) | 5' Ⓓ Side interior (min) | 0' or 5' Ⓔ Rear (min) | 10' Ⓕ Rear alley (min) | 5' 2. Placement ![Figure: AppB-7-2-3-C2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/656656d78a137e7e185762991458098fe9bf40037318a22d4057ee731f4a51ff-AppB-7-2-3-C2.png) Build-to Zone (BTZ) | Ⓐ Primary street (min/max) | 5'/15' Ⓑ Building in primary street BTZ (min % of lot width) | 70% Ⓒ Side street (min/max) | 5'/10' Ⓓ Building in side street BTZ (min % of lot width) | 35% Parking Setbacks | Ⓔ Primary street (min) | 10' Ⓕ Side street (min) | 10' Ⓖ Side interior (min) | 0' or 5' Ⓗ Rear (min) | 10' Ⓗ Rear alley (min) | 0' or 5' Outdoor Amenity Space | Ⓘ % of outdoor amenity space (min) | 15% 3. Height ![Figure: AppB-7-2-3-C3.png](https://figures.74-208-44-221.nip.io/knoxville/497059/15b472d5cae06de3a9cb2f86ab0b35cf8dcb7886a8ccfd9f5fae2481ddcc3d0e-AppB-7-2-3-C3.png) Building Height | Ⓐ Building height (max) | 90'/8 stories Ⓑ Building height (min) | 24'/2 stories Story Height | Ⓒ Ground story height, floor to ceiling (min) | Residential (min) | 9' Nonresidential (min) | 10' Ⓓ Upper story height, floor to ceiling (min) | 9' Ground Floor Elevation | Ⓔ Residential (min) | 2' Ⓔ Nonresidential (min) | 0' 4. Activation ![Figure: AppB-7-2-3-C4.png](https://figures.74-208-44-221.nip.io/knoxville/497059/f50b701eecefdb0f3ab8d862d3345f8fbe23bb240d11231d3965f8a75354386e-AppB-7-2-3-C4.png) Transparency | Ⓐ Ground story (min) | 40% Ⓑ Upper story (min) | 20% Ⓒ Blank wall area (max) | 30' Building Entrances | Ⓓ Primary street facing entrance | Required Ⓐ Entrance spacing (max) | 100' Allowed Building Elements | Porch | yes Stoop | yes Balcony | yes Gallery | yes Awning/canopy | yes Forecourt | yes D. White Avenue/Neighborhood (CU-4) The following lot configuration standards apply within the White Avenue/Neighborhood (CU-4) district. 1. Lot ![Figure: AppB-7-2-3-D1.png](https://figures.74-208-44-221.nip.io/knoxville/497059/02fc69418db6629cf5f4e9a3cd84b502cbb36015004458ab84fec1ffd64d8595-AppB-7-2-3-D1.png) Lot Standards | Ⓐ Lot width (min) | 16' Building Setbacks | Ⓑ Primary street (min) | 5' Ⓒ Side street (min) | 5' Ⓓ Side interior (min) | 5' Ⓔ Rear (min) | 10' Ⓕ Rear alley (min) | 5' 2. Placement ![Figure: AppB-7-2-3-D2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/e481e119a8f2c11ca11bc572c267c6440dc28ec41e66e600d1d9abf326d60115-AppB-7-2-3-D2.png) Build-to Zone (BTZ) | Ⓐ Primary street (min/max) | 5'/20' Ⓑ Building in primary street BTZ (min % of lot width) | 60% Ⓒ Side street (min/max) | 5'/10' Ⓓ Building in side street BTZ (min % of lot width) | 30% Parking Setbacks | Ⓔ Primary street (min) | 10' Ⓕ Side street (min) | 10' Ⓖ Side interior (min) | 5' Ⓗ Rear (min) | 10' Ⓗ Rear alley (min) | 5' Outdoor Amenity Space | Ⓘ % of outdoor amenity space (min) | 20% 3. Height ![Figure: AppB-7-2-3-D3.png](https://figures.74-208-44-221.nip.io/knoxville/497059/5e784c89f2cc227ca457cc5db5403f518cf8a6ae9429f9d350490bfdd1d8cabb-AppB-7-2-3-D3.png) Building Height | Ⓐ Building height (max) | 50'/4 stories Ⓑ Building height (min) | 24'/2 stories Building Mass | Ⓒ Façade length without offset (max) | 50' Ⓓ Wall offset depth (min) | 10' Ⓔ Wall offset length (min) | 20' Story Height | Ⓕ Ground story height, floor to ceiling | 9' Ⓖ Upper story height, floor to ceiling (min) | 9' Ground Floor Elevation | Ⓗ Residential (min) | 2' Ⓗ Nonresidential (min) | 0' 4. Activation ![Figure: AppB-7-2-3-D4.png](https://figures.74-208-44-221.nip.io/knoxville/497059/5630c2a3badb6d4e615eecf90f76ff6585df67e8b74f40e930b9049b1eaf2090-AppB-7-2-3-D4.png) Transparency | Ⓐ Ground story (min) | 20% Ⓑ Upper story (min) | 20% Ⓒ Blank wall area (max) | 20' Building Entrances | Ⓓ Primary street facing entrance | Required Ⓔ Entrance spacing (max) | 100' Allowed Building Elements | Porch | yes Stoop | yes Balcony | yes Gallery | yes Awning/canopy | yes Forecourt | yes E. Seventeenth Street (CU-5) The following lot configuration standards apply within the Seventeenth Street (CU-5) district. 1. Lot ![Figure: AppB-7-2-3-E1.png](https://figures.74-208-44-221.nip.io/knoxville/497059/e9aa0afe67576f5eaeed9aab667beaa8eee667c1e003873c980d14b7385b8618-AppB-7-2-3-E1.png) Lot Standards | Ⓐ Lot width (min) | 16' Building Setbacks | Ⓑ Primary street (min) | 5' Ⓒ Side street (min) | 5' Ⓓ Side interior (min) | 0' or 5' Ⓔ Rear (min) | 10' Ⓕ Rear alley (min) | 5' 2. Placement ![Figure: AppB-7-2-3-E2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/76e26132c69a97464701d816b106a78e6b0d2edf3d5fcb2f033e23a6a4dc451c-AppB-7-2-3-E2.png) Build-to Zone (BTZ) | Ⓐ Primary street (min/max) | 5'/15' Ⓑ Building in primary street BTZ (min % of lot width) | 70% Ⓒ Side street (min/max) | 5'/10' Ⓓ Building in side street BTZ (min % of lot width) | 35% Parking Setbacks | Ⓔ Primary street (min) | 10' Ⓕ Side street (min) | 10' Ⓖ Side interior (min) | 0' or 5' Ⓗ Rear (min) | 10' Ⓗ Rear alley (min) | 0' or 5' Outdoor Amenity Space | Ⓘ % of outdoor amenity space (min) | 15% 3. Height ![Figure: AppB-7-2-3-E3.png](https://figures.74-208-44-221.nip.io/knoxville/497059/2436ac90f2ed3e48e8793b29ac6b77c6ebcf3afcb91a8991cf1fb0f2e0d00ea5-AppB-7-2-3-E3.png) Building Height | Ⓐ Building height (max) | 90'/8 stories Ⓑ Building height (min) | 24'/2 stories Building Mass | Ⓒ Stepback above 2nd or 3rd story (min) | 10' OR | Ⓓ Façade length without offset (max) | 50' Ⓔ Wall offset depth (min) | 4' Ⓕ Wall offset length (min) | 8' Story Height | Ⓖ Ground story height, floor to ceiling (min) | 12' Ⓗ Upper story height, floor to ceiling (min) | 9' Ground Floor Elevation | Ⓘ Residential (min) | 2' Ⓘ Nonresidential (min) | 0' 4. Activation ![Figure: AppB-7-2-3-E4.png](https://figures.74-208-44-221.nip.io/knoxville/497059/835d9a4d90cb99bedac06ac5224c9327a9e4b6eff4bb95d44b6321e53bfe33c7-AppB-7-2-3-E4.png) Transparency | Ⓐ Ground story (min) | 75% Ⓑ Upper story (min) | 20% Ⓒ Blank wall area (max) | 20' A minimum of 60% of the ground floor windows must allow views into the ground story for a depth of at least 8 feet. Windows cannot be made opaque by window treatments (except operable sunscreen devices within the conditioned space). | Building Entrances | Ⓓ Primary street facing entrance | Required Ⓔ Entrance spacing (max) | 50' Allowed Building Elements | Porch | yes Stoop | yes Balcony | yes Gallery | yes Awning/canopy | yes Forecourt | yes

Ask a question about Knoxville law

Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.