§ 7.1.3 — PROPERTY DEVELOPMENT STANDARDS BY DISTRICT
Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Zoning Code, art. 7, § 7.1.3
Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/a265a69d-7042-43af-801a-2027b3ef2ca8
7.1.3. - PROPERTY DEVELOPMENT STANDARDS BY DISTRICT
A. Check List | Complies | Complies with Administrative Deviation | Does Not Comply | N/A VISION & INTENT | | | | Statement | □ | □ | □ | □ DEVELOPMENT STANDARDS | | | | Existing Conditions | | | | Topography | □ | □ | □ | □ Existing Trees | □ | □ | □ | □ 100-Year Flood Lines | □ | □ | □ | □ 500-Year Flood Lines | □ | □ | □ | □ Environmental & Archeological | □ | □ | □ | □ Block Layout | | | | Block Size | □ | □ | □ | □ Building Lines: | | | | River Buffer Setback | □ | □ | □ | □ Stream Buffer Setback | □ | □ | □ | □ Proposed Subdivision & Phasing | □ | □ | □ | □ Buildings Siting & Configuration | | | | Principal Building Siting: | | | | Orientation | □ | □ | □ | □ Front Setback | □ | □ | □ | □ Frontage at Setback | □ | □ | □ | □ Side Setback | □ | □ | □ | □ Rear Setback | □ | □ | □ | □ Lot Size | □ | □ | □ | □ Building Coverage | □ | □ | □ | □ Open Space Coverage | □ | □ | □ | □ Principle Building Configuration: | | | | Building Width | □ | □ | □ | □ Building Height Min | □ | □ | □ | □ Building Height Max | □ | □ | □ | □ Footprint/Floor Plate | □ | □ | □ | □ Floor Area Ratio (FAR) | □ | □ | □ | □ Ancillary Structures & Outdoor Spaces | | | | Ancillary/Accessory Structures | □ | □ | □ | □ Ancillary Structure Envelope: | | | | Footprint/Floor Plate | □ | □ | □ | □ Front Setback | □ | □ | □ | □ Side Setback | □ | □ | □ | □ Rear Setback | □ | □ | □ | □ Building Height | □ | □ | □ | □ Outdoor Space Types | □ | □ | □ | □ Usable Private Outdoor Area | □ | □ | □ | □ Building Frontages | | | | Building Frontages | □ | □ | □ | □ Building Entries | □ | □ | □ | □ Building Envelope Articulation: | | | | Ground Level | □ | □ | □ | □ Façade Length | □ | □ | □ | □ Façade Openings | □ | □ | □ | □ Roofs | □ | □ | □ | □ Other | □ | □ | □ | □ Building Function | □ | □ | □ | □ Off Street Parking & Loading | | | | Parking Types | □ | □ | □ | □ Parking Spaces, Reserved & Shared | □ | □ | □ | □ Pavements | □ | □ | □ | □ Garage Location | □ | □ | □ | □ Screening & Shading | □ | □ | □ | □ Accessible Spaces & Routes | □ | □ | □ | □ Driveways & Curb Cuts | □ | □ | □ | □ Garage Entry | □ | □ | □ | □ Service Loading | □ | □ | □ | □ Bicycle Parking | □ | □ | □ | □ External Elements | | | | Proposed Topography Grades | □ | □ | □ | □ Side or Rear Privacy Fence or Wall | □ | □ | □ | □ Front Fence or Wall | □ | □ | □ | □ Landscaped Vegetation | | | | Trees | □ | □ | □ | □ Shrubs & Groundcover | □ | □ | □ | □ Slopes | □ | □ | □ | □ Trash Storage & Recycling | □ | □ | □ | □ External Mechanical & Electrical Units | □ | □ | □ | □ Signs | □ | □ | □ | □ Lighting Trespass | □ | □ | □ | □ Sustainability | | | | Green Building & Landscape | □ | □ | □ | □ Reflectivity | □ | □ | □ | □ B. SW1 Old Sevier and Scottish Pike  1. Vision and Intent The Old Sevier and Scottish Pike areas are envisioned to conserve the "small town, neighborhood" atmosphere. New developments in these areas are encouraged to preserve and extend the existing neighborhood character and to maintain a complementary scale and density. Large-scale assemblage of residential properties or any commercial uses are prohibited. Suggested building types include detached houses, cottages, duplex houses, attached townhouses and rowhouses. New street alignments in combination with the existing roads define important access and view corridors to the river and the bluffs. The completed road network establishes a "figure eight" loop by adding a new rail underpass to connect to August Avenue en route to Vestal. The road network links Blount Avenue to the new Waterfront Drive (east of the Gay Street Bridge) then to Sevier Avenue and Augusta Avenue. In order to alleviate Blount Avenue from congestion associated with new development, improvements to Augusta Avenue change the character of this street from a tertiary street to a significant boulevard with a bus route and close relationship to the rail line. Scottish Pike will enjoy new access to Fort Dickerson Park and a newly landscaped green corridor of Goose Creek. Proposed street right-of-ways improve pedestrian circulation as well as integrate street trees.  2. Existing Conditions a. Intent Guide site survey to assess existing site conditions for constraints and opportunities. Maintain views to river and downtown when viewed from hills behind. b. Topography Consider existing topography and provide topographic survey with 2-foot contours. c. Existing Trees i. Identify all existing trees with a 6-inch minimum caliper including root zone within dripline. ii. Preserve a minimum of 1 healthy large canopy tree per lot, or 6 healthy trees per acre, whichever is greater. d. Environmental and Archaeological i. Comply with State and Federal requirements. 3. Block Layout a. Intent Guide lot layout and outline the maximum block perimeter and building setbacks permitted in this district to ensure walkable neighborhoods. b. Block Size Maximum perimeter of 1,400 feet. c. Building Lines i. Minimum of 70 feet from normal pool EL 813.0. Refer to Sec. 7.1.6, Riverscape Standards. d. Proposed Subdivision and Phasing Plan Clearly designate future phases and describe proposed subdivision plan and phasing when applicable. 4. Building Siting and Configuration Intent: Provide building configuration and design parameters.  Principal Building Siting | Orientation | NA Front Setback (min/max) | 10'/25' Frontage at Setback (min) | 40% (excluding single-family or duplexes) Side Setback (min) | 5' Rear Setback (min) | 10' Lot Size (max) | 15,000 SF Building Coverage (max) | 30% (including accessory structures) Open Space Coverage (min) | 70% Principal Building Configuration | Building Width (min) | 20' Building Height (min) | NA Building Height (max) | 35' & 2.5 Stories Footprint/Floor Plate | NA Floor Area Ratio (max) | 1 5. Ancillary Structures and Outdoor Spaces Intent: Provide outdoor space configuration and design parameters.  Ancillary/Accessory Structures | Rear studio, detached garage, workshop, live/work unit, accessory dwelling unit, gazebo, garden shed | Ancillary/Accessory Structure Envelope | Footprint/Floor Plate (max) | 650 SF Front Setback | 10' + Building Setback Frontage at Setback | NA Side Setback (min) | 5' Rear Setback (min) | 10' Building Width | NA Building Height (max) | 25' and 2 Story Outdoor Space Types | Front yard, side yard, rear yard, gardens | Usable Private Open Space | 400 SF (min) | 6. Building Frontages Frontage Typologies: Refer to Sec. 7.1.4.C.  Building Entries | Primary entry on principal frontage | Building Envelope Articulation | Ground Level | NA Façade Length | NA Façade Openings | Openings on the principal frontage shall be min 25% of the building wall area Roofs | Buildings may have flat or sloped roofs Other | Balconies, porches, bay windows and other projections are encouraged and may be incorporated into the building setback Building Function | Household Living | Places of Worship, Schools and Day cares may be considered on a use on review basis | 7. Off Street Parking and Loading Intent: Provide with adequate parking to accommodate the district's various building types and functions. Refer to Sec. 7.1.4.D.  a. Parking Types Surface or Garage. b. Parking Spaces, Reserved and Shared Minimum of 1 parking space per unit; Maximum of 2 parking spaces per unit. c. Pavements 65% minimum of uncovered surface parking shall be permeable while meeting overall stormwater requirements. d. Garage Location Setback 10 feet further than building. e. Screening and Shading One tree (with a 2-inch minimum caliper) is required for every 5 surface parking spaces. f. Accessible Spaces and Routes Meet or exceed city accessibility standards. g. Driveways i. One on any frontage with a 15-foot maximum for one way traffic and 26-foot maximum for two way traffic. ii. Sidewalk materials and patterning is continuous through driveway. h. Garage Entry One on any frontage. i. Service Loading Not permitted. j. Bicycle Parking Not required. 8. External Elements a. Intent Guide the integration of external elements into property development including landscaping, utilities and lighting. Refer to Sec. 7.1.4.E, Signage and Sec. 7.1.4.F, Lighting and Noise. b. Proposed Topography Grades Provide grading plan with 2-foot contours. c. Side or Rear Privacy Fence or Wall Maximum of 8 feet. d. Front Fence or Wall Maximum of 3 feet 6 inches in front yard or streetside of corner lot. e. Landscape Vegetation i. Minimum of 8 trees (with a 2-inch minimum caliper) per acre of area not covered by buildings. ii. Trees required for surface parking may be counted toward overall landscape requirement. f. Trash/Recycling Storage, External Mechanical Units, Electrical Units and Rain Barrels Integrate with building design or screen/conceal from view from public street and riverwalk. g. Signage House number. 9. Sustainability a. Intent Encourage longevity, durability, energy and economic efficiency as well as improved environmental conditions. b. Green Building and Landscape i. Capable of attaining the current Leadership in Energy and Environmental Design (LEED) minimal Performance Level of "Certified." ii. Submit completed worksheet of appropriate LEED standard to demonstrate pre-certification estimate. c. Reflectivity, Heat Island Reduction, Roof and Surface Lots i. Surface lots shall provide shade and/or use light-colored/high albedo materials with a solar reflectance of at least 0.3 (30%). ii. Roofs shall use an Energy Star Compliant (highly reflective) for a minimum of 75% of the roof surface. C. SW2 River Rd, Goose Creek Row and Island Home Ave  1. Vision and Intent The neighborhoods of Goose Creek, Waterfront Drive and Island Home Avenue are envisioned to have new, predominantly residential developments along the waterfront that will create a contemporary identity for the Knoxville South Waterfront. Suggested building types include duplex houses, townhouses, rowhouses and multiple unit housing. With a newly landscaped shoreline experience and a continuous riverfront setback along the river's edge, these developments provide residents spectacular vistas of the river but minimize obstructed views perpendicular to the river. The proposed River Street will be layered with modes of two-direction travel—bike lanes, on-street parking, a wide sidewalk and a well-landscaped river walk. River Street will be an important part of the "figure eight" road network making a loop from Gay Street to Sevier and Phillips Avenues. A continuous promenade forms the northern edge of the river arboretum—the major open space of the area located in the flood plain. Residents enjoy access to a wealth of waterfront and water-based recreational activities. While these neighborhoods are primarily residential, they are located adjacent to highly-accessed public parks that boast many visitors on a daily basis and during city-wide events. Residents have access to the newly landscaped Goose Creek Green Corridor with a direct link to Fort Dickerson Quarry. Public access to the river is created along axes following the north-south streets, while on-street parking accommodates visitors to the parks and various recreational facilities. A bridge connection to the University may link the two sides of the river.  2. Existing Conditions a. Intent Guide site survey to assess existing site conditions for constraints and opportunities. Direct views to river and downtown, when viewed from neighborhoods behind. b. Topography Consider existing topography and provide topographic survey with 2-foot contours. c. Existing Trees i. Identify all existing trees with a 6-inch minimum caliper including root zone within dripline. ii. Preserve a minimum of 1 healthy large canopy tree per lot, or 6 healthy trees per acre, whichever is greater. d. Environmental and Archaeological i. Comply with State and Federal Requirements. 3. Block Layout a. Intent Guide lot layout and outline the maximum block perimeter and building setbacks permitted in this district to ensure walkable neighborhoods. b. Block Size Maximum perimeter of 1,400 feet. c. Building Lines i. Minimum of 70 feet from normal pool EL 813.0. Refer to Sec. 7.1.6, Riverscape Standards. d. Proposed Subdivision and Phasing Plan Clearly designate future phases and describe proposed subdivision plan and phasing when applicable. 4. Building Siting and Configuration Intent: Provide building configuration and design parameters, as well as suggestions for building function.  Principal Building Siting | Orientation | NA Front Setback (max) | 10' Frontage at Setback (min) | 75% Side Setback (max) | 25' Rear Setback (min) | 3' Lot Size (max) | 3 acres Building Coverage (max) | 70% Open Space Coverage (min) | 30% Principal Building Configuration | Building Height (min) | 25' & 2 Story Building Height (max) | 40' & 3 Stories plus 10' and 1 Story max at Setback + 10' Footprint/Floor Plate | NA Floor Area Ratio (max) | 3 5. Ancillary Structures and Outdoor Spaces Intent: Provide outdoor space configuration and design parameters.  Ancillary/Accessory Structures | Rear studio, detached garage, workshop, live/work unit, accessory dwelling unit, gazebo, garden shed | Ancillary/Accessory Structure Envelope | Footprint/Floor Plate (max) | 650 SF Front Setback | 10' + Building Setback Frontage at Setback | NA Side Setback | NA Rear Setback (min) | 3' Building Width | NA Building Height (max) | 25' and 2 Story Outdoor Space Types | Front yard, side yard, rear yard, roof decks, terraces, sport courts | Usable Private Open Space | 400 SF (min) | 6. Building Frontages Frontage Typologies: Refer to Sec. 7.1.4.C.  Building Entries | Primary entry on principal frontage | Building Envelope Articulation | Ground Level | NA Façade Length | Façades longer than 30' shall be divided in a vertically distinguishable manner Façade Openings | Openings on the principal frontage shall be min 25% of the building wall area Roofs | Buildings may have flat or sloped roofs Other | Balconies, porches, bay windows and other projections are encouraged and may be incorporated into the building setback 7. Off Street Parking and Loading Intent: Provide with adequate parking to accommodate the district's various building types and functions. Refer to Sec. 7.1.4.D.  a. Parking Types Surface lot, garages, under building garage. b. Parking Spaces, Reserved and Shared Maximum of 3 parking spaces per 1,000 square feet and maximum of 2 parking spaces per residential unit. c. Pavements 65% minimum of uncovered surface parking shall be permeable while meeting overall stormwater requirements. d. Garage Location To rear of property or underneath building. e. Screening and Shading One tree (with a 2-inch minimum caliper) is required for every 5 surface parking spaces. f. Accessible Spaces and Routes Meet or exceed city accessibility standards. g. Driveways i. Not permitted on principal frontage and shall be 15-foot maximum for one way traffic and 26-foot maximum for two way traffic. ii. Sidewalk materials and patterning is continuous through driveway. h. Garage Entry From rear alley or side street. i. Service Loading Permitted from rear alley or side street. j. Bicycle Parking Required. 8. External Elements Intent: Guide the integration of external elements into property development including landscaping, utilities and lighting. Refer to Sec. 7.1.4.E, Signage and Sec. 7.1.4.F, Lighting and Noise.  a. Proposed Topography Grades Provide grading plan with 2-foot contours. b. Side or Rear Privacy Fence or Wall Maximum of 8 feet. c. Front Fence or Wall Maximum of 3 feet 6 inches. d. Landscape Vegetation i. Minimum of 8 trees (with a 2-inch minimum caliper) per acre of open space. ii. Trees required for surface parking may be counted toward overall landscape requirement. e. Trash/Recycling Storage, External Mechanical Units, Electrical Units and Rain Barrels Integrate with building design or screen/conceal from view from public street and riverwalk. 9. Sustainability a. Intent Encourage longevity, durability, energy and economic efficiency as well as improved environmental conditions. b. Green Building and Landscape i. Capable of attaining the current Leadership in Energy and Environmental Design (LEED) minimal Performance Level of "Certified." ii. Submit completed worksheet of appropriate LEED standard to demonstrate pre-certification estimate. c. Reflectivity, Heat Island Reduction, Roof and Surface Lots i. Surface lots shall provide shade and/or use light-colored/high albedo materials with a solar reflectance of at least 0.3 (30%). ii. Roofs shall use an Energy Star Compliant (highly reflective) for a minimum of 75% of the roof surface. D. SW3 Sevier Avenue  1. Vision and Intent Sevier Avenue is the historic commercial heart of the Old Sevier neighborhood. It has the potential to fulfill the role of 'Main Street' in the future and become a viable commercial center for the local neighborhoods. New development in this area has a mix of commercial and retail uses on ground floors that promote both daytime and nighttime activities. Developments in this area could also house multiple residential units on the upper floors. The new mixed-use infill development will complement the existing buildings and preserve the historic character that exists. New buildings shall be built up to the street (rather than being setback from the street) to reinforce the continuity of the street wall. Parking for new developments will be to the rear of the site as well as on-street. Existing historic buildings will be encouraged to be restored for reuse. Suggested building types that may exist in this vibrant district include mixed-use shopfront buildings and loft developments. A potential conversion of the freight rail line to light rail may provide public transportation to the area in the future.  2. Existing Conditions and Block Layout a. Intent Guide site survey to assess existing site conditions for constraints and opportunities. b. Topography Consider existing topography and provide topographic survey with 2-foot contours. c. Existing Trees i. Identify all existing trees with a 6-inch minimum caliper including root zone within dripline. ii. Preserve a minimum of 1 healthy large canopy tree per lot, or 6 healthy trees per acre, whichever is greater. d. Environmental and Archaeological i. Comply with State and Federal Requirements. 3. Block Layout a. Intent Guide lot layout and outline the maximum block perimeter and building setbacks permitted in this district to ensure walkable neighborhoods. b. Block Size Maximum perimeter of 1,400 feet. c. Building Lines Minimum of 70 feet from normal pool EL 813.0. Refer to Sec. 7.1.6, Riverscape Standards. d. Proposed Subdivision and Phasing Plan Clearly designate future phases and describe proposed subdivision plan and phasing when applicable. 4. Building Siting and Configuration Intent: Provide building configuration and design parameters, as well as suggestions for building function.  Principal Building Siting | Orientation | NA Front Setback (max) | 10' Frontage at Setback (min) | 75% to Sevier Avenue, 40% to all others Side Setback (max) | 25' Rear Setback (min) | 3' Lot Size (max) | 3 acres Building Coverage (max) | 80% Open Space Coverage (min) | 20% Principal Building Configuration | Building Width | NA Building Height (min) | 25' & 2 Story Building Height (max) | 50' & 4 Stories plus 10' and 1 Story max at Setback + 10' Footprint/Floor Plate (max) | 30,000 SF; Does not apply to structured parking footprint Floor Area Ratio (max) | 4 5. Ancillary Structures and Outdoor Spaces a. Intent Provide outdoor space configuration and design parameters. b. Ancillary/Accessory Structures NA c. Ancillary/Accessory Structure Envelope i. Footprint/Floor Plate: NA ii. Front Setback: NA iii. Frontage at Setback: NA iv. Side Setback: NA v. Rear Setback: NA vi. Building Width: NA vii. Building Height: NA d. Outdoor Space Types Roof decks, patios e. Usable Private Open Space NA 6. Building Frontages Frontage Typologies: Refer to Sec. 7.1.4.C.  Building Entries | Primary entry on principal frontage | Building Envelope Articulation | Ground Level | Min 70% transparent glass at the ground level on principal frontage Façade Length | NA Façade Openings | Openings above the first story on the principal frontage shall be min 25% of the building wall area Roofs | Buildings may have flat or sloped roofs Other | Balconies, porches, bay windows and other projections are encouraged and may be incorporated into the building setback 7. Off Street Parking and Loading Intent: Provide with adequate parking to accommodate the district's various building types and functions. Refer to Sec. 7.1.4.D.  a. Parking Types Surface lot, above ground structure, basement garage. b. Parking Spaces, Reserved and Shared Maximum of 3 parking spaces per 1,000 square feet and maximum of 2 parking spaces per residential unit. c. Pavements 65% minimum of uncovered surface parking shall be permeable while meeting overall stormwater requirements. d. Garage Location To rear of property or underneath building. e. Screening and Shading One tree (with a 2-inch minimum caliper) is required for every 5 surface parking spaces. f. Accessible Spaces and Routes Meet or exceed city accessibility standards. g. Driveways i. Driveway shall be 15-foot maximum for one way traffic and 26-foot maximum for two way traffic. ii. Sidewalk materials and patterning is continuous through driveway. h. Garage Entry Permitted on all frontages. i. Service Loading Permitted. j. Bicycle Parking Required. 8. External Elements Intent: Guide the integration of external elements into property development including landscaping, utilities and lighting. Refer to Sec. 7.1.4.E, Signage and Sec. 7.1.4.F, Lighting and Noise.  a. Proposed Topography Grades Provide grading plan with 2-foot contours. b. Side or Rear Privacy Fence or Wall Maximum of 8 feet. c. Front Fence or Wall Maximum of 3 feet 6 inches. d. Landscape Vegetation i. Minimum of 8 trees (with a 2-inch minimum caliper) per acre of open space. ii. Trees required for surface parking may be counted toward overall landscape requirement. e. Trash/Recycling Storage, External Mechanical Units, Electrical Units and Rain Barrels Integrate with building design or screen/conceal from view from public street and riverwalk. 9. Sustainability a. Intent Encourage longevity, durability, energy and economic efficiency as well as improved environmental conditions. b. Green Building and Landscape i. Capable of attaining the current Leadership in Energy and Environmental Design (LEED) minimal Performance Level of "Certified." ii. Submit completed worksheet of appropriate LEED standard to demonstrate pre-certification estimate. c. Reflectivity, Heat Island Reduction, Roof and Surface Lots i. Surface lots shall provide shade and/or use light-colored/high albedo materials with a solar reflectance of at least 0.3 (30%). ii. Roofs shall use an Energy Star Compliant (highly reflective) for a minimum of 75% of the roof surface. E. SW4 City View, Campus Cove and Quay Village  1. Vision and Intent These three new development districts are clustered around privately-owned but publicly-accessed marinas, lending these areas a distinctively urban character that will enliven the new Knoxville South Waterfront. Higher density and larger in scale, these buildings have a mix of uses, including office, residential, commercial and hospitality. All new developments shall integrate publicly accessible landscapes and plazas that unify the buildings with a setback from the river to accommodate a continuous promenade and marinas. View corridors and public open spaces will connect these areas to the neighborhoods, civic spaces and natural drainage ways to the river. Parking is incorporated into the structures or housed beneath the buildings when possible. Large surface parking lots are discouraged. A possible pedestrian connection to the University of Tennessee will facilitate a continuation of the student population into the Campus Cove. The Sevier Avenue extension from the James White Parkway will be realigned with a traffic circle to improve traffic flow and create a sense of entry into the downtown. A second traffic circle will be introduced along Island Home Avenue.  2. Existing Conditions a. Intent Guide site survey to assess existing site conditions for constraints and opportunities. Direct views to river and downtown, when viewed from neighborhoods behind. b. Topography Consider existing topography and provide topographic survey with 2-foot contours. c. Existing Trees i. Identify all existing trees with a 6-inch minimum caliper including root zone within dripline. ii. Preserve a minimum of 1 healthy large canopy tree per lot, or 6 healthy trees per acre, whichever is greater. d. Environmental and Archaeological Comply with State and Federal Requirements. 3. Block Layout a. Intent Guide lot layout and outline the maximum block perimeter and building setbacks permitted in this district to ensure walkable neighborhoods. b. Block Size Maximum perimeter of 1,400 feet. c. Building Lines Minimum of 70 feet from normal pool EL 813.0. Refer to Sec. 7.1.6, Riverscape Standards. d. Proposed Subdivision and Phasing Plan Clearly designate future phases and describe proposed subdivision plan and phasing when applicable. 4. Building Siting and Configuration Intent: Provide building configuration and design parameters, as well as suggestions for building function.  Principal Building Siting | Orientation | NA Front Setback (max) | 10' Frontage at Setback (min) | 50% Side Setback (max) | 25' Rear Setback (min) | 3' Lot Size (max) | 3 acres Building Coverage (max) | 80% Open Space Coverage (min) | 20% Principal Building Configuration | Building Width | NA Building Height (min) | 25' & 2 Story Building Height (max) | 50' & 4 Story plus 20' and 2 Story max at Setback + 10' Footprint/Floor Plate (max) | 30,000 SF; Does not apply to structured parking footprint Floor Area Ratio (max) | 4 5. Ancillary Structures and Outdoor Spaces a. Intent Provide outdoor space configuration and design parameters. b. Ancillary/Accessory Structures NA c. Ancillary/Accessory Structure Envelope i. Footprint/Floor Plate: NA ii. Front Setback: NA iii. Frontage at Setback: NA iv. Side Setback: NA v. Rear Setback: NA vi. Building Width: NA vii. Building Height: NA d. Outdoor Space Types Courtyards, plazas, pools e. Usable Private Open Space NA 6. Building Frontages Frontage Typologies: Refer to Sec. 7.1.4.C.  Building Entries | Primary entry on principal frontage | Building Envelope Articulation | Ground Level | Min 70% transparent glass at the ground level on principal frontage Façade Length | NA Façade Openings | Openings on the principal frontage shall be min 25% of the building wall area Roofs | Buildings may have flat or sloped roofs Other | Balconies, porches, bay windows and other projections are encouraged and may be incorporated into the building setback 7. Off Street Parking and Loading Intent: Provide with adequate parking to accommodate the district's various building types and functions. Refer to Sec. 7.1.4.D.  a. Parking Types Surface lot, above ground structure, basement garage. b. Parking Spaces, Reserved and Shared Maximum of 3 parking spaces per 1,000 square feet and maximum of 2 parking spaces per residential unit. c. Pavements 65% minimum of uncovered surface parking shall be permeable while meeting overall stormwater requirements. d. Garage Location To rear or side of property or underneath building. e. Screening and Shading One tree (with a 2-inch minimum caliper) is required for every 5 surface parking spaces. f. Accessible Spaces and Routes Meet or exceed city accessibility standards. g. Driveways i. Driveway shall be 15-foot maximum for one way traffic and 26-foot maximum for two way traffic. ii. Sidewalk materials and patterning is continuous through driveway. h. Garage Entry Permitted on all frontages. i. Service Loading Permitted. j. Bicycle Parking Required. 8. External Elements Intent: Guide the integration of external elements into property development including landscaping, utilities and lighting. Refer to Sec. 7.1.4.E, Signage and Sec. 7.1.4.F, Lighting and Noise.  a. Proposed Topography Grades Provide grading plan with 2-foot contours. b. Side or Rear Privacy Fence or Wall Maximum of 8 feet. c. Front Fence or Wall Maximum of 3 feet 6 inches. d. Landscape Vegetation i. Minimum of 8 trees (with a 2-inch minimum caliper) per acre of open space. ii. Trees required for surface parking may be counted toward overall landscape requirement. e. Trash/Recycling Storage, External Mechanical Units, Electrical Units and Rain Barrels Integrate with building design or screen/conceal from view from public street and riverwalk. 9. Sustainability a. Intent Encourage longevity, durability, energy and economic efficiency as well as improved environmental conditions. b. Green Building and Landscape i. Capable of attaining the current Leadership in Energy and Environmental Design (LEED) minimal Performance Level of "Certified." ii. Submit completed worksheet of appropriate LEED standard to demonstrate pre-certification estimate. c. Reflectivity, Heat Island Reduction, Roof and Surface Lots i. Surface lots shall provide shade and/or use light-colored/high albedo materials with a solar reflectance of at least 0.3 (30%). ii. Roofs shall use an Energy Star Compliant (highly reflective) for a minimum of 75% of the roof surface. F. SW5 Bell Tower Walk  1. Vision and Intent This bustling area caters to multiple functions, including retail, entertainment, civic, cultural, and residential uses. New buildings are organized along the civic plaza called "Bell Tower Walk" and are oriented perpendicular to the river so as not to inhibit views to the river from the bluff. The Bell Tower Walk is the center of a lively area on the Knoxville South Waterfront where outdoor restaurants, fairs and musical events attract local Knoxvillians and regional visitors both day and night and year round. Bell Tower Walk creates a "window-to-the-water" from the Baptist Church on Sevier Avenue leading down to the riverfront. It will serve as the central celebratory space for the community and could be used in conjunction with marketplace piers for small-scale festivals and urban markets throughout the year. Low to mid-rise, mixed-use or multiple unit housing developments face this linear open space and are encouraged to have commercial development on the first floor. To the west of this civic plaza, a cultural center and museum overlooks an outdoor amphitheater and marina that connect to the river walk. Parking structures are housed beneath the buildings or behind them to accommodate the area's many visitors and employees.  2. Existing Conditions and Block Layout a. Intent Guide site survey to assess existing site conditions for constraints and opportunities. Allow some views to river and downtown from taller buildings, when viewed from neighborhoods behind. b. Topography Consider existing topography and provide topographic survey with 2-foot contours. c. Existing Trees i. Identify all existing trees with a 6-inch minimum caliper including root zone within dripline. ii. Preserve a minimum of 1 healthy large canopy tree per lot, or 6 healthy trees per acre, whichever is greater. d. Environmental and Archaeological Comply with State and Federal Requirements. 3. Block Layout a. Intent Guide lot layout and outline the maximum block perimeter and building setbacks permitted in this district to ensure walkable neighborhoods. b. Block Size Maximum perimeter of 1,400 feet. c. Building Lines Minimum of 70 feet from normal pool EL 813.0. Refer to Sec. 7.1.6, Riverscape Standards. d. Proposed Subdivision and Phasing Plan Clearly designate future phases and describe proposed subdivision plan and phasing when applicable. 4. Building Siting and Configuration Intent: Provide building configuration and design parameters, as well as suggestions for building function.  Principal Building Siting | Orientation | NA Front Setback | 0' Frontage at Setback (min) | 75% to River Rd. and Sevier Ave. Side Setback (max) | 25' Rear Setback (min) | 3' Lot Size (max) | 3 acres Building Coverage (max) | 90% Open Space Coverage (min) | 10% Principal Building Configuration | Building Width | NA Building Height (min) | 40' & 3 Story Building Height (max) | 80' & 7 Stories plus 20' and 2 Story max at Setback + 10' Footprint/Floor Plate (max) | 30,000 SF; Does not apply to structured parking footprint Floor Area Ratio (max) | 7 5. Ancillary Structures and Outdoor Spaces a. Intent Provide outdoor space configuration and design parameters. b. Ancillary/Accessory Structures NA c. Ancillary/Accessory Structure Envelope i. Footprint/Floor Plate: NA ii. Front Setback: NA iii. Frontage at Setback: NA iv. Side Setback: NA. v. Rear Setback: NA vi. Building Width: NA vii. Building Height: NA d. Outdoor Space Types Courtyards, plazas, mall e. Usable Private Open Space NA 6. Building Frontages Frontage Typologies: Refer to Sec. 7.1.4.C.  Building Frontages | A building that includes an arcade facing a civic open space may build this arcade within the public R. O. W. | Building Entries | Primary entry on principal frontage | Building Envelope Articulation | Ground Level | Min 70% transparent glass at the ground level on the principal frontage Façade Length | NA Façade Openings | Openings above the first story on the principal frontage shall be min 25% of the building wall area Roofs | Buildings may have flat or sloped roofs Other | Balconies, porches, bay windows and other projections are encouraged and may be incorporated into the building setback 7. Off Street Parking and Loading Intent: Provide with adequate parking to accommodate the district's various building types and functions. Refer to Sec. 7.1.4.D.  a. Parking Types Surface lot, above ground structure, basement garage. b. Parking Spaces, Reserved and Shared Maximum of 3 parking spaces per 1,000 square feet and maximum of 2 parking spaces per residential unit. c. Pavements 65% minimum of uncovered surface parking shall be permeable while meeting overall stormwater requirements. d. Garage Location To rear or center of property or underneath building. e. Screening and Shading One tree (with a 2-inch minimum caliper) is required for every 5 surface parking spaces. f. Accessible Spaces and Routes Meet or exceed city accessibility standards. g. Driveways i. Driveway shall be 15-foot maximum for one way traffic and 26-foot maximum for two way traffic. ii. Sidewalk materials and patterning is continuous through driveway. h. Garage Entry Permitted on all frontages. i. Service Loading Permitted. j. Bicycle Parking Required. 8. External Elements Intent: Guide the integration of external elements into property development including landscaping, utilities and lighting. Refer to Sec. 7.1.4.E, Signage and Sec. 7.1.4.F, Lighting and Noise.  a. Proposed Topography Grades Provide grading plan with 2-foot contours. b. Side or Rear Privacy Fence or Wall Maximum of 8 feet. c. Front Fence or Wall Maximum of 3 feet and 6 inches. d. Landscape Vegetation i. Minimum of 8 trees (with a 2-inch minimum caliper) per acre of open space. ii. Trees required for surface parking may be counted toward overall landscape requirement. e. Trash/Recycling Storage, External Mechanical Units, Electrical Units and Rain Barrels Integrate with building design or screen/conceal from view from public street and riverwalk. 9. Sustainability a. Intent Encourage longevity, durability, energy and economic efficiency as well as improved environmental conditions. b. Green Building and Landscape i. Capable of attaining the current Leadership in Energy and Environmental Design (LEED) minimal Performance Level of "Certified." ii. Submit completed worksheet of appropriate LEED standard to demonstrate pre-certification estimate. c. Reflectivity, Heat Island Reduction, Roof and Surface Lots i. Surface lots shall provide shade and/or use light-colored/high albedo materials with a solar reflectance of at least 0.3 (30%). ii. Roofs shall use an Energy Star Compliant (highly reflective) for a minimum of 75% of the roof surface. G. SW6 Henley Gateway  1. Vision and Intent The Henley Gateway establishes a new entrance into downtown Knoxville, as well as a Chapman Highway gateway leading south to the Smoky Mountains. Capitalizing on the presence and economic opportunities of the Baptist Hospital, this area shall host multi-story office buildings, attracting new businesses to South Knoxville. A high-rise hotel with sweeping river views could accommodate business professionals as well as a multitude of city visitors. The dominant open green space in the shape of a triangular wedge is organized according to the proposed development as well as towards Chapman Highway. The park space provides views to the river and downtown and contains a parking garage underneath. New mid-rise towers facing the park are envisioned as a compliment to the surrounding institutional uses and to the scale of the Baptist Hospital. Landscaped plazas not only provide professionals with pleasant lunchtime spaces, but also establish a pedestrian-friendly connection from City View to Bell Tower Walk and Waterfront Marketplace. A setback from the river allows for existing and new development to access a continuous Shoals Promenade Riverwalk. A potential conversion of the freight rail line to future light rail may provide public transportation to this district.  2. Existing Conditions a. Intent Guide site survey to assess existing site conditions for constraints and opportunities. Allow Some views to river and downtown from taller buildings. b. Topography Consider existing topography and provide topographic survey with 2-foot contours. c. Existing Trees i. Identify all existing trees with a 6-inch minimum caliper including root zone within dripline. ii. Preserve a minimum of 1 healthy large canopy tree per lot, or 6 healthy trees per acre, whichever is greater. d. Environmental and Archaeological Comply with State and Federal Requirements. 3. Block Layout a. Intent Guide lot layout and outline the maximum block perimeter and building setbacks permitted in this district to ensure walkable neighborhoods. b. Block Size Maximum perimeter of 1,400 feet. c. Building Lines Minimum of 70 feet from normal pool EL 813.0. Refer to Sec. 7.1.6, Riverscape Standards. d. Proposed Subdivision and Phasing Plan Clearly designate future phases and describe proposed subdivision plan and phasing when applicable. 4. Building Siting and Configuration Intent: Provide building configuration and design parameters, as well as suggestions for building function.  Principal Building Siting | Orientation | NA Front Setback | 0' Frontage at Setback (min) | 50% Side Setback (max) | 25' Rear Setback (min) | 3' Lot Size (max) | 3 acres Building Coverage (max) | 90% Open Space Coverage (min) | 10% Principal Building Configuration | Building Width | NA Building Height (min) | 40' & 3 Story Building Height (max) | 150' & 12 Stories plus 20' and 2 Story max at Setback + 10' Footprint/Floor Plate (max) | 50,000 SF; Does not apply to structured parking footprint Floor Area Ratio (max) | 11 5. Ancillary Structures and Outdoor Spaces a. Intent Provide outdoor space configuration and design parameters. b. Ancillary/Accessory Structures NA c. Ancillary/Accessory Structure Envelope i. Footprint/Floor Plate: NA ii. Front Setback: NA iii. Frontage at Setback: NA iv. Side Setback: NA v. Rear Setback: NA vi. Building Width: NA vii. Building Height: NA d. Outdoor Space Types Rooftop landscape e. Usable Private Open Space NA 6. Building Frontages Frontage Typologies: Refer to Sec. 7.1.4.C.  Building Entries | Primary entry on principal frontage | Building Envelope Articulation | Ground Level | Min 70% transparent glass at the ground level on the principal frontage Façade Length | NA Façade Openings | Openings above the first story on the principal frontage shall be min 25% of the building wall area Roofs | Buildings may have flat or sloped roofs Other | Balconies, porches, bay windows and other projections are encouraged and may be incorporated into the building setback 7. Off Street Parking and Loading Intent: Provide with adequate parking to accommodate the district's various building types and functions. Refer to Sec. 7.1.4.D.  a. Parking Types Surface lot, above ground structure, basement garage. b. Parking Spaces, Reserved and Shared Maximum of 3 parking spaces per 1,000 square feet and maximum of 2 parking spaces per residential unit. c. Pavements 65% minimum of uncovered surface parking shall be permeable while meeting overall stormwater requirements. d. Garage Location To rear or center of property or underneath building. e. Screening and Shading One tree (with a 2-inch minimum caliper) is required for every 5 surface parking spaces. f. Accessible Spaces and Routes Meet or exceed city accessibility standards. g. Driveways i. Driveway shall be 15-foot maximum for one way traffic and 26-foot maximum for two way traffic. ii. Sidewalk materials and patterning is continuous through driveway. h. Garage Entry Permitted on all frontages. i. Service Loading Permitted. j. Bicycle Parking Required. 8. External Elements Intent: Guide the integration of external elements into property development including landscaping, utilities and lighting. Refer to Sec. 7.1.4.E, Signage and Sec. 7.1.4.F, Lighting and Noise.  a. Proposed Topography Grades Provide grading plan with 2-foot contours. b. Side or Rear Privacy Fence or Wall Maximum of 8 feet. c. Front Fence or Wall Maximum of 3 feet 6 inches. d. Landscape Vegetation i. Minimum of 8 trees (with a 2-inch minimum caliper) per acre of open space ii. Trees required for surface parking may be counted toward overall landscape requirement. e. Trash/Recycling Storage, External Mechanical Units, Electrical Units and Rain Barrels Integrate with building design or screen/conceal from view from public street and riverwalk. 9. Sustainability a. Intent Encourage longevity, durability, energy and economic efficiency as well as improved environmental conditions. b. Green Building and Landscape i. Capable of attaining the current Leadership in Energy and Environmental Design (LEED) minimal Performance Level of "Certified." ii. Submit completed worksheet of appropriate LEED standard to demonstrate pre-certification estimate. c. Reflectivity, Heat Island Reduction, Roof and Surface Lots i. Surface lots shall provide shade and/or use light-colored/high albedo materials with a solar reflectance of at least 0.3 (30%). ii. Roofs shall use an Energy Star Compliant (highly reflective) for a minimum of 75% of the roof surface. H. SW7 Waterfront Marketplace  1. Vision and Intent This area is an extension of the Bell Tower Walk. It is envisioned as a highly active commercial, entertainment, and residential environment. Bound between a newly established Waterfront Drive and the riverfront setback, the new Waterfront Piers provide an elegant setting for restaurants and various retail and entertainment enterprises. These uses define associated civic plazas that unite the buildings with the Riverwalk and the Gay Street Amphitheater. Developments on this site shall maximize view corridors to the river by orienting long, horizontal buildings perpendicular to the riverfront. Developments that create a continuous visual barrier to the Tennessee River are not permitted. Surface parking in this district shall be kept to a minimum. A new marina and boat ramp at the base of the Gay Street Bridge invite users to spend time on the water adjacent to the park space.  2. Existing Conditions a. Intent Guide site survey to assess existing site conditions for constraints and opportunities. Direct views to river and downtown, viewed from neighborhoods behind. b. Topography Consider existing topography and provide topographic survey with 2-foot contours. c. Existing Trees i. Identify all existing trees with a 6-inch minimum caliper including root zone within dripline. ii. Preserve a minimum of 1 healthy large canopy tree per lot, or 6 healthy trees per acre, whichever is greater. d. Environmental and Archaeological Comply with State and Federal Requirements. 3. Block Layout a. Intent Guide lot layout and outline the maximum block perimeter and building setbacks permitted in this district to ensure walkable neighborhoods. b. Block Size Maximum perimeter of 1,400 feet. c. Building Lines Minimum of 70 feet from normal pool EL 813.0. Refer to Sec. 7.1.6, Riverscape Standards. d. Proposed Subdivision and Phasing Plan Clearly designate future phases and describe proposed subdivision plan and phasing when applicable. 4. Building Siting and Configuration Intent: Provide building configuration and design parameters, as well as suggestions for building function.  Principal Building Siting | Orientation | Perpendicular to River Front Setback | NA Frontage at Setback | NA Side Setback (min) | 25' Rear Setback | NA Lot Size (max) | 1 acre Building Coverage | NA Open Space Coverage (min) | 20% Principal Building Configuration | Building Width (max) | 70' Building Height (min) | 25' & 2 Story Building Height (max) | 50' & 4 Stories plus 10' and 1 Story max at Setback + 10' Footprint/Floor Plate (max) | 30,000 SF; Does not apply to structured parking footprint Floor Area Ratio (max) | 3 5. Ancillary Structures and Outdoor Spaces a. Intent Provide outdoor space configuration and design parameters. b. Ancillary/Accessory Structures NA c. Ancillary/Accessory Structure Envelope i. Footprint/Floor Plate: NA ii. Front Setback: NA iii. Frontage at Setback: NA iv. Side Setback: NA v. Rear Setback: NA vi. Building Width: NA vii. Building Height: NA d. Outdoor Space Types Mall, Plaza e. Usable Private Open Space NA 6. Building Frontages Frontage Typologies: Refer to Sec. 7.1.4.C.  Building Entries | Primary entry on principal frontage | Building Envelope Articulation | Ground Level | Min 70% transparent glass at the ground level on the principal frontage Façade Length | NA Façade Openings | Openings above the first story on the principal frontage shall be min 25% of the building wall area Roofs | Buildings may have flat or sloped roofs Other | Balconies, porches, bay windows and other projections are encouraged and may be incorporated into the building setback 7. Off Street Parking and Loading Intent: Provide with adequate parking to accommodate the district's various building types and functions and maintain the overall neighborhood character. Refer to Sec. 7.1.4.D.  a. Parking Types Surface lot, above ground structure, basement garage. b. Parking Spaces, Reserved and Shared Maximum of 3 parking spaces per 1,000 square feet and maximum of 2 parking spaces per residential unit. c. Pavements 65% minimum of uncovered surface parking shall be permeable while meeting overall stormwater requirements. d. Garage Location To side of property or underneath building. e. Screening and Shading One tree (with a 2-inch minimum caliper) is required for every 5 surface parking spaces. f. Accessible Spaces and Routes Meet or exceed city accessibility standards. g. Driveways i. Driveway shall be 15-foot maximum for one way traffic and 26-foot maximum for two way traffic. ii. Sidewalk materials and patterning is continuous through driveway. h. Garage Entry Permitted on all frontages. i. Service Loading Permitted. j. Bicycle Parking Required. 8. External Elements Intent: Guide the integration of external elements into property development including landscaping, utilities and lighting. Refer to Sec. 7.1.4.E, Signage and Sec. 7.1.4.F, Lighting and Noise.  a. Proposed Topography Grades Provide grading plan with 2-foot contours. b. Side or Rear Privacy Fence or Wall Maximum of 8 feet. c. Front Fence or Wall Maximum of 3 feet 6 inches. d. Landscape Vegetation i. Minimum of 8 trees (with a 2-inch minimum caliper) per acre of open space. ii. Trees required for surface parking may be counted toward overall landscape requirement. e. Trash/Recycling Storage, External Mechanical Units, Electrical Units and Rain Barrels Integrate with building design or screen/conceal from view from public street and riverwalk. 9. Sustainability a. Intent Encourage longevity, durability, energy and economic efficiency as well as improved environmental conditions. b. Green Building and Landscape i. Capable of attaining the current Leadership in Energy and Environmental Design (LEED) minimal Performance Level of "Certified." ii. Submit completed worksheet of appropriate LEED standard to demonstrate pre-certification estimate. c. Reflectivity, Heat Island Reduction, Roof and Surface Lots i. Surface lots shall provide shade and/or use light-colored/high albedo materials with a solar reflectance of at least 0.3 (30%). ii. Roofs shall use an Energy Star Compliant (highly reflective) for a minimum of 75% of the roof surface.
Ask a question about Knoxville law
Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.