§ 7.2.4 — BUILDING ELEMENTS
Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Zoning Code, art. 7, § 7.2.4
Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/a456619b-2611-487c-b4c6-05302224460c
7.2.4. - BUILDING ELEMENTS
Building elements are allowed by district as forth in Sec. 7.2.3. The following standards apply to allowed building elements.  A. Porch A raised structure attached to a building, forming a covered entrance to a doorway. 1. A front porch must be at least 6 feet deep (not including the steps). 2. A front porch must be contiguous, with a width not less than 33% of the building façade from which it projects. 3. A front porch must be roofed but cannot be fully enclosed. 4. A front porch may extend up to 9 feet, including the steps, into a required setback, provided that such extension is at least 2 feet from the vertical plane of any lot line. 5. A front porch may not encroach into the public right-of-way.  B. Stoop A small raised platform that serves as an entrance to a building. 1. A stoop may be no more than 6 feet deep (not including the steps) and 6 feet wide. 2. A stoop may be covered but cannot be fully enclosed. 3. A stoop may extend a up to 6 feet into a required setback, provided that the landing is at least 2 feet from the vertical plane of any lot line. 4. A stoop may not encroach into the public right-of-way.  C. Balcony A platform projecting from the wall of a building with a railing along its outer edge, often with access from a door or window. 1. A balcony must be at least 4 feet deep and may extend up to 6 feet into a required setback, provided that such extension is at least 2 feet from the vertical plane of any lot line 2. A balcony must have a clear height above the sidewalk of at least 10 feet. 3. A balcony may be covered but cannot be fully enclosed. 4. A balcony may not encroach into the public right-of-way without a "Use Agreement" for the use of public right-of-way. 5. No balcony encroachments are allowed on Cumberland Avenue.  D. Gallery A covered passage extending along the outside wall of a building supported by arches or columns that is open on 3 sides. 1. A gallery must have a clear depth from the support columns to the building's façade of at least 8 feet and a clear height above the sidewalk of at least 10 feet. 2. A gallery must be contiguous and extend over at least 50% of the width of the building façade from which it projects. 3. A gallery may extend into a required setback. 4. A galley may not encroach into the public right-of-way without a license for the use of public right-of-way.  E. Awning/Canopy A wall-mounted, cantilevered structure providing shade and cover from the weather for a sidewalk. 1. An awning/canopy must be a minimum of 10 feet clear height above the sidewalk and must have a minimum depth of 6 feet. 2. An awning/canopy may extend into a required setback. 3. An awning/canopy may not encroach into the public right-of-way without a license for the use of public right-of-way.  F. Forecourt An open area at grade, or within an average 30 inches of grade, that serves as an open space or plaza. 1. A forecourt must be no more than 1/3 of the length of the building face, and in no case longer than 35 feet in width. 2. A forecourt may be no more than 35 feet in depth. 3. A maximum of one forecourt is permitted per site. 4. A forecourt is considered as part of the building for the purpose of measuring the build-to zone.
Ask a question about Knoxville law
Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.
