§ 6.2.4 — Gas Well Development Site Plans
Code of Ordinances, City of Denton, Texas (Supp. No. 37, Update 1: codified through Ordinance No. 26-296 adopted March 24, 2026) · Denton Development Code subch. 6, § 6.2.4
Corpus is an independent public-information project, not the official City of Denton website. Stable reference: corpuslaw.us/code/eb506082-7fc3-4840-80ae-61beb41e025d
6.2.4 - Gas Well Development Site Plans.
A. Gas Well Development Site Plan. 1. Applicability. a. A Gas Well Development Site Plan approved under this amendatory ordinance is required to authorize multiple gas wells on a Drilling and Production Site and must be approved prior to issuance of any Gas Well Permit for any new well on the site. b. Notwithstanding subsection A, new wells identified on an approved Existing Gas Well Development Site Plan may be permitted in accordance with the gas well ordinance regulations in effect immediately prior to the effective date of this amendatory ordinance. c. A gas well development plat is not an Existing Gas Well Development Site Plan. d. A Gas Well Development Site Plan is not required to authorize Workover Operations, Drilling Activities or Production Activities for an existing gas well for which a gas well permit was issued prior to the effective date of this amendatory ordinance. 2. Application Requirements. a. A cover page that includes a vicinity map of the Drilling and Production Site; a Sheet Index that identifies the number of Exhibits with titles for each (exhibit titles shall begin with the word 'Exhibit' and include the respective letter); the Project Title; the date of preparation; the preparer, Operator, and property owner's names; space for the City project number; and a signature block for both the Gas Well Administrator and the City Secretary. b. A mapping exhibit with an accurate legal description of the Drilling and Production Site that was prepared and certified by a Registered Professional Land Surveyor of the State of Texas. Provide closure sheet of bearings and distances used in legal description. The exhibit shall include exact location, dimension, and description of all existing public, proposed, or private easements, and public rights-of-way within the lease area, intersecting or contiguous with its boundary, or forming such boundary. Describe and locate all permanent survey monuments, pins, and control points and tie and reference the survey corners to the Texas State Plane Coordinate System North Central Zone 1983-1999 datum. Provide proposed pipeline route—note that a separate application may be necessary if the proposed route encroaches onto any public easement, right-of-way or land owned by the City of Denton. c. The maximum size of a proposed Drilling and Production Site shall be three acres, unless the Operator can demonstrate to the City at the time of filing of a Gas Well Development Site Plan application that: (i) the surface owner(s) has agreed to a larger site via a written agreement that will be recorded by the Operator in the Denton County records, (ii) the surface owner is subject to a covenant in a written instrument, or memorandum thereof, recorded prior to August 4, 2015, that authorizes a larger site, or (iii) the Operator can demonstrate that a larger site is needed to accommodate the planned gas well operations based upon the acreage that the Operator presently has under the mineral lease; provided that no new Drilling and Production Site authorized under (i), (ii) or (iii) may exceed seven acres, unless authorized by the Board of Adjustment. For a Gas Well existing on the effective date of this amendatory ordinance, evidence that the current Drilling and Production Site is greater than the maximum size shall be sufficient proof to demonstrate that a larger site is needed to accommodate the planned gas well operations proposed by the Gas Well Development Site Plan. A gas well development plat is neither a written agreement nor a written instrument or memorandum within the meaning of this subsection. d. A map showing the distance from the boundaries of the Drilling and Production Site from all Protected Uses and Residential Subdivisions. If the separation distance(s) from Protected Uses and Residential Subdivisions do not meet the setback requirements of Subsection 6.2.2, the application also must include a copy of the waivers approved pursuant to Subsection 6.2.6A, or the approval of a setback variance approved by the Board of Adjustment pursuant to Subsection 6.2.6B. If the Operator seeks to qualify the proposed Drilling and Production Site for an administrative waiver pursuant to Subsection 6.2.6C, the information therein required shall be submitted with the application for site plan approval. e. A site plan of the Drilling and Production Site, capable of being recorded, showing clear site boundary lines and the location of all on-site improvements and equipment, including: tanks, pipelines, compressors, separators, and other appurtenances in relation to the boundaries of the site. f. A legal description of the proposed Drilling and Production Site. g. An Erosion and Sediment Control Plan. Such exhibit must include contact information, a physical site description including: land uses; general vegetation and surface water in near proximity; topography/contour lines both pre- and post-construction; hydrologic analysis including: stormwater directional flow, outfalls, water well related structures and water sources; receiving waters; soils; project narrative with general timeline; well pad site plan including: fueling areas, waste disposal containers, hazardous materials storage, and product and condensate storage tanks, soil stabilization and erosion control measures including: list of selected stormwater measures, site map of selected stormwater measures, locations and final stabilization plans; solid waste management plan, septic/portolet location; and maintenance plan for stormwater controls including schedule and transfer of ownership provision. See Gas Well Erosion and Sediment Control Plan Guidance Document for details. h. An Access and Transportation Plan identifying the points of access and routes to be followed on the road network supporting gas well development on the Drilling and Production Site over time, and the internal circulation plan for the property containing the proposed site, including provisions to protect vehicle access to Neighborhood Streets. The Plan shall contain specifications for construction of the access road(s) and on-site fire lanes that meet the standards for emergency access set forth in paragraph 6.3.2E. A map showing transportation route and road for equipment, supplies, chemicals, or waste products used or produced by the gas well operation shall be included. The map shall illustrate the length of all public roads that will be used for site ingress and egress. The water source proposed for both the drilling and fracturing stages shall be identified in the Plan, together with a designation whether the water is to be hauled or piped to the site. i. A Landscape Plan. The project review planner will determine if a buffer is required based on the adjacent land use(s). If the planner determines a buffer is required, then a landscape plan must be submitted in accordance with the City of Denton's Landscape Plan Checklist. Not every Drilling and Production Site requires a landscape plan. j. A Tree Inventory and Preservation and Mitigation Plan. For sites with trees, a Tree Inventory and a Preservation Plan and Mitigation Plan pursuant to DDC, Subsection 7.7.4: Tree Preservation will be submitted. k. A copy of any prior approvals required, including conditions imposed, such as a specific use permit (SUP) or watershed protection permit; l. A Noise Management Plan, prepared in accordance with paragraph 6.3.2F.2; and m. Proof of issuance of Notice of Activities pursuant to paragraph 6.3.7A.1. 3. Procedures and Criteria. a. Processing of Application. An application for a Gas Well Development Site Plan shall be processed in accordance with the requirements of Subsection 2.6.6: Gas Well Development Plat, and shall be decided by the Gas Well Administrator. b. Criteria. The Gas Well Administrator shall approve the application if it meets the following standards: i. The site meets the setback requirements of Subsection 6.2.2, a waiver has been granted or a variance from such standards has been approved by the Board of Adjustment or the Gas Well Administrator. ii. The application is consistent with any applicable SUP, MPC or PD site specific authorization, or Watershed Protection Permit and any conditions incorporated therein. iii. The application meets applicable requirements of Subsection 6.3.2. iv. The size of the Drilling and Production Site can accommodate the number of wells proposed. v. The site is adequately served by a road network, does not take access from any Neighborhood Street, and road remediation fees have been paid. vi. Notice of the application has been posted pursuant to Subsection 6.3.7. c. Conditions. The Gas Well Administrator may impose conditions that assure compliance with the terms of the prior approvals or standards of this Subchapter. 4. Effect. The approval of a Gas Well Development Site Plan authorizes the Operator to apply for a Gas Well Permit for each well authorized by the Site Plan and other permits required before commencement of Drilling Activities on the Drilling and Production Site. 5. Recordation. An approved Gas Well Development Site Plan must be recorded by the Operator in the Denton County Records prior to the issuance of a Gas Well Permit. B. Amended Gas Well Site Plan. 1. If the Operator proposes to do any of the following, an Amended Gas Well Development Site Plan shall be required. The applications shall be reviewed and decided in the same manner as the original application. a. Relocate the boundaries of the Drilling and Production Site. b. Expand the boundaries of the Drilling and Production Site. c. Change the layout of the structures or appurtenances within the boundaries of the approved Drilling and Production Site. d. Change the access road(s) or the location of the access road(s). 2. The application shall be reviewed and decided in the same manner as the original application for the Drilling and Production Site. 3. The setback requirements of Subsection 6.2.2 shall apply to activities described in paragraphs 6.2.4B.1.a and 6.2.4B.1.b above. 4. An approved Amended Gas Well Development Site Plan shall be recorded as required by paragraph 6.2.4A.5 above. C. Expiration and Extension of Gas Well Development Site Plans. 1. A Gas Well Development Site Plan for a new Drilling and Production Site expires unless a complete application for a Gas Well Permit has been filed within one year of the date of approval of the Site Plan, or no drilling and production activities have occurred on the Site for a period of three years. 2. A Gas Well Development Site Plan for an Existing Site does not expire, unless no drilling and production activities have occurred on the site for a period of two years after all wells on the site have been plugged and abandoned. 3. An Operator may seek a special exception from the Board of Adjustment pursuant to paragraph 6.2.6B for a one-year extension of the expiration date for a Gas Well Development Site Plan for a new Drilling and Production Site.
Ask a question about Denton law
Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.