§ 15.75.050 — Definitions
Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 15.75.050
Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/62129200-dfe0-43af-94d3-9a2ed2174183
15.75.050 Definitions.
The following definitions shall apply for the purposes of this chapter: (a) “Apartment house” is a building or portion thereof containing three or more units and does not include condominiums as defined in Title 18. (b) “Aspect ratio” is the ratio of the height of a wall section to its width. Wall height is measured from sill plate to top of double top plate. (c) “Building Code” is the latest edition of the California Building Code, as adopted and modified in Division 1 of this title. (d) “Cripple wall” is a wood-framed stud wall extending from the top of the foundation wall to the underside of the lowest floor framing, and not enclosing a parking or otherwise habitable area. (e) Concrete Anchors. (1) “Expansion anchor” is an approved mechanical fastener placed in hardened concrete, designed to expand in a self-drilled or predrilled hole of a specified size and engage the sides of the hole in one or more locations to develop shear and tension resistance to applied loads without grout, adhesive or drypack. (2) “Chemical anchor” is an approved metal fastener and structural epoxy anchoring device in hardened concrete or solid masonry. It is designed to adhere to the sides of a predrilled hole of specified size to develop shear and tension resistance to applied loads. (3) “Undercut anchor” is an approved mechanical fastener placed in hardened concrete, designed to expand into an undercut specially predrilled hole of specified size. The anchor engages the sides and undercut surfaces of the hole in one or more locations to develop high shear and tension resistance to applied loads without grout, adhesive or drypack. (f) “Floor diaphragm aspect ratio” is the ratio of the diaphragm depth to its width (diaphragm depth measured perpendicular to the open front). (g) “Ground floor” is any floor within the wood-frame portion of a building whose elevation is immediately accessible from an adjacent grade by vehicles or pedestrians. The ground floor portion of the structure does not include any level that is completely below adjacent grades. (h) “Level” is a story, basement, or underfloor space of a building with cripple walls exceeding four feet in height. (i) “Multi-unit residential buildings” are hotels, lodging houses, congregate residences, apartment houses, and condominiums. (j) “Nonconforming structural materials” are wall bracing materials which are no longer permitted by this code. These methods or materials include, but are not limited to, cement or gypsum plaster, gypsum wallboard, diagonal or let-in bracing, straight or diagonal wood sheathing, particle board and structural wood panels. (k) “Open front wall line” is an exterior wall line without vertical elements of the lateral force resisting system which requires tributary seismic forces to be resisted by diaphragm rotation or excessive cantilever beyond parallel lines of shear walls. Diaphragms that cantilever more than 25 percent of the distance between adjacent lines of lateral force resisting elements shall be considered excessive. Exterior exit balconies shall not be considered as excessive cantilevers. (l) “Retrofit” is an improvement of the lateral force resisting system by alteration of existing structural elements or addition of new structural elements. (m) “Second floor” is the first elevated floor level. (n) “Soft wall line” is a wall line whose lateral stiffness is less than required by the story drift limitations or deformation compatibility requirements of this chapter. In lieu of analysis, this may be defined as a wall line in a story where the story stiffness is less than 70 percent of the story above for the direction under consideration. (o) “Story strength” is the total strength of all compatible seismic resisting elements sharing the story shear in the direction under consideration. (p) “Wall diaphragm aspect ratio” is the ratio of the height of a wall section to its width. (q) “Wall line” is any length of a wall along a principal axis of the building used to provide resistance to lateral loads. Parallel wall lines separated by less than four feet shall be considered one wall line for the distribution of loads. (r) “Weak wall line” is a wall line in a story where the story strength is less than 80 percent of the story above in the direction under consideration. (Ord. 10-2007 § 7, 5-1-07. 1990 Code § 7-10104.)
Ask a question about Fremont law
Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.