15.75.140 Performance standards.

(a) Buildings within the scope of this chapter shall be analyzed, designed and constructed in conformance with the Building Code, except as modified by this chapter, and shall conform to Sections 15.75.150 and 15.75.170. EXCEPTION: The seismic retrofit of buildings that meet the limitations and additional conditions for prescriptive measures under Section 15.75.160 may be constructed according to those prescriptive measures without complying with Section 15.75.150. (b) No alteration of the existing force-resisting or vertical load-carrying system shall reduce the strength or stiffness of the existing structure. (c) When any portion of a building within the scope of this chapter is constructed on or into a slope steeper than one unit vertical in three units horizontal, the lateral-force-resisting system at and below the base level diaphragm shall be analyzed for the effects of concentrated lateral forces at the base due to this hillside condition. (Ord. 10-2007 § 19, 5-1-07. 1990 Code § 7-10301.)