15.75.170 Materials of construction.
(a) New Materials. All materials approved by the Building Code, including their appropriate allowable stresses and minimum aspect ratios, shall be permitted to meet the requirements of this chapter. (b) Allowable Foundation and Lateral Pressures. The use of default values from the Building Code for continuous and isolated concrete spread footings shall be permitted. For soil that supports embedded vertical elements, Section 15.75.150(e) shall apply. (c) Existing Materials. All existing materials shall be in sound condition and constructed in conformance to the Building Code before they can be used to resist the lateral loads prescribed in this chapter. The verification of existing material conditions and their conformance to these requirements shall be made by physical observation reports, material testing or record drawings as determined by the structural designer and approved by the building official. (1) Horizontal Wood Diaphragms. Allowable shear values for existing horizontal wood diaphragms that require analysis under Section 15.75.150 may be taken from the following table. The values in the table shall be used for allowable stress design. Design forces based on strength design shall be reduced to allowable stress levels before comparison with the limiting values in the table. | EXISTING MATERIALS OR CONFIGURATIONS OF MATERIALS | ALLOWABLE VALUES x 14.594 FOR N/m | 1. Horizontal diaphragms. | 1.1. Roofs with straight sheathing and roofing applied directly to the sheathing | -100 lbs. per ft. for seismic shear | 1.2. Roofs with diagonal sheathing and roofing applied directly to the sheathing | 250 lbs. per ft. for seismic shear | 1.3. Floors with straight tongue-and-groove sheathing | 100 lbs. per ft. for seismic shear | 1.4. Floors with straight sheathing and finished wood flooring with board edges offset or perpendicular | 500 lbs. per ft. for seismic shear | 1.5. Floors with diagonal sheathing and finished wood flooring | 600 lbs. per ft. for seismic shear | 2. Crosswalls | Per side: | 2.1. Plaster on wood or metal lath | 200 lbs. per ft. for seismic shear | 2.2. Plaster on gypsum lath | 175 lbs. per ft. for seismic shear | 2.3. Gypsum wallboard, unblocked edges | 75 lbs. per ft. for seismic shear | 2.4. Gypsum wallboard, blocked edges | 125 lbs. per ft. for seismic shear | 3. Existing footings, wood framing, structural steel and reinforced steel | 3.1. Plain concrete footings | f: = 1,500 psi (10.3 MPa) unless otherwise shown by tests | 3.2. Douglas fir wood | Allowable stress same as D.E. No. Id | 3.3. Reinforcing steel | Fs = 18,000 psi (124 MPa) | 3.4. Structural steel | maximum Fs = 20,000 psi (138 MPa) maximum (2) Wood Structural-Panel Shear Walls. (A) Allowable Nail Slip Values. The use of box nails and unseasoned lumber are permitted to be assumed. When the required drift calculations of Section 15.75.150(k)(2)(A) (drift limit for wood-framed shear walls) rely on the slip values for common nails or surfaced dry lumber, their use in construction shall be verified by exposure. The design value of the box nails shall be assumed to be similar to that of common nails having the same diameter. Verification of surfaced dry lumber shall be by identification conforming to the Building Code. (B) Plywood Panel Construction. When verification of the existing plywood materials is by use of record drawings alone, the panel construction for plywood modulus “G” shall be assumed equal to 50,000 pounds per square inch (345 megapascals). (3) Existing Wood Framing. Wood framing is permitted to use the design stresses specified in the building code under which the building was constructed or other stress criteria approved by the building official. (4) Structural Steel. All existing structural steel shall be permitted to use the allowable stresses for Grade A36. Existing pipe or tube columns shall be assumed to be of minimum wall thickness unless verified by testing or exposure. (5) Strength of Concrete. All existing concrete footings shall be permitted to be assumed to be plain concrete with compressive strength of 2,000 pounds per square inch (13.8 megapascals). Existing concrete compressive strength taken greater than 2,000 pounds per square inch (13.8 megapascals) shall be verified by testing, record drawings or department records. (6) Existing Sill Plate Anchorage. Existing cast-in-place anchor bolts shall be permitted to use the allowable service loads for bolts with proper embedment when used for shear resistance to lateral loads. (Ord. 10-2007 § 22, 5-1-07. 1990 Code § 7-10304.)
For SI: 1 foot = 304.8 mm. | a. Material must be sound and in good condition. | b. A one-third increase in allowable stress is not allowed. | c. Shear values of these materials may be combined, except the total combined value shall not exceed 300 pounds per foot. | d. Stresses given may be increased for combination of loads as specified in the Building Code.
Ask a question about Fremont law
Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.