§ 15.75.150 — Analysis and retrofit

Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 15.75.150

Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/21cdb74d-1e12-4a9e-86d3-673eeff6a020

15.75.150 Analysis and retrofit.

(a) Scope of Analysis. This chapter requires the alteration, repair, replacement or addition of structural elements and their connections to meet the strength and stiffness requirements herein. The lateral load path analysis shall include the resisting elements and connections from the wood diaphragm above any soft, weak or open front wall lines to the foundation soil interface or the upper level of a rigid substructure such as concrete subterranean or podium below. The top story of any building need not be analyzed. The lateral load path analysis for added structural elements shall also include evaluation of the allowable soil bearing and lateral pressures in accordance with the Building Code. EXCEPTION: When an open front, weak or soft wall line exists due to parking at the ground level of a two-level building and the parking area is less than 20 percent of the ground floor level, then only the wall lines in the open, weak or soft directions of the enclosed parking area need comply with the provisions of this chapter. (b) Design Base Shear. The design base shear in a given direction shall be 75 percent of the base shear required for similar new buildings as set forth in the Building Code. (c) Vertical Distribution of Forces. The total seismic force shall be distributed over the height of the structure based on the Building Code. (d) Weak Story Limitation. Weak story construction shall be strengthened to the lesser of: (1) Ω0 times the story shear prescribed by subsections (b) and (c) of this section. (2) In two-story buildings up to 30 feet in height, 65 percent of the strength of the story above. In all other buildings, 80 percent of the strength of the story above. (e) Story Drift Limitation. The calculated story drift for each retrofitted level shall not exceed the allowable deformation compatible with all vertical-load-resisting elements and be no more than 0.025 times the story height. The calculated story drift shall not be reduced by the effects of horizontal diaphragm stiffness but shall be increased when these effects produce rotation. The effects of rotation and soil stiffness shall be included in the calculated story drift when lateral loads are resisted by vertical elements whose required depth of embedment is determined by pole formulas such as Formula (6A-1) and (6A-2) in Building Code Section 1806.8.2. The coefficient of variation of subgrade reaction used in the deflection calculations shall be provided from an approved geotechnical engineering report or other approved methods. (f) P-Delta Effects. The requirements of the Building Code regarding P-delta effects shall apply except as modified herein. All structural framing elements and their connections, not required by design to be part of the lateral-force-resisting system, shall be designed and/or detailed to be adequate to maintain support of design dead plus live loads when subjected to the expected deformations caused by seismic forces. The stress analysis of cantilever columns shall use a buckling factor of 2.1 for the direction normal to the axis of the beam. (g) Ties and Continuity. All parts of the structure included in the scope of this section shall be interconnected and the connection shall be capable of resisting the seismic force created by the parts being connected. (h) Cripple Walls. Cripple walls braced with nonconforming structural materials shall be braced in accordance with this chapter. When a single top plate exists in the cripple wall, all end joints in the top plate shall be tied. (i) Collector Elements. Collector elements shall be provided which can transfer the seismic forces originating in other portions of the building to the elements within the scope of this section. (j) Horizontal Diaphragms. The strength of an existing horizontal diaphragm sheathed with wood structural panels or diagonal sheathing need not be investigated unless the diaphragm is required to transfer lateral forces from vertical elements of the seismic-force-resisting system above the diaphragm to elements below the diaphragm because offset in placement of the elements. Wood diaphragms with stories above shall not be allowed to transmit lateral forces by rotation or cantilever except as allowed by the Building Code; however, rotational effects shall be accounted for when unsymmetric wall stiffness increases shear demands. EXCEPTION: Diaphragms that cantilever 25 percent or less of the distance between lines of lateral-load-resisting elements from which the diaphragm cantilevers may transmit their shears by cantilever; provided, that rotational effects on shear walls parallel and perpendicular to the load are taken into account. (k) Wood-Framed Shear Walls. Wood-framed shear walls shall have strength and stiffness to resist the seismic loads and shall conform to the requirements of this section. (1) Gypsum or Plaster Products. Gypsum or cement plaster products shall not be used to provide lateral resistance in a soft or weak story or in a story with an open-front wall line, whether or not new elements are added to mitigate the soft, weak or open-front condition. (2) Wood Structural Panels. (A) Drift Limit. Wood structural panel shear walls shall meet the story drift limitation of this section. Conformance to the story drift limitation shall be determined by approved testing or calculation, not by the use of an aspect ratio. Calculated deflection shall be determined according to International Building Code Equation 23-1 and shall be increased by 25 percent. Contribution to the shear wall deflection from the anchor or tie-down slippage shall also be included. The slippage contribution shall include the vertical elongation of the metal components, the vertical slippage of the connectors to framing members, localized crushing of wood due to bearing loads and shrinkage of the wood elements because of changes in moisture content as a result of aging. The total vertical slippage shall be multiplied by the shear panel aspect ratio and added to the total horizontal deflection. Individual shear panels shall be permitted to exceed the maximum aspect ratio, provided the allowable story drift and allowable shear capacities are not exceeded. (B) Openings. Shear walls are permitted to be designed for continuity around openings in accordance with the building code. Blocking and steel strapping shall be provided at corners of the openings to transfer forces from discontinuous boundary elements into adjoining panel elements. Alternatively, perforated shear wall provisions of the building code are permitted to be used. (C) Wood Species of Framing Members. Allowable shear values for wood structural panels shall consider the species of the framing members. When the allowable shear values are based on Douglas fir-larch framing members, and framing members are constructed of other species of lumber, the allowable shear values shall be multiplied by the following factors: 0.82 for species with specific gravities greater than or equal to 0.42 but less than 0.49, and 0.65 for species with specific gravities less than 0.42. Redwood shall use a factor of 0.65 and hem fir shall use a factor of 0.82 unless otherwise approved. (3) Substitution for Three-Inch (76 Millimeter) Nominal Width Framing Members. Two two-inch (51 millimeter) nominal width framing members shall be permitted in lieu of any required three-inch (76 millimeter) nominal width framing member when the existing and new framing members are of equal dimensions, are connected as required to transfer the in-plane shear between them, and when the sheathing fasteners are equally divided between them. (4) Hold-Down Connectors. (A) Expansion Anchors in Tension. Expansion anchors that provide tension strength by friction resistance shall not be used to connect hold-down devices to existing concrete or masonry elements. Expansion anchors that provide tension strength by bearing (commonly referred to as “undercut” anchors) shall be permitted. (B) Required Depth of Embedment. The required depth of embedment or edge distance for the anchor used in the hold-down connector shall be provided in the concrete or masonry below any plain concrete slab unless satisfactory evidence is submitted to the building official that shows that the concrete slab and footings are of monolithic construction. (C) Required Preload of Bolted Hold-Down Connectors. Bolted hold-down connectors shall be preloaded to reduce slippage of the connector. Preloading shall consist of tightening the nut on the tension anchor after the placement but before the tightening of the shear bolts in the panel flange member. The tension anchor shall be tightened until the shear bolts are in firm contact with the edge of the hole nearest the direction of the tension anchor. Hold-down connectors with self-jigging bolt standoffs shall be installed in a manner to permit preloading. (Ord. 10-2007 § 20, 5-1-07. 1990 Code § 7-10302.)

Ask a question about Fremont law

Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.