§ 15.24.740 — NFPA 24, 2025 Edition

Murrieta Municipal Code (2026 S-23 through Ord. 639-26) · Murrieta Municipal Code § 15.24.740

Corpus is an independent public-information project, not the official City of Murrieta website. Stable reference: corpuslaw.us/code/0dd3c029-64d6-4657-8c78-1e7d9ffd1574

15.24.740 NFPA 24, 2025 Edition.

NFPA 24, 2025 Edition, Standard for the Installation of Private Fire Service Mains and their Appurtenances is hereby amended as follows: Section 6.2.9* (3) and (5) is hereby deleted without replacement and (6) and (7) renumbered as follows: (5) Control Valves installed in a fire-rated room accessible from the exterior. (6) Control valves in a fire-rated stair enclosure accessible from the exterior as permitted by the authority having jurisdiction. Section 6.2.9* (2) is hereby revised as follows: (2) When approved by the fire code official, a wall post indicating valve may be installed on an existing structure. Section 6.3.3 is hereby added as follows: 6.3.3 All post indicator valves controlling fire suppression water supplies shall be painted OSHA red. Section 10.1.5 is hereby added as follows: 10.1.5 All ferrous pipe shall be coated and wrapped. Joints shall be coated and wrapped after assembly. All fittings shall be protected with a loose 8-mil polyethylene tube. The ends of the tube shall extend past the joint by a minimum of 12 inches and be sealed with 2 inch wide tape approved for underground use. Galvanizing does not meet the requirements of this section. Exception: 304 or 316 Stainless Steel pipe and fittings Section 10.3.8 Bolts is hereby added as follows: 10.3.7 Bolts. All bolts used in pipe-joint assembly shall be 316 stainless steel. Section 10.4.1.1 is hereby revised as follows: 10.4.1.1 All bolted joint accessories shall be cleaned and thoroughly coated with asphalt or other corrosion-retarding material, prior to poly-tube, and after installation. Exception: Bolted joint accessories made from 304 or 316 stainless steel. Section 10.4.3.1 is hereby deleted and replaced as follows: 10.4.3.1 Where fire service mains enter the building adjacent to the foundation, the pipe may run under a building to a maximum of 24 inches, as measured from the interior face of the exterior wall to the center of the vertical pipe. The pipe under the building or building foundation shall be 304 or 316 stainless steel and shall not contain mechanical joints or it shall comply with 10.6.2. Section 10.4.3.1.1 is hereby revised as follows: 10.4.3.1.1 Pipe joints shall not be located under foundation footings. The pipe under the building or building foundation shall be 304 or 316 stainless steel and shall not contain mechanical joints. (Ord. 626-25 § 1 (part), 2025)

Ask a question about Murrieta law

Corpus searches the Murrieta sections it holds and shows the ones that match, with their citations. Free, no sign-in.