For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 21-237 — Large general electric service demand

Code of General Ordinances of the City of Tallahassee, Florida (Supp. No. 75: codified through Ordinance No. 25-O-28, enacted December 10, 2025) · Tallahassee City Code § 21-237

Corpus is an independent public-information project, not the official City of Tallahassee website. Stable reference: corpuslaw.us/code/78f97c30-4bd0-4c42-89f7-294d95766256

Sec. 21-237. - Large general electric service demand.

(a) Charges and collection. The city shall charge and collect for large general service demand electric energy on the basis of availability, application, character of service, monthly rate, minimum charge, determination of billing demand, power factor adjustment, primary service discount, transmission service discount, tax adjustment, and energy cost recovery. (b) Availability. The large general electric service demand schedule is available throughout the entire territory served by the city. (c) Application. The large general electric service demand schedule is applicable to all electric service required for lighting, power, and any other purpose with a maximum annual demand of 500 kW or more for three or more months out of 12 consecutive months ending with the September billing of each year. Upon request, this schedule may be made available to nonresidential customers with demands of 300 kW or greater who agree to pay for service under this schedule for 12 consecutive months. (d) Character of service. Service under the large general electric service demand schedule shall be single phase or three phase, 60-hertz, alternating current at standard available voltages. Where primary service of 12,470/7,200 volts is requested from the city's underground network system, such service will be provided only where the customer installs dual primary circuits complete with automatic load transfer equipment. Where more than one meter is utilized for this service, each shall be computed separately for billing purposes, unless installed by the city for reliability and/or capacity requirements. Standby or resale service is not permitted under this rate schedule. (e) Monthly rate. (1) Customer charge. Secondary service: $72.78 Primary service: $247.46 (2) Demand charge: $13.46 per kW billing demand per month. (3) Nonfuel energy charge. First 500 kWh per kW: $0.02237 Excess kWh per kW: $0.00324 (f) Adjustment. The amount computed at the monthly rate in this section shall be adjusted by an amount calculated in accordance with the formula specified in the city's energy cost recovery clause which is incorporated by reference as a part of this rate schedule. (g) Minimum charge. The monthly minimum charge shall be the customer charge plus the demand charge. (h) Determination of billing demand. The demand to be used for billing purposes shall be the maximum 30-minute integrated demand occurring during the month as indicated by a meter installed to measure demand adjusted for power factor if applicable. (i) Power factor adjustment. Bills computed under the rate per month charges in this section will be increased $0.31 for each kVAr by which the reactive demand exceeds, numerically, 0.62 times the metered demand, and will be decreased $0.31 for each kVAr by which the reactive demand is less than, numerically, 0.62 times the metered kW demand. (j) Primary service discount. For service provided and metered at 12,470/7,200 volts, where the city has such service available in the immediate area of the load and where the customer owns the necessary transformation equipment, the foregoing demand charges shall be subject to the following discount per kW of billing demand except where existing customer facilities do not meet the requirements for providing service from the city's underground network system as specified in subsection (d) of this section: $1.52. This discount is available only where the customer requesting service agrees to pay a minimum billing demand of 75 kW per month. For service provided and metered at 4,160/2,400 volts where the city has provided such service prior to October 1, 1986, and where the customer owns the necessary transformation equipment, the foregoing demand charges shall be subject to the following discount per kW of billing demand except where customer facilities do not meet the requirements for providing service from the city's underground network system as specified under character of service in subsection (d) of this section: $0.68. This discount is available only where the customer requesting service agrees to pay a minimum billing demand of 75 kW per month. Effective October 1, 1986, this discount for service provided and metered at 4,160/2,400 volts is closed to new customers and is available only to customers at existing locations. Additions to, modifications to, and upgrading of facilities at the voltage level shall be permitted at the discretion of the city. (k) Transmission service discount. For service provided and metered at transmission voltages of 115,000 volts and 230,000 volts, where the city has such service available in the immediate area of the load and where the customer owns and maintains the necessary transformation equipment, the foregoing demand charges shall be subject to the following discount per kW of billing demand: $3.05. This discount is available only where the customer requesting service agrees to pay a minimum billing demand of 10,000 kW per month. The city reserves the right to determine the feasibility of providing a new service at 115,000 volts or greater. (l) Tax adjustment. The amount computed at the monthly rate in this section as adjusted by the application of the monthly energy cost recovery shall be subject to taxes, assessments, and surcharges, imposed or assessed by any governmental authority on the basis of meters or customers or the price of or revenues from electric energy or service sold or volume of energy generated or purchased for sale or the volume of energy sold. (m) Interruption of service. The city will make reasonable provisions to ensure satisfactory and continuous service, but does not guarantee a continuous supply of electrical energy and shall not be liable for damage occasioned by interruptions of service or failure to commence delivery caused by an act of God, or the public enemy, or for any cause reasonably beyond its control, including but not limited to the failure or breakdown of generating or transmitting facilities, floods, fire, strikes or action or order of any agency having jurisdiction in the premises, or for interruptions which are necessary for inspection, repair, or changes in the generating equipment or transmission and distribution system of the city. The customer shall notify the city immediately of any defects, trouble, or accident which may in any way affect the delivery of power by the city to the customer.

(Code 1984, § 25-41; Ord. No. 90-O-0078AA, § 15, 9-12-1990; Ord. No. 92-O-0017AA, § 15, 7-7-1992; Ord. No. 93-O-0019AA, § 10, 7-13-1993; Ord. No. 94-O-0028, § 12, 7-6-1994; Ord. No. 95-O-0041, § 10, 11-21-1995; Ord. No. 96-O-0035, § 10, 12-18-1996; Ord. No. 99-O-0028, § 3, 4-28-1999; Ord. No. 01-O-10AA, § 10, 3-21-2001; Ord. No. 01-O-62, § 13, 1-23-2002; Ord. No. 06-O-23AA, § 9, 3-29-2006; Ord. No. 13-O-07, § 10, 3-27-2013; Ord. No. 14-O-42, § 10, 10-22-2014; Ord. No. 18-O-27, § 10, 9-26-2018)

Ask a question about Tallahassee law

Corpus searches the Tallahassee sections it holds and shows the ones that match, with their citations. Free, no sign-in.