§ 22-133 — Maintenance generally and safety devices for protection from refrigerant

Code of Ordinances of the Town of Cicero, Illinois (Codified through Ordinance No. 71-25, adopted September 23, 2025. (Supp. No. 122)) · Cicero Municipal Code § 22-133

Corpus is an independent public-information project, not the official City of Cicero website. Stable reference: corpuslaw.us/code/282557ea-01d1-4df7-b5ec-d03232ad0bad

Sec. 22-133. - Maintenance generally and safety devices for protection from refrigerant.

(a) Duty of person in charge. It shall be the duty of the person in charge of the premises wherein any refrigerating system is located to exercise due diligence to see that the refrigerating system is properly maintained and operated at all times. (b) Use of gas masks. Two gas helmets or masks suited to the refrigerant used shall be provided with every class A system and with every class B system that operates above atmospheric pressure, except when carbon dioxide is used. (c) Approval of gas masks. Every gas helmet or mask shall be of a type approved by the chief inspector of the department for the inspection of steam boilers, unfired pressure vessels, and cooling plants as being suitable for the refrigerant used, shall be inspected annually by the chief inspector, and shall be kept in operative condition in an easily accessible case or cabinet located outside of the entrance to the machinery room. (d) Refrigerant losses. Whenever the losses of refrigerant from a system are such as to endanger the health or lives of the human occupants of any room or structure in which such refrigeration system or any part thereof is located, it shall be the duty of the owner of such refrigeration system to apply suitable pressure or other tests to prove the system tight. (e) Charging. Every system that may be charged after installation shall have the charging connection located on its low pressure side. No container shall be left connected to a system except while charging or withdrawing refrigerant. (f) Transferring refrigerant. Refrigerants withdrawn from refrigerating systems shall be transferred to containers as prescribed by the regulations of the Interstate Commerce Commission for the transportation of such refrigerants.

(Ord. of 7-19-1948, § 5; Code 1958, § 28-5)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.