Sec. 22-140. - Indirect system installation in certain occupancies.
Indirect refrigerating systems may be installed in retail stores, restaurants, wholesale stores, beauty parlors, barbershops, offices, salesrooms, manufacturing spaces and all similar occupancies subject to the following: (1) Systems containing a nonirritant and nonflammable refrigerant may be installed in a basement or on the first floor, provided all refrigerant-containing parts of a system containing more than 100 pounds of refrigerant are installed in a machinery room having natural or mechanical means of ventilation. Such machinery room shall be equipped with tightfitting, self-closing doors. (2) Systems containing 500 pounds or less of a nonirritant and nonflammable refrigerant may be installed between the first floor and the roof, provided all refrigerant-containing parts of such system are installed in a machinery room having natural or mechanical ventilation. Such machinery room shall be equipped with tightfitting, self closing doors. (3) Systems containing more than 300 pounds of nonflammable and nonirritant refrigerant may be installed above the roof, provided all refrigerant-containing parts are located in the machinery room. All openings from such machinery room shall be made to the outside and shall not be located adjacent to the entrance or exit of any stairway, elevator shaft or fresh-air intake. (4) Systems containing an irritant or a class 1 flammable refrigerant may be installed subject to the limitations as to quantity of refrigerant and location as required for direct systems. (5) Indirect systems containing a flammable or irritant refrigerant in quantities greater than that permitted for direct systems may be installed, provided that they do not contain more than 500 pounds of refrigerant and provided, further, that all refrigerant-containing parts of the system are placed in a machinery room located on the first floor or basement. Such machinery room shall be separated from other parts of the building by solid construction having four-hour fire resistive value, and there shall be no direct means of communication between such room and other portions of the building.
(Ord. of 7-19-1948, § 26; Code 1958, § 28-14)
Ask a question about Cicero law
Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.