Sec. 22-142. - Unit systems.

(a) Unit systems may be installed subject to the limitations set forth in this section. (b) Unit systems containing an irritant or flammable refrigerant shall not be placed in the following: (1) Wards or private rooms of hospitals, sleeping quarters of asylums, cell blocks of prisons or any building where persons are confined or helpless. (2) Rooms or buildings for public assembly, for example, auditoriums, theaters, dancehalls, exhibition halls, schools (except laboratories for teaching refrigeration), courthouses, churches, and entrances and exits of business units. (3) Sleeping rooms. (c) Unit systems containing not more than six pounds of a nonflammable or nonirritant refrigerant may be installed in any location. (d) Unit systems containing more than six pounds of nonflammable and nonirritant refrigerant may be installed in any location except wards or private rooms of hospitals, sleeping quarters of asylums, or any room or building where persons are confined or helpless. (e) No unit system may be installed in any location unless the room is adequately ventilated to the outside air and unless sufficient clearance is provided to make them accessible. (f) Unit systems, unless so constructed that they will not burst due to the expansion of the refrigerant when subjected to an abnormal outside temperature, such as that created by fire, shall be protected by a pressure-relief device as follows: (1) Safety valves, if used, shall be one-fourth inch in size. (2) Rupture members, if used, shall have an opening at least 1/16 inch in diameter. (3) Fusible plugs, if used, shall have a maximum fusing point of 200 degrees Fahrenheit and a free opening of 1/16 inch in diameter. (4) Unit systems employing an air cooled condenser and containing not more than six pounds of refrigerant may have the discharge from the pressure-relief device piped into the low pressure side of the system, provided that the volume of the low pressure side of system, excluding the compressor crank case, is capable of holding the entire refrigerant charge of the system. (g) Every evaporator, unless constructed of sufficient strength to prevent injury in the ordinary and customary use thereof, shall be protected by a suitable shield to ensure protection against such injury. In all other details other than those specified in the preceding subsections of this section dealing therewith, unit systems must conform to the other sections of this Code pertaining to buildings.

(Ord. of 7-19-1948, §§ 36—42; Code 1958, § 28-16)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.