Sec. 22-138. - Buildings for public assembly.

(a) Refrigerating systems installed in rooms or buildings for public assembly, for example, auditoriums, theaters, dancehalls, exhibition halls, schools (except laboratories used for teaching refrigeration), courthouses, churches, entrances and exits of business units, and all similar occupancies, except eating places, shall be subject to the following limitations: (1) Unit systems containing a nonirritant or nonflammable refrigerant may be used in such locations. (2) Direct systems wholly confined to a kitchen may be installed, provided the system does not contain more than 20 pounds of nonirritant and nonflammable refrigerant. Such kitchen shall be equipped with tightfitting, self-closing doors and shall have natural or mechanical means of ventilation. (b) All other refrigeration in the locations listed in subsection (a) of this section must be supplied by the indirect system of refrigeration, except as permitted in those sections of this article dealing with refrigeration in connection with air conditioning with the entire refrigerant containing equipment placed in a machinery room. (c) These systems shall be subject to the following: (1) If an irritant or class 1 flammable refrigerant is used, the system shall not contain over 500 pounds of refrigerant, and the entire refrigerant-containing equipment shall be placed in a machinery room devoted to no other purpose, located on the first floor or basement. This room shall be separated from other parts of the building by solid construction having a four-hour fire resistive value and there shall be no direct means of communication between such room and any other portion of the building. The entrance or exit of such room shall be located in an outside wall, but not in a wall forming a part of the enclosure of an exit court. (2) If a class 1 or class 2 nonirritant and nonflammable refrigerant is used, the machinery room shall be provided with natural or mechanical means of ventilation directly to the outside and shall be equipped with self-closing, tightfitting doors. Such systems when installed above the first floor shall be limited in quantity to 300 pounds of refrigerant.

(Ord. of 7-19-1948, § 24; Code 1958, § 28-12)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.