For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 22-139 — Direct system installation in certain occupancies

Code of Ordinances of the Town of Cicero, Illinois (Codified through Ordinance No. 71-25, adopted September 23, 2025. (Supp. No. 122)) · Cicero Municipal Code § 22-139

Corpus is an independent public-information project, not the official City of Cicero website. Stable reference: corpuslaw.us/code/b35ed3e9-d003-494d-bd7b-0ce7118b5a2f

Sec. 22-139. - Direct system installation in certain occupancies.

Direct refrigerating systems installed in retail stores, restaurants, wholesale stores, beauty parlors, barbershops, offices, salesrooms, manufacturing spaces, and all similar occupancies shall be installed subject to the following: (1) Systems containing a class 1 nonirritant and nonflammable refrigerant shall be limited in refrigerant content to not more than one pound for each 100 cubic feet by volume in the total space, and the total refrigerant content in such system shall not exceed 2,000 pounds. (2) Systems containing a class 2 nonirritant and nonflammable refrigerant shall be limited in refrigerant content to not more than one pound for each 50 cubic feet by volume of total space, and the total refrigerant content in such systems shall not exceed 350 pounds. (3) The compressor, condenser and shell-type apparatus of systems containing more than 100 pounds of refrigerant shall be placed in a machinery room with natural or mechanical means of ventilation directly to the outside and shall be equipped with self-closing tightfitting doors. (4) Systems containing class 2 nonirritant and nonflammable refrigerant shall not be located in a space in which there is apparatus to produce an open flame, unless such space is provided with means of adequate mechanical ventilation or the apparatus for producing the open flame is vented by means of a hood so as to carry the products of decomposition to the outside atmosphere. Flames made by matches, cigarette lighters, small alcohol lamps, and similar devices shall not be considered as open flames. (5) Systems containing not more than 200 pounds of an irritant or class 1 flammable refrigerant may be installed in manufacturing portions of a commercial building normally frequented by employees only. However, when the system contains over 50 pounds of refrigerant, the compressor, condenser, and shell-type apparatus shall be placed in a machinery room with natural or mechanical ventilation and openings to other rooms to be fitted with close-fitting self-closing doors. (6) Systems containing not more than 100 pounds of an irritant or class 1 flammable refrigerant may be installed on the first floor or in the basement of buildings where the public is permitted, except commercial residential buildings. However, when systems contain over 50 pounds, the compressor, condenser, and shell-type apparatus shall be placed in a machinery room with natural or mechanical ventilation and openings to other rooms fitted with tightfitting, self-closing doors. The first floor of buildings shall have required exits opening directly out-of-doors or through corridors or other horizontal means of exit directly to an outside exit doorway. (7) Systems containing 50 pounds or less of an irritant or class 1 flammable refrigerant may be installed on any floor above the first floor of commercial buildings where the public is permitted, except that unit systems only may be used in retail stores, restaurants, and other locations where the number of employees serving the public exceed ten. (8) Systems containing 50 pounds or less of an irritant or flammable refrigerant may be installed in the basement or on the first floor only of multiple-use buildings containing dwellings; provided, however, that the compressor, condenser and shell-type apparatus of such systems containing more than 25 pounds shall be located in the machinery room. Such machinery room shall have natural or mechanical means of ventilation and shall be fitted with tightfitting, self-closing doors.

(Ord. of 7-19-1948, § 25; Code 1958, § 28-13)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.