Sec. 22-143. - Refrigerating in connection with air conditioning.

(a) Refrigerating systems used in connection with the control of temperature or humidity of air in or circulated to space occupied by people or where used for comfort cooling shall be subject to the requirements dealing therewith set forth in this section. (b) Direct systems in which the refrigerant is circulated through coils or evaporators located in the path of the air used for air conditioning may be installed for air conditioning purposes subject to the limitations set forth in the following subsections of this section. (c) Where a class 1 nonirritant and nonflammable refrigerant is used in a direct system as provided in subsection (b) of this section, the following shall apply: (1) The refrigerant content of the system shall not exceed one pound for each 100 cubic feet of volume in the total space to be cooled, and the total refrigerant content shall not exceed 2,000 pounds. (2) Noncorroding material shall be used in coils unless permanent protection against corrosion is provided. (3) Coils or coolers shall be tested to the test pressure specified for the refrigerant; provided, however, the department for the inspection of steam boilers, unfired pressure vessels, and cooling plants may accept from the manufacturers a certified copy of a test report showing that tests of the apparatus, as required by this article, were made at the place of manufacture. (d) Where a class 2 nonirritant and nonflammable refrigerant is used in a direct system as provided in subsection (b) of this section, the following shall apply: (1) The refrigerant content of the system shall not exceed one pound for each 50 cubic feet of volume of the total space to be cooled, and the total refrigerant content shall not exceed 350 pounds. (2) Any joint or connection in the refrigerant containing part of the system shall be threaded, welded, brazed, sweated or of such other type of construction as approved by the department. (3) No expansion valve or connection thereto shall be located in a ventilating system. (4) No joint or connection shall be located in air stream, except connections to coil heaters may be located in air stream, provided such connections are welded, brazed, or sweated and 1½ times the pressure specified for this refrigerant is applied in the presence of the inspector. (5) Coils or coolers shall be tested to 1½ times the test pressure specified for the refrigerant; provided, however, the department for the inspection of steam boilers, unfired pressure vessels, and cooling plants may accept from the manufacturer a certified copy of a test report showing that tests of the apparatus, as required by this article, were made at the place of manufacture. (6) Refrigerating system shall not be located in a space in which there is apparatus to produce an open flame, unless such space is provided with means of adequate mechanical ventilation or the apparatus for producing the open flame is vented by means of a hood so as to carry the products of decomposition to the outside atmosphere. Flames made by matches, cigarette lighters, small alcohol lamps, and similar devices shall not be considered as open flames. (e) Where evaporators are located in apartment or hotel rooms used for sleeping purposes or in ducts leading thereto, direct refrigerating systems for air conditioning shall be limited to 50 pounds of a class 1 or 2 nonirritant and nonflammable refrigerant, provided that the total refrigerant content of the system shall not exceed one pound for each 100 cubic feet of volume in total space to be cooled. The evaporators of such systems shall be subject to the specifications in subsections (c) and (d) of this section. (f) Where an irritant or class 1 flammable refrigerant is used in a direct system as provided in subsection (b) of this section, the system shall be limited to industrial locations and shall be subject to the following: (1) The number of employees shall not exceed one for every 200 square feet of floor area of the space to which the air is circulated. (2) The coils or evaporators shall be constructed of noncorroding materials or permanent protection against corrosion shall be provided. (3) All joints in the evaporators or connections thereto located in the air stream shall be welded and subjected to a pressure of 1½ times the test pressure specified for the refrigerant. (4) Unit coolers used in connection with air conditioning systems serving one room may be used; provided, however, that where an irritant or flammable refrigerant is used the number of workers shall not exceed one for each 150 square feet of floor area on the floors above the first or ground level. (g) Indirect systems may be installed for air conditioning subject to the following: (1) All such systems shall be subject to the limitations for institutional occupancies or industrial systems or commercial systems, as they may apply. (2) Systems in multiple dwellings shall not contain more than 350 pounds of a class 2 nonflammable and nonirritant refrigerant; provided, however, that where the system contains over 100 pounds, refrigerant-containing parts shall be placed in a machinery room with tight walls and natural or mechanical ventilation directing to the outside and with tightfitting, self-closing doors. (3) Liquids cooled by an irritant or flammable refrigerant shall not be used in a spray system to cool the air except in manufacturing units. (h) In all other details not covered by this section dealing directly therewith, refrigerating systems in connection with air conditioning must conform to other sections of this Code pertaining to buildings.

(Ord. of 7-19-1948, §§ 43—50; Code 1958, § 28-17)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.