For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-610 — International Residential Code—Section R404.4 amended

Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 5-610

Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/771def16-2388-44fa-87a1-65bad3199806

Sec. 5-610. - International Residential Code—Section R404.4 amended.

Section R404.4 of the 2018 International Residential Code is hereby amended to read as follows: R404.4 Retaining walls. Retaining walls that are not laterally supported at the top and that retain in excess of 72 inches of unbalanced fill, or retaining walls exceeding 24 inches in height that resist lateral loads in addition to soil, shall be designed in accordance with accepted engineering practice to ensure stability against overturning, sliding, excessive foundation pressure and water uplift. Retaining walls shall be designated for a safety factor of 1.5 against lateral sliding and overturning. This section shall not apply to foundation walls supporting buildings.

(Code 2018, § 5-310)

Ask a question about Lawrence law

Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.