§ 5-630 — International Residential Code—Section E3604.5.1 amended
Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 5-630
Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/7c64acce-fd7e-4730-81d3-4639cd64c53f
Sec. 5-630. - International Residential Code—Section E3604.5.1 amended.
Section E3604.5.1 of the 2018 International Residential Code is hereby amended to read as follows: E3604.5.1 Strength. Where a mast is used for support of service-drop conductors, it shall be a galvanized rigid conduit with a minimum trade size diameter of two inches. The service mast shall be of adequate strength or shall be supported by braces or guys to safely withstand the strain imposed by the service-drop or overhead service conductors. Hubs intended for use with a conduit that serves as a service mast shall be identified for use with service-entrance equipment.
(Code 2018, § 5-330)
Ask a question about Lawrence law
Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.