§ 5-637 — International Residential Code—Adding section E3902

Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 5-637

Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/acb679e1-7c96-4218-8219-5f45f8accdf7

Sec. 5-637. - International Residential Code—Adding section E3902.

The 2018 International Residential Code is hereby amended by adding section E3902, which reads as follows: E3902 General. Ground-fault circuit-interrupter protection for personnel shall be provided as required in sections E3901.2 through E3902.13. Arc-fault circuit-interrupter protection shall be provided as required by sections E3902.14 through E3902.16. Exceptions: 1. A single receptacle outlet for refrigerators, freezers, garage door openers and sump pumps located within dedicated space for each appliance that, in normal use, are not easily moved from one place to another and that are cord-and-plug connected shall be permitted to be installed in accordance with section E3909. 2. Arc-fault circuit-interrupter protection shall be permitted to be omitted from 120 volt single station smoke detectors.

(Code 2018, § 5-337)