§ 5-615 — International Residential Code—Sections N1103.3.2 (R403.3.2), N1103.3.3 (R403.3.3), and N1103.3.5 (R403.3.5) amended
Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 5-615
Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/f87e0fa8-e1ee-429d-9413-d5e9eb507be7
Sec. 5-615. - International Residential Code—Sections N1103.3.2 (R403.3.2), N1103.3.3 (R403.3.3), and N1103.3.5 (R403.3.5) amended.
Sections N1103.3.2 (R403.3.2), N1103.3.3 (R403.3.3), and N1103.3.5 (R403.3.5) of the 2018 International Residential Code are hereby amended to read as follows: N1103.3.2 (R403.3.2) Sealing (mandatory). Ducts, air handlers, and filter boxes shall be sealed. Joints and seams shall comply with either the International Mechanical Code, as adopted by the city, or section M1601.4.1, as adopted by the city, as applicable. Exception: Air-impermeable spray foam products shall be permitted to be applied without additional joint seals. N1103.3.2.1 (R403.3.2.1) Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of not greater than two percent of the design airflow rate when tested in accordance with ASHRAE 193. N1103.3.3 (R403.3.3) Duct testing (mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. Registers shall be taped or otherwise sealed during the test. 2. Post-construction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air-leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. A duct air-leakage test shall not be required for ducts serving heat or energy recovery ventilators that are not integrated with duct serving heating or cooling systems. 3. A duct air leakage test shall not be required where a whole house air leakage test is performed. A written report of the results shall be signed by the party conducting the test and provided to the building official.
(Code 2018, § 5-315)
Ask a question about Lawrence law
Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.