For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-616 — International Residential Code—Section N1103.5.1.1 (R403.5.1.1) amended

Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 5-616

Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/83399232-8f05-4564-afab-0e597c33bb50

Sec. 5-616. - International Residential Code—Section N1103.5.1.1 (R403.5.1.1) amended.

Section N1103.5.1.1 (R403.5.1.1) of the 2018 International Residential Code is hereby amended to read as follows: N1103.5.1.1 (R403.5.1.1) Circulation systems. Heated water circulation systems may be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water.

(Code 2018, § 5-316)

Ask a question about Lawrence law

Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.