Sec. 5-620. - International Residential Code—Sections M1601.1, M1601.1, and M1601.1.2 amended.

Sections M1601.1, M1601.1, and M1601.1.2 of the 2018 International Residential Code are hereby amended to read as follows: M1601.1 Duct design. Duct systems serving heating, cooling and ventilation equipment shall be installed in accordance with the provisions of this section and ACCA Manual D, the appliance manufacturer's installation instructions, or other approved methods. A drawing of each duct system, including the size and length of each duct trunk, branch, and CFM of each duct branch run, shall be on site prior to the rough-in mechanical inspection. M1601.1.1 Above-ground duct systems. Above-ground duct systems shall conform to the following: 1. Equipment connected to duct systems shall be designed to limit discharge air temperature to not greater than 250 degrees Fahrenheit (121 degrees Celsius). 2. Factory-made ducts shall be listed and labeled in accordance with UL 181 and installed in accordance with the manufacturer's instructions. 3. Fibrous glass duct construction shall conform to the SMACNA Fibrous Glass Duct Construction Standards or NAIMA Fibrous Glass Duct Construction Standards. 4. Field-fabricated and shop-fabricated metal and flexible duct constructions shall conform to the SMACNA HVAC Duct Construction Standards—Metal and Flexible except as allowed by Table M1601.1.1. Galvanized steel shall conform to ASTM A 653. 5. The use of gypsum products to construct return air ducts or plenums is permitted, provided that the air temperature does not exceed 125 degrees Fahrenheit (52 degrees Celsius) and exposed surfaces are not subject to condensation. 6. Duct systems shall be constructed of materials having a flame spread index of not greater than 200. 7. Stud wall cavities and the spaces between solid floor joists to be used as air plenums shall comply with the following conditions: 7.1 These cavities or spaces shall not be used as a plenum for supply air. 7.2 These cavities or spaces shall not be part of a required fire-resistance-rated assembly. 7.3 Multiple floors shall not utilize the same stud wall cavity to convey air. 7.4 Stud wall cavities and joist-space plenums shall be isolated from adjacent concealed spaces by tightfitting fire blocking in accordance with section R602.8. 7.5 Stud wall cavities in the outside walls of building envelope assemblies shall not be utilized as air plenums. 8. Volume dampers, equipment, and other means of supply, return, and exhaust air adjustment used in system balancing shall be provided with access. Table M1601.1.1. Duct Construction Minimum Sheet Metal Thickness for Single-Dwelling Units a Round Duct Diameter (Inches) | Static Pressure ½-Inch Water Gage | 1-Inch Water Gage Thickness (Inches) | Thickness (Inches) Galvanized | Aluminum | Galvanized | Aluminum ≤12 | 0.013 | 0.018 | 0.013 | 0.018 12 to 14 | 0.013 | 0.018 | 0.016 | 0.023 15 to 17 | 0.016 | 0.023 | 0.019 | 0.027 18 | 0.016 | 0.023 | 0.024 | 0.034 19 to 20 | 0.019 | 0.027 | 0.024 | 0.034 Rectangular Duct Dimension (Inches) | Static Pressure ½-Inch Water Gage | 1-Inch Water Gage Thickness (Inches) | Thickness (Inches) Galvanized | Aluminum | Galvanized | Aluminum ≤8 | 0.013 | 0.018 | 0.013 | 0.018 9 to 10 | 0.013 | 0.018 | 0.016 | 0.023 11 to 12 | 0.016 | 0.023 | 0.019 | 0.027 13 to 16 | 0.019 | 0.027 | 0.019 | 0.027 17 to 18 | 0.019 | 0.027 | 0.024 | 0.034 19 to 20 | 0.024 | 0.034 | 0.024 | 0.034 For SI: one inch = 25.4 mm, one inch water gage = 249 Pa. a Ductwork that exceeds 20 inches by dimension or exceeds a pressure of one inch water gage (250 Pa) shall be constructed in accordance with SMACNA HVAC Duct Construction Standards Metal and Flexible. M1601.1.2 Underground duct systems. Underground duct systems shall be constructed of approved concrete, clay, metal or plastic. The maximum design temperature for systems utilizing plastic ducts and fittings shall be 150 degrees Fahrenheit (66 degrees Celsius). Metal ducts shall be completely encased in concrete not less than two inches (51 mm) thick. Nonmetallic ducts shall be installed in accordance with the manufacturer's instructions. Plastic pipe and fitting materials shall conform to cell classification 12454-B of ASTM D 1248 or ASTM D 1784 and external loading properties of ASTM D 2412. Ducts shall slope to drainage point that has access. Where encased in concrete, ducts shall be sealed and secured prior to any concrete being poured. Metallic ducts having an approved protective coating and nonmetallic ducts shall be installed in accordance with the manufacturer's instructions.

(Code 2018, § 5-320)

Ask a question about Lawrence law

Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.