§ 5-634 — International Residential Code—Table E3801.4 amended

Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 5-634

Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/0048f1a8-07e8-4378-a514-1fd9def2c7a6

Sec. 5-634. - International Residential Code—Table E3801.4 amended.

Table E3801.4, Allowable Applications for Wiring Methods, of the 2018 International Residential Code is hereby amended to read as follows: Table E3801.4 (Chapter 3 and 300.2). Allowable Applications for Wiring Methods a, b, c, d, e, f, g, h, i, j, k Allowable Applications (applications allowed where marked with an A) | AC | EMT | ENT | FMC | IMC RMC RNC | LFC a | MC | NM | SR | SE> | UF | USE Services | — | A h | A | A i | A | A i | A | — | — | — | — | — Feeders | A | A | A | A | A | A | A | A | — | A b | A | A b Branch-circuits | A | A | A | A | A | A | A | A | A | A c | A | — Inside a building | A | A | A | A | A | A | A | A | A | A | A | — Wet locations exposed to sunlight | — | A | A h | A d | A | A | A | — | — | A | A e | A e Damp locations | — | A | A | A d | A | A | A | — | — | A | A | A Embedded in non-cinder concrete in dry location | — | A | A | — | A | — | — | — | — | — | — | — In non-cinder concrete in contact with grade | — | A f | A | — | A f | — | — | — | — | — | — | — Embedded in plaster not exposed to dampness | A | A | A | A | A | A | A | — | — | A | A | A Embedded in masonry | — | A | A | — | A f | A | A | — | — | — | — | — In masonry voids and cell exposed to dampness or below grade line | — | A f | A | A d | A f | A | A | — | — | A | A | — Fished in masonry voids | A | — | — | — | — | — | — | — | — | — | — | — In masonry voids and cells not exposed to dampness | A | A | A | A | A | A | A | A | A | A | A | A Run exposed | A | A | A | A | A | A | A | A | A | A | A | A Run exposed and subject to physical damage | — | — | — | — | A g | — | — | — | — | — | — | — For direct burial | — | A f | — | — | A f | A | A | — | — | — | — | A For SI: one foot = 304.8 mm. a Liquid-tight flexible nonmetallic conduit without integral reinforcement within the conduit wall shall not exceed six feet in length. b Type use cable shall not be used inside buildings. c The grounded conductor shall be insulated except where used to supply other buildings on the same premises. d Conductors shall be a type approved for wet locations and the installation shall prevent water from entering other raceways. e Shall be listed as "Sunlight Resistant." f Metal raceways shall be protected from corrosion and approved for the application. Aluminum RNC requires approved supplementary corrosion protection. g RNC shall be Schedule 80. h Shall be listed as "Sunlight Resistant" where exposed to the direct rays of the sun. i Conduit shall not exceed six feet in length. j Liquid-tight flexible nonmetallic conduit is permitted to be encased in concrete where listed for direct burial and only straight connectors listed for use with LFNC are used. k In wet locations under any of the following conditions: (i) The metallic covering is impervious to moisture. (ii) A lead sheath or moisture-impervious jacket is provided under the metal covering. (iii) The insulated conductors under the metallic covering are listed for use in wet locations and a corrosion-resistant jacket is provided over the metallic sheath.

(Code 2018, § 5-334)

Ask a question about Lawrence law

Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.