Sec. 5-614. - International Residential Code—Section N1102.4.1.2 (R402.4.1.2) amended.
Section N1102.4.1.2 (R402.4.1.2) of the 2018 International Residential Code is hereby amended to read as follows: N1102.4.1.2 (R402.4.1.2) Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding five air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones three through 8. Testing shall be conducted in accordance with RESNET/ICC 380, ASTM E 779 or ASTM E 1827 and reported at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the building official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the building official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weather-stripping or other infiltration control measures. 2. Dampers, including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, where installed at the time of the test, shall be open. 4. Exterior or interior terminations for continuous ventilation systems shall be sealed. 5. Heating and cooling systems, where installed at the time of the test, shall be turned off. 6. Supply and return registers, where installed at the time of the test, shall be fully open. Exception: When all reasonable efforts by an approved third party have failed to reach three air changes per hour in Climate Zone 4 a written report of the efforts and results shall be signed by the party conducting the work and provided to the building official. The building official may administratively approve up to 3½ maximum air changes per hour.
(Code 2018, § 5-314)
Ask a question about Lawrence law
Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.