§ 5-706 — National Electrical Code—Section 210.8 amended
Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 5-706
Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/66a5567d-d744-4a26-8017-49e2c84dcba2
Sec. 5-706. - National Electrical Code—Section 210.8 amended.
Section 210.8 of the NPFA 70, National Electrical Code, 2017 edition, is hereby amended to read as follows: 210.8 Ground-fault circuit-interrupter protection for personnel. Ground-fault circuit-interrupter protection for personnel shall be provided as required in 210.8(A) through (D). The ground-fault circuit-interrupter shall be installed in a readily accessible location. Informational note No. 1: See 215.9 for ground-fault circuit-interrupter protection for personnel on feeders. Informational note No. 2: See 422.5(A) for GFCI requirements for appliances. For the purposes of this section, when determining distance from receptacles, the distance shall be measured as the shortest path of the cord of the appliance connected to the receptacle would follow without piercing a floor, wall, ceiling, or fixed barrier, or passing through a door, doorway, or window. (A) Dwelling units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (9) shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms. (2) Garages, and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use. Exception to (2): A single receptacle outlet for refrigerators, freezers, garage door openers, and sump pumps located within dedicated space for each appliance that, in normal use, are not easily moved from one place to another and that are cord-and-plug connected shall be permitted to be installed in accordance with 400.7(A)(6), (A)(7), or (A)(8). (3) All outdoors. Exception to (3): Receptacles that are not readily accessible and are supplied by a branch-circuit dedicated to electric snow-melting, or deicing, shall be permitted to be installed in accordance with 426.28, as applicable. (4) Crawlspaces—at or below grade level. (5) Unfinished portions or areas of the basement not intended as habitable rooms. Exception Nos. (1) to (5): A single receptacle outlet for refrigerators, freezers, garage door openers, and sump pumps located within dedicated space for each appliance that, in normal use, are not easily moved from one place to another and that are cord-and-plug connected shall be permitted to be installed in accordance with 400.7(A)(6), (A)(7), or (A)(8). Exception Nos. (2) to (5): A receptacle supplying only a permanently installed fire alarm or burglar alarm system shall not be required to have ground-fault circuit-interrupter protection. Informational note: See 760.41(B) and 760.121(B) for power supply requirements for fire alarm systems. Receptacles installed under the exception to 210.8(A)(5) shall not be considered as meeting the requirements of 210.52 (G). (6) Kitchens, where the receptacles are installed to serve the countertop surfaces. (7) Sinks and washing machines, where receptacles are installed within 1.8 m (six feet) of the outside edge of the sink and tub of the washing machine. Exception to (7): A single receptacle outlet for appliances located within dedicated space for each appliance that, in normal use, are not easily moved from one place to another and that are cord-and-plug connected shall be permitted to be installed in accordance with 400.7(A)(6), (7), or (8), including microwaves, ovens, ice makers, warming ovens, dryers, washing machines, and garbage disposals. (8) Boathouses. (9) Bathtubs or shower stalls, where receptacles are installed within 1.8 m (six feet) of the outside edge of the bathtub or shower stall. (B) Other than dwelling units. All single-phase receptacles rated 150 volts to ground or less, 50 amperes or less and three-phase receptacles rated 150 volts to ground or less, 100 amperes or less installed in the following locations shall have a ground-fault circuit-interrupter protection for personnel: (1) Bathrooms. (2) Kitchens. (3) Rooftops. Exception: Receptacles on rooftops shall not be required to be readily accessible other than from the rooftop. (4) Outdoors. Exception Nos. (1) to (3) and (4): Receptacles that are not readily accessible and are supplied by a branch-circuit dedicated to electric snow-melting, or deicing shall be permitted to be installed in accordance with 426.28, as applicable. Exception Nos. (2) to (4): In industrial establishments only, where the conditions of maintenance and supervision ensure that only qualified personnel are involved, an ensured equipment grounding conductor program as specified in 590.6(B)(2) shall be permitted for only those receptacle outlets used to supply equipment that would create a greater hazard if power is interrupted or having a design that is not compatible with GFCI protection. (5) Sinks, where receptacles are installed within 1.8 m (six feet) from the top inside edge of the bowl of the sink. Exception Nos. (1) to (5): In industrial laboratories, receptacles used to supply equipment where removal of power would introduce a greater hazard shall be permitted to be installed without GFCI protection. Exception Nos. (2) to (5): For receptacles located in patient bed locations of general care or critical care areas of health care facilities other than those covered under 210.8(B)(1), GFCI protection shall not be required. (6) Indoor wet locations. (7) Locker rooms with associated showering facilities. (8) Garages, service bays, and similar areas other than vehicle exhibition halls and showrooms. (9) Crawlspaces, at or below grade level. (10) Unfinished portions or areas of the basement not intended as habitable rooms. (C) Boat hoists. GFCI protection shall be provided for outlets not exceeding 240 volts that supply boat hoists installed in dwelling unit locations. (D) Crawlspace lighting outlets. GFCI protections shall be provided for lighting outlets not exceeding 12.0 volts installed in the crawlspaces.
(Code 2018, § 5-406)
Ask a question about Lawrence law
Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.