Sec. 5-707. - National Electrical Code—Section 210.12 amended.
Section 210.12 of the NPFA 70, National Electrical Code, 2017 edition, is hereby amended to read as follows: 210.12 Arc-fault circuit-interrupter protection. Arc-fault circuit-interrupter protection shall be provided as required in 201.12(A), (B), and (C). The arc-fault circuit-interrupter shall be installed in a readily accessible location. (A) Dwelling units. All 120-volt, single phase, 15- and 20-ampere branch-circuits supplying outlets or devices installed in dwelling unit family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar rooms or areas shall be protected by any of the means described in 210.12(A)(1) through (6): (1) A listed combination-type arc-fault circuit-interrupter installed to provide protection of the entire branch-circuit. (2) A listed branch/feeder type AFCI installed at the origin of the branch-circuit in combination with a listed outlet branch-circuit type arc-fault circuit-interrupter installed at the first outlet box on the branch-circuit. The first outlet box in the branch-circuit shall be marked to indicate that it is the first outlet of the circuit. (3) A listed supplemental arc protection circuit breaker installed at the origin of the branch-circuit in combination with a listed outlet branch-circuit type arc-fault circuit-interrupter installed at the first outlet box on the branch-circuit where all of the following conditions are met: a. The branch-circuit wiring shall be continuous from the branch-circuit overcurrent device to the outlet branch-circuit arc-fault circuit-interrupter. b. The maximum length of the branch-circuit wiring from the branch-circuit overcurrent device to the first outlet shall not exceed 15.2 m (50 feet) for a 14 AWG conductor or 21.3 m (70 feet) for a 12 AWG conductor. c. The first outlet box in the branch-circuit shall be marked to indicate that it is the first outlet of the circuit. (4) A listed outlet branch-circuit type arc-fault interrupter installed at the first outlet on the branch-circuit in combination with a listed branch-circuit overcurrent protective device where all of the following conditions are met: a. The branch-circuit wiring shall be continuous from the branch-circuit overcurrent device to the outlet branch-circuit arc-fault circuit-interrupter. b. The maximum length of the branch-circuit wiring from the branch-circuit overcurrent device to the first outlet shall not exceed 15.2 m (50 feet) for a 14 AWG conductor or 21.3 m (70 feet) for a 12 AWG conductor. c. The first outlet box in the branch-circuit shall be marked to indicate that it is the first outlet of the circuit. d. The combination of the branch-circuit overcurrent device and the outlet branch-circuit AFCI shall be identified as meeting the requirements for a system combination-type AFCI and shall be listed as such. (5) If RMC, IMC, EMT, Type MC, or steel armored Type AC cables meeting the requirements of 250.118, metal wire ways, metal auxiliary gutters, and metal outlet and junction boxes are installed for the portion of the branch-circuit between the branch-circuit overcurrent device and the first outlet, it shall be permitted to install a listed branch-circuit Type AFCI at the first outlet to provide protection for the remaining portion of the branch-circuit. (6) Where a listed metal or nonmetallic conduit or tubing or Type MC cable is encased in not less than 50 mm (two inches) of concrete for the portion of the branch-circuit between the branch-circuit overcurrent device and the first outlet, it shall be permitted to install an outlet branch-circuit Type AFCI at the first outlet to provide protection for the remaining portion of the branch-circuit. Exception No. 1: Where an individual branch-circuit to a fire alarm system installed in accordance with 760.41(B) or 760.121(B) is installed in RMC, IMC, EMT, or steel-sheathed cable, Type AC or Type MC, meeting the requirements of 250.118, with metal outlet and junction boxes, AFCI protection shall be permitted to be omitted. Exception No. 2: ACFI protection shall be permitted to be omitted from 120-volt single-station smoke detectors. Informational note No. 1: For information on combination-type and branch/feeder-type arc-fault circuit-interrupters, see U.L. 1699-2011, Standard for Arc-Fault Circuit Interrupters. For information on outlet branch-circuit type arc-fault circuit-interrupters, see U.L. Subject 1699A, Outline of Investigation for Outlet Branch-circuit Arc-Fault Circuit-Interrupters. For information on system combination AFCIs, see UL Subject 1699C, Outlet of Investigation for System Combination Arc-Fault Circuit Interrupters. Informational note No. 2: See 29.6.3(5) of the NFPA 72-2013, National Fire Alarm and Signaling Code, for information related to secondary power-supply requirements for smoke alarms installed in dwelling units. Informational note No. 3: See 760.41(B) and 760.121(B) for power-supply requirements for fire alarm systems. (B) Dormitory units. All 120-volt, single-phase, 15- and 20-ampere branch-circuits supplying outlets and devices installed in dormitory unit bedrooms, living rooms, hallways, closets, bathrooms, and similar rooms shall be protected by any of the means described in 210.12(A)(1) through (6). (C) Guest rooms and guest suites. All 120-volt, single-phase, 15- and 20-ampere branch-circuits supplying outlets and devices installed in guest rooms and guest suites of hotels and motels shall be protected by any of the means described in 210.12(A)(1) through (6). (D) Branch-circuit extensions or modifications, dwelling units and dormitory units. In any of the areas specified in 210.12(A) or (B), where branch-circuit wiring is modified, replaced, or extended, the branch-circuit shall be protected by one of the following: (1) A listed combination Type AFCI located at the origin of the branch-circuit (2) A listed outlet branch-circuit Type AFCI located at the first receptacle outlet of the existing branch-circuit. Exception: AFCI protection shall not be required where the extension of the existing conductors is not more than 1.8 m (six feet) and does not include any additional outlets or devices.
(Code 2018, § 5-407)
Ask a question about Lawrence law
Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.