§ 5-720 — National Electrical Code—Section 362.10 amended
Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 5-720
Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/7c5f2a34-5f67-451d-87d8-41877334adea
Sec. 5-720. - National Electrical Code—Section 362.10 amended.
Section 362.10 of the NPFA 70, National Electrical Code, 2017 edition, is hereby amended to read as follows: 362.10 Uses permitted. For the purpose of this article, the first floor of a building shall be that floor that has 50 percent or more of the exterior wall surface area level with or above finished grade. One additional level that is the first level and not designed for human habitation and used only for vehicle parking, storage, or similar use shall be permitted. The use of ENT and fittings shall be permitted in the following: (1) In any building not exceeding three floors above grade as follows: a. For exposed work, where not prohibited by 362.12. b. Concealed within walls, floors, and ceilings. (2) In any building exceeding three floors above grade, ENT shall be concealed within walls, floors, and ceilings where the walls, floors, and ceilings provide a thermal barrier of material that has at least a 15-minute finish rating as identified in listings of fire-rated assemblies. The 15-minute-finish-rated thermal barrier shall be permitted to be used for combustible or noncombustible walls, floors, and ceilings. Exception to (2): Where a fire sprinkler system is installed in accordance with NFPA 13-2013, Standard for the Installation of Sprinkler Systems, on all floors, ENT shall be permitted to be used within walls, floors, and ceilings, exposed or concealed, in buildings exceeding three floors above grade. Informational note: A finish rating is established for assemblies containing combustible (wood) supports. The finish rating is defined as the time at which the wood stud or wood joist reaches an average temperature rise of 121 degrees Celsius (250 degrees Fahrenheit) or an individual temperature of 163 degrees Celsius (325 degrees Fahrenheit) as measured on the plane of the wood nearest the fire. A finish rating is not intended to represent a rating for a membrane ceiling. (3) In locations subject to severe corrosive influences as covered in 300.6 and where subject to chemicals for which the materials are specifically approved. (4) In concealed, dry, and damp locations not prohibited by 362.12. (5) Encased in poured concrete, or embedded in a concrete slab on grade where ENT is placed on sand or approved screenings, provided fittings identified for this purpose are used for connections. (6) For wet locations indoors as permitted in this section or in a concrete slab on or below grade, with fittings listed for the purpose. (7) Metric designator 16 through 27 (trade size one-half through one) as listed manufactured prewired assembly. Informational note: Extreme cold may cause some types of nonmetallic conduits to become brittle and therefore more susceptible to damage from physical contact. (8) Conductors or cables rated at a temperature higher than the listed temperature rating of ENT shall be permitted to be installed in ENT, if the conductors or cables are not operated at a temperature higher than the listed temperature rating of the ENT.
(Code 2018, § 5-420)
Ask a question about Lawrence law
Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.
