Sec. 5-708. - National Electrical Code—Section 210.23 amended.
Section 210.23 of the NPFA 70, National Electrical Code, 2017 edition, is hereby amended to read as follows: 210.23 Permissible loads, multiple-outlet branch-circuits. In no case shall the load exceed the branch-circuit ampere rating. A branch-circuit supplying two or more outlets or receptacles shall supply on the loads specified according to its size as specified in 210.23(A) through (D) and as summarized in 210.24 and Table 210.24. (A) 15- and 20-ampere branch-circuits. A 15- or 20-ampere branch-circuit shall be permitted to supply lighting units or other utilization equipment, or a combination of both, and shall comply with 210.23(A)(1), (2), and (3). Exception: The small appliance branch-circuits, laundry branch-circuits, and bathroom branch-circuits required in a dwelling unit by 210.11(C)(1), (2), and (3) shall supply only the receptacle outlets specified in that section. (1) Cord-and-plug-connected equipment not fastened in place. The rating of any one cord-and-plug-connected utilization equipment not fastened in place shall not exceed 80 percent of the branch-circuit ampere rating. (2) Utilization equipment fastened in place. The total rating of utilization equipment fastened in place, other than luminaries, shall not exceed 50 percent of the branch-circuit ampere rating where lighting units, cord-and-plug-connected utilization equipment not fastened in place, or both, are also supplied. (3) Sump pumps. Sump pumps shall be served by an individual branch-circuit. The circuit and its single receptacle outlet shall be in addition to any outlets required by 210.52. (B) 30-ampere branch-circuits. A 30-ampere branch-circuit shall be permitted to supply fixed lighting units with heavy-duty lamp holders in other than a dwelling units or utilization equipment in any occupancy. A rating of any one cord-and-plug-connected utilization equipment shall not exceed 80 percent of the branch-circuit ampere rating. (C) 40- and 50-ampere branch-circuits. A 40- or 50-ampere branch-circuit shall be permitted to supply cooking appliances that are fastened in place in any occupancy. In other than dwelling units, such circuits shall be permitted to supply fixed lighting units with heavy-duty lamp holders, infrared heating units, or other utilization equipment. (D) Branch-circuits larger than 50 amperes. Branch-circuits larger than 50 amperes shall supply only non-lighting outlet loads.
(Code 2018, § 5-408)
Ask a question about Lawrence law
Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.