Sec. 5-717. - National Electrical Code—Section 250.68 amended.

Section 250.68 of the NPFA 70, National Electrical Code, 2017 edition, is hereby amended to read as follows: 250.68 Grounding electrode conductors and bonding jumper connection to grounding electrodes. The connection of a grounding electrode conductor at the service, at each building or structure where supplied by a feeders or branch-circuits, or at a separately derived system and associated bonding jumpers shall be made as specified 250.68(A) through (C). (A) Accessibility. All mechanical elements used to terminate a grounding electrode conductor or bonding jumper to a grounding electrode shall be accessible. The location of the grounding electrode conductor connection to the grounding electrodes shall be permanently stated on a plaque or directory on the service disconnecting means. Exception No. 1: An encased or buried connection to a concrete-encased, driven, or buried grounding electrode shall not be required to be accessible. Exception No. 2: Exothermic or irreversible compression connections used at terminations, together with the mechanical means used to attach such terminations to fireproofed structural metal whether or not the mechanical means is reversible, shall not be required to be accessible. (B) Effective grounding path. The connection of a grounding electrode conductor or bonding jumper to a grounding electrode shall be made in a manner that will ensure a permanent and effective grounding path. Where necessary to ensure the grounding path for a metal piping system used as a grounding electrode, bonding shall be provided around insulated joints and around any equipment likely to be disconnected for repairs or replacement. Bonding jumpers shall be of sufficient length to permit removal of such equipment while retaining the integrity of the grounding path. (C) Grounding electrode connections. Grounding electrode conductors and bonding jumpers shall be permitted to be connected to the following locations and used to extend the connection to an electrode: (1) Interior metal water piping located not more than 1.52 m (five feet) from the point of entrance to the building shall be permitted to be used as a conductor to interconnect electrodes that are part of the grounding electrode system. Exception: In industrial, commercial, and institutional buildings or structures, if conditions of maintenance and supervision ensure that only qualified persons service the installation, interior metal water piping located more than 1.52 m (five feet) from the point of entrance to the building shall be permitted as a bonding conductor to interconnect electrodes that are part of the grounding electrode system, or as a grounding electrode conductor, if the entire length, other than short sections passing perpendicularly through walls, floors, and ceilings, of the interior metal water pipe that is being used for the conductor is exposed. (2) The metal structural frame of a building shall be permitted to be used as a conductor to interconnect electrodes that are part of the grounding electrode system, or as a grounding electrode conductor. (3) A concrete-encased electrode of either the conductor type, reinforcing rod or bar installed in accordance with section 250.52(A)(3) extended from its location within the concrete to an accessible location above the concrete shall be permitted.

(Code 2018, § 5-417)

Ask a question about Lawrence law

Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.